Test & Measurement
Download Line Card
Document
Products
Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
Easy to Use
-
No need to break the circuit or insert a shunt
-
Small form factors for use on crowded boards
-
-
Variety of Applications
-
Bandwidths up to 100 MHz
-
Peak currents up to 700 A
-
Sensitivities down to 1mA/div
-
-
High Precision Measurements
-
Low frequency accuracy of 1%
-
Integrated autozero capability
-
-
Fully Integrated with Teledyne LeCroy Oscilloscope
-
No additonal hardware is required
-
Power is supplied from oscilloscope ProBus connection
-
Automatic display of waveforms in Amps and calculated power traces scaled correctly in Watts
-
Degauss and Autozero directly from oscilloscope user interface
-
-
DCS025 Deskew Calibration Source
-
Provides ability to precisely deskew most voltage probes along with 30, 150 and 500A current probes
-
-
Full control from oscilloscope through ProBus interface
-
Dc to 100 MHz bandwidth
-
Outstanding 100,000: 1 Common Mode Rejection Ratio (CMRR)
-
Gain of x1 or x10
-
Industry-leading overdrive recovery
-
Low noise
-
Selectable BW limiting
-
Two gain control modes when connected to a Teledyne LeCroy oscilloscope
-
Built-in precision Voltage Generator (PVG)
-
Comparator and true differential offset modes
Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point
-
Highest resolution - HD4096 Technology, 12 bits all the time
-
Bigger Display, smaller footprint, most bench space
-
More capability, increased productivity
High voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
High voltage probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are several fixed-attenuation probes covering a range from 1 kV to 6 kV and varying transient overvoltage ratings. All of these high voltage probes feature a spring loaded probe tip and a variety of standard accessories to make probing high voltages safe and easy. Additionally, all of the high voltage probe have a probe sense pin to automatically configure the oscilloscope for use with the probe.
-
1 kV CAT safety rated
-
Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
-
1% gain accuracy
-
High offset capability at both high and low attenuation
-
AC or DC coupling
-
ProBus active probe interface with automatic scaling
-
Auto-zero capabilities
-
Wide oscilloscope compatibility