Teledyne LeCroy - High Voltage Passive Probes
More Product Information
-
Fast GigE Vision InGaAs SWIR camera
-
VGA resolution
-
Power over Ethernet
-
Compact industrial design, no fan
-
Up to 303 fps at full resolution
-
GigE Vision interface with Power over Ethernet
-
Comprehensive I/O control options
-
Automated on-board image correction
-
Stabilized sensor cooling, no fan
-
Extended operating temperature range
-
2500VA, 2000W, Wide Range 50/60Hz Input and 120VAC 60Hz Output, Double Conversion, On-Line, High Temperature, Isolated, Rugged UPS with Power Factor Correction for Military Applications
-
High power density / low ripple and noise
-
High programming resolution with Ethernet interface
-
Constant voltage and current mode
-
Remote sensing
-
Isolated analog control and monitoring (optional)
-
1500VA, 1050W Global 120/230VAC Input 120VAC 60Hz Output, Isolated High Temp, Rack Mount UPS
Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ohm) to 5 kOhm), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 MOhm) input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz.
-
Precise programming of voltage and current slew rate for sensitive loads.
-
Modules within one chassis can be connected to different loads and controlled independently.
-
Industrial field bus interface (Modbus-TCP, Modbus-RTU, Ethernet/IP (Industrial Protocol)) enable real-time digital control.
-
Built-in energy meter calculates the delivered energy throughout a process or period of time.
-
Optional real time clock enables accurate timestamping of events.
-
Built in power quality monitoring detects and saves input voltage anomalies which can be saved for later diagnostic analysis.
-
Programmable analog interface scaling facilitates incorporating the ASD to existing systems with minimal effort.
-
Load impedance measurement, including rate-of-change calculations, enable load "state of health" monitoring and implementation of system preventive maintenance algorithms
-
Programmable filter bandwidth of the output voltage, current and power monitors let the user accommodate their response speed to particular needs.
-
Full featured GUI (Graphical User Interface) helps to test and debug the system by communicating with the power supply in real time.
-
1500VA, 1050W High Temperature Double Conversion On-Line Global Input UPS with 120VAC, 60Hz Output and Power Factor Correction.
-
100 MHz, 200 MHz, 350 MHz, 500 MHz and 1 GHz bandwidths
-
Up to 4 GS/s sample rate
-
Long Memory – up to 20 Mpts
-
10.1” capacitive touch screen display
-
16 Digital Channel MSO option
-
MAUI - Most Advanced User Interface
-
Designed for Touch
-
Built for Simplicity
-
Made to Solve
-
-
Advanced Anomaly Detection
-
Fast Waveform Update
-
History Mode - Waveform Playback
-
WaveScan - Search and Find
-
-
Multi-Instrument Capabilities
-
Protocol Analysis - Serial Trigger and Decode
-
Waveform Generation - Built-in Function Generator
-
Digital Voltmeter and Frequency Counter
-
-
Future Proof
-
Upgradeable Bandwidth
-
Field Upgradable Software and Hardware Options
-
Teledyne LeCroy
Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively.
Oscilloscopes are tools used by designers and engineers to measure and analyze complex electronic signals in order to develop high-performance systems and to validate electronic designs in order to improve time to market. Protocol analyzers are tools used by designers and engineers to generate and monitor traffic over high speed serial data interfaces, including DDR, PCI Express, Fibre Channel, Serial ATA, SAS, USB and others. Both products are critical in the development of a wide variety of demanding design applications.
We utilize both of these important product areas in combination to tackle the most demanding serial data test applications, offering tailored solutions to help our customers perfect their chips, interfaces, subsystems and products which utilize these important communications standards. With the explosion in the use of serial data communications technologies in semiconductors, between devices on circuit boards and between computers and peripherals, we are aimed at a growing and important market.
Our oscilloscopes offer a powerful combination of large and informative displays combined with advanced waveshape analysis capabilities typically tailored to enhance the productivity of engineers in specific applications areas such as serial data test, disk drive test and automotive bus analysis.
Headquartered in Chestnut Ridge, New York, LeCroy has sales, service and development subsidiaries in the US and throughout Europe and Asia. LeCroy products are employed across a wide variety of industries, including semiconductor, computer, consumer electronics, military/aerospace, automotive/industrial, and telecommunications.
Contact Details
Headquarters Teledyne LeCroy
700 Chestnut Ridge Road, Chestnut Ridge, NY 10977-6499, USA
Phone: 800-553-2769 or 845-425-2000
Phone Support: 1-800-553-2769
Fax Sales: 845-578-5985
Email Sales: contact.corp@teledynelecroy.com
Email Support: support@teledynelecroy.com (Oscilloscopes, Waveform Generators, Signal Integrity)