Products

Displaying 1 - 11 of 11
The VectorStar ME7838 Series broadband VNA offers the widest available single frequency sweep from 70 kHz to 110, (ME7838AX to 125), (ME7838EX to 125), to 145 GHz, and to 220 GHz with mmWave bands to 1.1 THz. 
The VectorStar ME7838x4 broadband system VNA offers the widest available 4-port single sweep measurements from 70 kHz to 110, 125, 145, and 150 GHz with mmWave bands up to 1.1 THz
2-port VNA with frequency options from 1 MHz to 8 GHz / 20 GHz / 43.5 GHz (options for 20, 50, and 100 meters) Extend remote ports 100 meters apart with PhaseLync synchronization Small and lightweight ports enable direct connection to DUT eliminating long cable runs Guaranteed performance to 43.5 GHz with Extended-K™ ports PC control takes advantage of external computer processing power and functionality No on-board data storage makes use in secure applications more convenient Common ShockLine control software delivers powerful debug and test capabilities PhaseLync control module MN25132A
1-port VNA with frequency options from 150 kHz to 6 GHz External PC control enables control of multiple ShockLine MS46121B devices in parallel for excellent multisite throughput Very compact package allows for direct connection to the DUT Scalar transmission measurements in a (1-to-1) or (1-to-n) configuration No on-board data storage eliminates the need for data purging in secure applications Standard bandpass time domain with time gating enables easier and faster fault identification A common GUI interface within the ShockLine family reduces switching costs between models
Guaranteed performance to 43.5 GHz with Extended K™ ports PC control takes advantage of external computer processing power and functionality Compact 1U high package for efficient use of bench and rack space No on-board data storage eliminates the need for data purging in secure applications Time domain with time gating option enables easier and faster fault identification A common GUI interface within the ShockLine family reduces switching costs between models Universal Fixture Extraction (UFX) software option provides advanced de-embedding tools for test fixture extraction
1-port VNA with frequency options from 1 MHz to 8 GHz / 20 GHz / 43.5 GHz Guaranteed performance to 43.5 GHz with Extended-KTM ports PC control takes advantage of external computer processing power and functionality Small and lightweight package enables direct connection to the DUT No on-board data storage eliminates the need for data purging in secure applications All ShockLine VNAs share common software supporting GUI and program compatibility Time domain with time gating option enables easier and faster fault identification Simultaneous Sweep enabling users to operate multiple (up to four) MS46131A VNAs concurrently in independent software instances, unlocking true parallel measurement execution
Guaranteed performance to 43.5 GHz with Extended K™ ports Ideal for testing RF and microwave devices, mmWave antennas, and other passive 5G components Fast sweep speed and wide dynamic range minimize test times and maximize throughput Excellent corrected directivity allows for less measurement uncertainty Time domain with time gating option grants easier and faster fault identification Industry-standard LAN interface for remote control is more robust than USB and faster than GPIB Standard removable hard drive provides additional security for military and government research users A common GUI and SCPI interface within the ShockLine family
SPA available from 70KHz to 20/40/70/110/125/145 and 220GHz. Also available for banded configuration to 1.1THz. Dual SPA mode available: suitable for Mixers/Amplifier/ Harmonics /Spurious testing. SPA available on all ports. User can define which port to use as SPA port. Several detection types available in classical mode: Peak, minimum, RMS, Mean. Various math functions can be applied on SPA mode like Min hold/max hold/ user defined equations. Sources and receivers can be independently configured. Can be used as Tracking Generator. For units that have a dual source, a dual drive option is available. Support for external source control also possible.
Guaranteed performance to 43.5 GHz with Extended K™ ports High output power allows measurement of high attenuation devices Wide dynamic range enables measurement of very low reflection artifacts Excellent corrected directivity minimizes measurement uncertainty SmartCal™ auto calibration unit reduces calibration and setup time Time domain with time gating option grants easier and faster fault identification Modern LAN interface for remote control is faster than GPIB A common GUI and SCPI interface within the ShockLine family Bias tee option simplifies test setups where the DUT needs DC biasing
Specified performance to 43.5 GHz with Extended K™ ports Simple signal integrity testing of passive multiport and differential devices Wide dynamic range enables measurement of very low reflection artifacts Excellent corrected directivity minimizes measurement uncertainty SmartCal™ auto calibration unit reduces calibration and setup time Time domain with time gating option enables TDR-like measurements Modern LAN interface for remote control is faster than GPIB A common GUI and SCPI interface within the ShockLine family The compact 3U high chassis allows for the efficient use of rack space Bias tee option simplifies test setups where the DUT needs DC biasing
Vector Network Analyzer Frequency Range from 10 MHz up to 3.2 GHz Spectrum Analyzer Frequency Range from 9 kHz up to 3.2 GHz -156 dBm/Hz Displayed Average Noise Level (Typ.) -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.) Total Amplitude Accuracy < 1.2 dB 1 Hz Minimum Resolution Bandwidth (RBW) All-Digital IF Technology Standard Preamplifier Distance to fault capability using VNA time domain analysis Up to 1.5 GHz Tracking Generator Kit Built-in Advanced Measurement capability (CHP, ACPR, OBW, CNR, TOI, etc) 10.1 lnch WVGA (1024 x 600) Display