High dispersion for reflective surfaces and shorter working distances.
-
Provides a narrower and less intense illumination area than the AL116.
-
IP65 compliant washdown option is available, as are a wide spectrum of wavelengths.
-
Available with polarization and diffusion light conditioning.
-
This expandable compact bar light is pre-engineered for custom lengths in 2″ increments up to 40″.
California Instruments - Ls-Lx Series 3kVA - 18kVA Three Phase and Single Phase AC Power Source
-
Backward Compatible with L Series
-
Function and bus compatible with the California Instruments L Series
-
-
Three phase and Single phase modes
-
Ideally suited for avionics and defense applications
-
-
3 KVA to 18 KVA Power Levels
-
Match power source and cost to application requirements
-
-
Transient Programming
-
Test products for susceptibility to AC line disturbances
-
-
Built-in Measurements
-
Performs voltage, current, and power measurements
-
-
Advanced Features
-
Arbitrary waveform generation, harmonic analysis, GPIB interface are some of the available options
-
-
Interface
-
Standard USB & RS232C interface.
-
Optional GPIB & LAN available
-
-
CE Marked (400V input model ONLY)
-
Safe, reliable, and consistent operation
-
Key Features Lx Series
-
Backward Compatible
-
Compatible with HP6834B & iL Series AC Sources Function & bus compatible with the Agilent HP6834B & California Instruments iL Series
-
-
Three phase and Single phase modes
-
Ideally suited for avionics and defense applications
-
-
3 KVA to 18 KVA Power Levels
-
Match power source and cost to application requirements
-
-
Arbitrary Waveform Generator
-
Test products for harmonics susceptibility
-
-
Built-in Power Analyzer
-
Performs voltage and load current harmonic analysis and waveform acquisition
-
-
Standard IEEE-488, USB & RS232
-
Remote control interface for ATE system integration include
-
The Ls/Lx Series is a completely improved new product based on the popular California Instruments L Series. Both the Ls and Lx feature many basic AC Source capabilities at a very reasonable price.
Ls Series
The Ls Series is an improved version of the classic California Instruments L Series AC power sources. It provides many basic AC source capabilities at an economical cost. Additional capabilities such as arbitrary waveform generation and harmonic measurements can be added as options. The Ls Series can be ordered in either single phase (-1) or three phase (-3) configurations. Power levels range from 3 kVA to 6 kVA in a single chassis. Multiple chassis can be combined for power levels up to 18 kVA. The Ls Series is completely microprocessor controlled and can be operated from a simple front panel keypad. A pair of analog controls located next to the backlit alphanumeric LCD display allows output voltage and frequency to be slewed up or down dynamically. For more advanced operations, a series of menus is provided using a dual line high contrast LCD display. The Lx Series represents a modern AC power source that addresses increasing demands on test equipment to perform more functions at a lower cost. By combining a flexible AC power source with a high-end harmonic power analyzer, the Lx Series systems are capable of handling applications that would traditionally have required multiple instruments.
Lx Series
The Lx Series is completely microprocessor controlled and can be operated from a simple front panel keypad. A pair of analog controls located next to the backlit alphanumeric LCD display allows output voltage and frequency to be slewed up or down dynamically. With precise output regulation and accuracy, high load drive current, multi or single phase mode and built-in power analyzer measurement capabilities, Lx Series AC source/analyzers address many application areas for AC power testing. Additional features, like line arbitrary waveform generation and available DO 160 or MIL 704 test standards, make the Lx Series a good choice for avionics or defense applications. All Lx Series AC sources are equipped with IEEE-488 (GPIB) and RS232C remote control interfaces and support SCPI command language programming.
Features Details Ls Series
L Series Backward Compatibility
The Ls Series offers functional and bus compatibility with the CI L Series AC power sources. Using the APE (Abbreviated Plain English) command syntax, the Ls Series can be used in existing test systems without the need to modify program code. The APE language is part of the -GPIB option, which also adds the GPIB/ IEEE-488 interface.
Applications
With precise output regulation and accuracy, high load drive current, multi or single phase mode and built-in measurement capabilities, Ls Series AC sources address many application areas for AC power testing. Additional features, like available DO 160 or MIL 704 test standards, make the Ls Series a good choice for avionics or defense applications. All Ls Series AC sources are standard equipped with RS232C and USB remote control interfaces. An optional GPIB and LAN interface is also available.
Transient Programming
To simulate common line disturbance occurrences, the Ls Series offers a list of transient steps. These steps can be programmed from the front panel or downloaded over the interface using the GUI program supplied. The GUI allows libraries of commonly used line disturbances to be created on disk for quick recall. Once downloaded, the transient program can be executed from the PC or from the front panel. AC transient generation allows the effect of rapid changes in voltage, frequency, phase angle and waveform shape on the unit under test to be analyzed.
Measurements
The following standard measurements are available from the front panel or via the bus:
- Frequency
- Phase
- Voltage (rms)
- Current(rms)
- Peak Current
- Crest Factor
- Real Power
- Apparent Power
- Power Factor
Diagnostics Capability
The AC Source can perform a self test and report any errors. The self test will run until the first error is encountered and terminate. The response to the self test query command will either be the first error encountered or 0 if no error was found. (Self test passed).
Configuration Options
The Ls Series is available in either three or one phase output configurations and offers voltage ranges of 135 Vrms and 270 Vrms. A wide range of options can be added to customize the Ls Series to meet your specific application requirements.
Voltage Range Options (-HV and -EHV)
Output voltage range options are available to provide higher voltage outputs. In addition to the standard 135/270 V range pair, 156/312 Vrms (-HV option) and 200/400 Vrms (-EHV option) can be specified at the time of order. All voltage ranges are Line to Neutral. On three phase Ls Series models, maximum Line to Line voltages are 467 V (standard), 540 V (-HV option) and 692 V (-EHV option).
Phase Mode (-MODE)
The -MODE option provides automatic switching between three phase and single phase output modes. In single phase mode, all output current is routed to the Phase A output terminal. The -MODE option is available for 3 phase Ls models (e.g. 4500Ls-3).
Waveform Generation (-ADV option)
The standard Ls Series provides sine wave output capability. For more demanding test applications, the advanced option package adds the following waveform capabilities:
- Squarewave.
- Clipped Sinewave - Simulates THD levels to test for harmonic distortion susceptibility.
- Harmonic and Arbitrary (User defined) waveforms.
Using the provided Windows Graphical User Interface (GUI) program, defining harmonic waveforms is as easy as specifying the relative amplitude and phase angle for each of up to 50 harmonics. The waveform data points are generated and downloaded by the GUI to the AC source through the standard RS232C or optional GPIB bus and are retained in non-volatile memory. Up to 50 waveforms can be stored and given a user defined name for easy recall.
Advanced Measurement Functions (-ADV option)
Power analysis of EUT load characteristics is available by adding the -ADV option. Harmonics up to the 50th harmonic (for fundamental frequencies up to 250 Hz) and total harmonic distortion of both voltage and current is provided as well. Harmonic analysis data can be displayed on the front panel display or on the PC using the GUI program. The GUI can also be used to save and print harmonics data in tabular, bar graph or time domain formats. The acquired voltage and current time-domain waveforms for each output phase can be displayed using the GUI program. Waveform displays on the PC. Available display modes include voltage and current combined, three phase voltage, three phase current and true power. The time-domain data is also available for transfer to a PC through the bus when using custom software.
Windows Graphical User Interface
Our Windows compatible Instrument Control Software offers a soft front panel interface for operation from a PC. The following functions are available through this GUI program:
- Steady state output control (all parameters).
- Create, run, save and print transient programs.
- Measure and log standard measurements.
With -ADV option:
- Generate and save harmonic waveforms.
- Generate and save arbitrary waveforms.
- Capture and display Voltage and Current waveforms.
- Measure, display, print and log harmonic voltage and current measurements.
Features Details Lx Series
HP6834B Compatibility
The Lx Series offers functional and bus compatibility with the Agilent HP6834B AC power sources as well as the CI iL Series AC power sources and may be used in existing test systems without the need to modify program code. Power levels of 3000 VA and 4500 VA match the available HP6814B and HP6834B models exactly. Unlike these HP/Agilent models however, the Lx series supports a constant power mode, which provides higher output RMS current at reduced voltage for greater power output at less than full-scale voltage. (except 6000Lx, 12000Lx and 18000Lx) Furthermore, the Lx series can easily be paralleled for higher output power and multi-chassis Lx Systems up to 17.3 KVA are available allowing expansion of existing HP/Agilent based test systems.
The front panel operation has been simplified with a greatly reduced number of buttons while still allowing most functions to be accessed.
Waveform Generation
The Lx Series provides sine and clipped sine waveforms in addition to user defined arbitrary waveforms. Harmonic waveforms can be used to test for harmonics susceptibility of a unit under test. With the help of the supplied Windows Graphical User Interface program, defining harmonic waveforms is as easy as specifying the relative amplitude and phase angle for each of up to 50 harmonics. The user also has the ability to define arbitrary waveform data. Complex AC voltage anomalies can be simulated this way.
The waveform data points generated are downloaded by the GUI to the AC source through either IEEE-488 or RS232C bus and remain in non-volatile memory. Up to 32 user-defined waveforms can be stored and given a descriptive name for easy recall.
Downloaded waveforms are retained in non-volatile memory for recall over the bus or from the front panel.
Transient Generation
To simulate common line disturbance occurrences, the Lx Series offers a list of transient steps. These steps can be programmed from the front panel or downloaded over the interface using the GUI program supplied. The GUI allows libraries of commonly used line disturbances to be created on disk for quick recall. Once downloaded, the transient program can be executed from the PC or from the front panel. AC transient generation allows the effect of rapid changes in voltage, frequency, phase angle and waveform shape on the unit under test to be analyzed. The combination of transients and user defined arbitrary waveforms creates a powerful test platform for AC powered products.
Measurements
The Lx Series measurement system is based on real-time digitization of the voltage and current waveforms using a 4K-sample buffer. The digitized waveform data is processed by a Digital Signal Processor to extract conventional load values such as rms voltage, rms current, real and apparent power. The same data is also used to perform Fast Fourier Transformation (FFT) to extract the harmonic amplitude and phase angle of 50 harmonics.
Standard Measurements
The following standard measurements are available from the front panel or via the bus:
- Frequency
- Phase
- Voltage (rms)
- Current(rms)
- Peak Current
- Crest Factor
- Neutral Current (rms)
- Real Power
- Apparent Power
- Power Factor
Advanced Measurement
Functions In addition to standard load parameters, the Lx Series is capable of measuring voltage and current amplitude and phase harmonics. Total harmonic distortion of both voltage and current is also available. Advanced measurement results like harmonic content of voltage and current for all three phases are available over the bus. The GUI can be used to save and print harmonics data in tabular, bar graph or time domain formats.
The acquired voltage and current time-domain waveforms for each output phase can also be displayed using the GUI program. Waveform displays on the PC include voltage and current combined, three-phase voltage, three-phase current and true power. The time-domain data is also available for transfer to a PC through the IEEE-488 or RS232C bus when using custom software.
Diagnostic Capability
The AC Source can perform a self test and report any errors. The self test will run until the first error is encountered and terminate. The response to the self test query command will either be the first error encountered or 0 if no error was found. (Self test passed).
Windows Graphical User Interface
A Windows 2000/XP™ compatible Graphical User Interface (GUI) offers a soft front panel interface for operation from a PC. The following functions are available through this GUI program:
- Steady state output control (all parameters).
- Create, run, save and print transient programs.
- Generate and save harmonic waveforms.
- Generate and save arbitrary waveforms.
- Measure and log standard measurements.
- Capture and display Voltage and Current waveforms.
- Measure, display, print and log harmonic voltage and current measurements.
California Instruments Ls-Lx Series : Specifications
Output Ls | |
Maximum Power per phase |
3000Ls: 1 phase 3000 VA, 3 phase 1000 VA; 4500Ls: 1 phase 4500 VA, 3 phase 1500 VA; 6000Ls: 1 phase 6000 VA, 3 phase: 2000 VA |
Power factor | 0 to unity at full output VA |
Voltage Ranges | |||
Range | VLow | VHigh | |
AC | 0 - 135 V | 0 - 270 V |
VA Programming Resolution | 100 mV |
Load Regulation | < 0.1 % FS |
Line Regulation | < 0.02 % for 10 % line change |
See -HV and EHV options for alternative voltage range pairs. | |
Programming Accuracy (25°C ±5°C) |
Voltage (rms): ± (0.05% + 0.25) V from 5.0 V to FS; Frequency: ± 0.025%, 3 ø: <1° [45-100 Hz], <1° + 1°/kHz [>1kHz] |
Frequency Range |
45 Hz - 1000 Hz (see -HF option for higher output frequencies) Programmable down to 17 Hz with lower V limit. |
Frequency Resolution |
0.01 Hz at < 81.9 Hz, 0.1 Hz at >82.0 to 819.1 Hz, 1 Hz at > 819 Hz |
Max RMS Current at Low V range | |
At Full Power |
Model | 1 ø | 3 ø |
3000Ls | 44.4 A | 14.8 A |
4500Ls | 44.4 A | 14.8 A |
6000Ls | 44.4 A | 14.8 A |
At Full Scale Voltage |
Model | 1 ø | 3 ø |
3000Ls | 22.2 A | 7.4 A |
4500Ls | 33.3 A | 11.1 A |
6000Ls | 44.4 A | 14.8 A |
Note: Constant power mode on 3000Ls and 4500Ls provides increased current at reduced voltage; |
Current Limit | Programmable from 0 Amps to maximum current for selected range |
Peak Current | 3000Ls: 6 X (lrms @ full scale voltage); 4500Ls: 4 X (lrms @ full scale voltage); 6000Ls: 3 X (lrms @ full scale voltage) |
Output Noise |
100mV rms typ. (20 kHz to 1 MHz) - Standard 250mV rms typ. (20 kHz to 1 MHz) - Option -HF |
Harmonic Distortion | < 1% (at full scale voltage, full resistive load) |
Output Relay | Push button controlled and bus controlled output relay |
Output Lx | |
Maximum Power per phase |
3000Lx: 1 phase: 3000 VA, 3 phase: 1000 VA; |
Power factor | 0 to unity at full output VA |
Voltage Ranges | |||
Range | VLow | VHigh | |
AC | 0 - 150 V | 0 - 300 V |
VA Programming Resolution | 100 mV |
Load Regulation | < 0.1 % FS ALC On or Reg. |
Line Regulation | < 0.02 % for 10 % line change |
See -HV and EHV options for alternative voltage range pairs. | |
Programming Accuracy (25°C ±5°C) |
Voltage (rms): ± (0.05% + 0.25) V from 5.0 V to FS, ALC On or Reg; Frequency: ± 0.025 %; Phase: ± 1° 45-100 Hz, ± (1° + 1°/kHz) 100 Hz-1kHz |
Frequency Range | 45 Hz - 1000 Hz (see -HF option for higher output frequencies) (Derated voltage from 17 Hz - 45Hz) |
Frequency Resolution |
0.01 Hz at < 81.9 Hz, |
Max RMS Current at Low V range |
Phases V Range | VLow | VHigh |
All 3 ø | 12.8 A | 6.4 A |
models 1 ø | 38.4 A | 19.2 A |
At Full Scale Voltage |
Model | VLow | VHigh |
3000Lx 3 ø | 6.6 A | 3.3 A |
3000Lx 1 ø | 20.0 A | 10.0 A |
4500Lx 3 ø | 10.0 A | 5.0 A |
4500Lx 1 ø | 30.0 A | 15.0 A |
6000Lx 3 ø | 12.8 A | 6.4 A |
6000Lx 1 ø | 38.4 A | 19.2 A |
Note: Constant power mode on 3000Lx and 4500Lx provides increased current at reduced voltage; 6000Lx provides maximum power output. |
Current Limit | Programmable from 0 Amps to maximum current for selected range |
Peak Current | 3000Lx: 5.7 X (lrms @ full scale voltage); 4500Lx: 3.8 X (lrms @ full scale voltage); 6000Lx: 3 X (lrms @ full scale voltage) |
Output Noise |
100mV rms typ. 250mV rms typ. for -HF option |
Harmonic Distortion | < 1% (at full scale voltage, full resistive load) |
Output Relay | Push button controlled and bus controlled output relay |
Input Ls | |
Voltage |
Models 3000Ls, 4500Ls, 9000Ls, 13500Ls: Standard: 208-230 ± 10% VAC, (L-L, 3 Phase); Option -400: 400 ± 10% VAC (L-L, 3 Phase) Includes CE Mark; Models 6000Ls, 12000Ls, 18000Ls: Standard 208-230 + 10% VAC (L-L, 3 Phase) Notes: 1. Input must be specified when ordering. 2. -400 option not availble on 6000Ls, 12000Ls, 18000Ls. 3. 3000Ls can be operated from 1 phase AC. 4. -480V option ± 5% VAC (L-L, 3 Phase) available on 3000Ls & 4500 Ls (3 phase output only) |
Line Current (rms per phase) |
Model | 187 VLL | 187 VLN (1 ø) | 208 VLL | 360 VLL |
3000Ls | 19 A | 32 A | n/a | 10 A |
4500Ls | 31 A | n/a | n/a | 16 A |
6000Ls | n/a | n/a | 38 A | n/a |
Inrush Current (Per phase) |
@ 180-254 V: 50 A peak @ 360-440 V: 83 A peak |
Line Frequency | 47-440 Hz |
Efficiency | 80% typical |
Power Factor | 0.7 typical |
Hold-up Time | At least 10 ms |
Input Lx | |
Voltage |
ModeLx 3000Lx, 4500Lx, 9000Lx, 13500Lx: Standard: 208-230 ± 10% VAC, (L-L, 3 Phase); Option -400: 400 ± 10% VAC (L-L, 3 Phase) Includes CE Mark; ModeLx 6000Lx, 12000Lx, 18000Lx: Standard 208-230 + 10% VAC (L-L, 3 Phase) Notes: 1. Input must be specified when ordering. 2. -400 option not availble on 6000Lx, 12000Lx, 18000Lx. 3. 3000Lx can be operated from 1 phase AC. |
Line Current (rms per phase) |
Model | 3000Lx | 3000Lx (1Phase) | 4500Lx | 6000Lx (@ 280V) |
187 VLL | 19 A | 32 A | 31 A | 38 A |
360 VLL | 10 A | n/a | 16 A | n/a |
Inrush Current (Per phase) |
@ 180-254 V: 50 A peak @ 360-440 V: 83 A peak |
Line Frequency | 47-440 Hz |
Efficiency | 80% typical |
Power Factor | 0.7 typical |
Hold-up Time | At least 10 ms |
Ls Measurements - Standard (AC Measurements) | ||||
Parameter | Frequency | Phase | Voltage (AC rms) | Current (AC rms) |
Range | 45-1000Hz |
45-100Hz 100-1000Hz |
0-400V | 0-50A |
Accuracy* (±) 1 ø mode (-1) |
0.1% + 1 digit |
0.5° 2° |
0.05% + 250 mV | 0.1% + 150 mA |
Accuracy* (±) 3 ø mode (-3) |
0.1% + 1 digit |
0.5° 2° |
0.05% + 250 mV | 0.1% + 50 mA |
Resolution* |
0.01 Hz / 0.1 Hz / 1 Hz |
0.1° | 10 mV | 1 mA |
Parameter | Real Power | Apparent Power | Power Factor |
Range | 0-6kW | 0-6kVA | 0.00-1.00 |
Accuracy* (±) 1 ø mode (-1) | 0.15% + 9 W | 0.15% + 9 VA | 0.03 |
Accuracy* (±) 3 ø mode (-3) | 0.15% + 3 W | 0.15% + 3 VA | 0.01 |
Resolution* | 1 W | 1 VA | 0.01 |
* Accuracy specifications are in % of reading and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are multiplied by 3. Power factor accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 30 Vrms. |
Lx Measurements - Standard (AC Measurements) | ||||
Parameter | Frequency | Phase | Voltage (AC rms) | Current (AC rms) |
Range |
45.00-81.91 Hz 82.0-819.1 Hz > 819 Hz |
0.0° - 359.9° | 0-400V | 0-50A |
Accuracy* (±) 1 ø mode (-1) |
0.1% + 1 digit |
0.5° < 100 Hz 2° > 100 Hz |
0.05% + 0.25V | 0.1% + 0.15A |
Accuracy* (±) 3 ø mode (-3) |
0.1% + 1 digit |
0.5° < 100 Hz 2° > 100 Hz |
0.05% + 0.25V | 0.1% + 0.05A |
Resolution* |
0.01 Hz / 0.1 Hz / 1 Hz |
0.1° / 1° | 10 mV | 1 mA |
Parameter | Crest Factor | Real Power | Apparent Power | Power Factor |
Range | 1.00 - 10.0 | 0-6kW | 0-6kVA | 0.00-1.00 |
Accuracy* (±) 1 ø mode (-1) |
1.5% | 0.15% + 9 W | 0.15% + 9 VA | 0.03 |
Accuracy* (±) 3 ø mode (-3) |
1.5% | 0.15% + 3 W | 0.15% + 3 VA | 0.01 |
Resolution* | 0.01 | 1 W | 1 VA | 0.01 |
* Accuracy specifications are in % of reading + scale error and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are times three. CF accuracy applies for Irms > 50 % of max. PF accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 20 Vrms. |
Ls System | |
Storage | Setup: 16 complete instrument setups / Transient List: 100 transient steps per list (SCPI mode) or 16 transient registers (APE mode) |
Trigger Input/Output | Input: Triggers measurements or transient steps - SMA connector: 10K pull-up / Output: SMA Connector: HCTTL output |
Lx System | |
Storage | Setup: 16 complete instrument setups / Transient List: 100 transient steps per list (SCPI mode) |
Trigger Input/Output | Input: Triggers measurements or transient steps - SMA connector: 10K pull-up / Output: SMA Connector: HCTTL output |
Ls Protection | |
Overload/Temp/Voltage | Overload: Constant current or constant voltage mode; Over temperature: Automatic Shutdown; Over voltage: Automatic shutdown |
Lx Protection | |
Overload/Temp/Voltage | Overload: Constant current or constant voltage mode; Over temperature: Automatic Shutdown; Over voltage: Automatic shutdown |
Regulatory/RFI Suppresion | IEC1010, EN50081-2, EN50082-2, CE (for 400V input only), EMC, and safety mark requirements / RIF Suppression: CISPR 11, Group1, Class A |
Ls Remote Control | |
IEEE-488 Interface | IEEE-488 (GPIB) talker listener. Subset: AH1, DC1, DT1, L3, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
USB Interface & Ethernet (option) | Version: USB 1.1; Speed: 460 Kb/s maximum / Ethernet Interface (Optional): specify -LAN option. 10BaseT, 100BaseT, RJ45 |
RS232C Interface | Bi-directional serial interface; 9-pin D-shell connector. Handshake: CTS, RTS. Databits: 7 w/ parity, 8 w/o parity. Stopbits: 2. Baud rate: 9600 to 115200. Supplied with RS232C cable / Code and Format: SCPI; APE and Able : option -GPIB |
Lx Remote Control | |
IEEE-488 Interface | IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
USB Interface & Ethernet (option) | IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
RS232C Interface | Bi-directional serial interface; 9-pin D-shell connector. Handshake: CTS, RTS. Databits: 7 w/ parity, 8 w/o parity. Stopbits: 2. Baud rate: 9600 to 115200. Supplied with RS232C cable / Code and Format: SCPI / Not enabled if LAN option is present. |
Ls Physical Dimensions | |
Dimensions (per chassis) | Height: 10.5” (267 mm), Width: 19” (483 mm), Depth: 23.7” (602 mm) (depth includes rear panel connectors) |
Weight | Chassis: Net: 193 lbs / 87.7 Kg, Shipping: 280 lbs / 127.3 Kg (for /2 or /3 model configuarations multiply by number of chassis). |
Vibration and Shock | Designed to meet NSTA project 1A transportation levels |
Air Intake/Exhaust | Forced air cooling, side air intake, rear exhaust |
Temperature | Temperature: Operating: 0 to 35° C, full power / Storage: -40 to +85° C; |
Diagnostics | Built-in self test available over bus (*TST) |
Rear Panel Connectors | * Three phase AC input and output terminal block with safety cover. * IEEE-488 (GPIB) connector (Option -GPIB). * 9-pin D-Shell RS232C connector (RS232 DB9 to DB9 cable supplied). * Remote Inhibit (INH) and Discrete Fault Indicator (DFI). * Remote voltage sense terminal block. * Trigger In1 and Trigger Out1. * System interface connectors. * Auxilary Output (Option -AX) |
Lx Physical Dimensions | |
Dimensions (per chassis) | Height: 10.5” (267 mm), Width: 19” (483 mm), Depth: 23.7” (602 mm) (depth includes rear panel connectors) |
Weight | Chassis: Net: 193 lbs / 87.7 Kg, Shipping: 280 lbs / 127.3 Kg (for /2 or /3 model configuarations multiply number of chassis) |
Vibration and Shock | Designed to meet NSTA project 1A transportation leveLx |
Air Intake/Exhaust | Forced air cooling, side air intake, rear exhaust |
Temperature | Temperature: Operating: 0 to 35° C, full power / Storage: -40 to +85° C; |
Diagnostics | Built-in self test available over bus (*TST) |
Rear Panel Connectors |
* Three phase AC input and output terminal block with safety cover. * IEEE-488 (GPIB) connector, USB connector, RJ45 connector (with -LAN Option). * 9-pin D-Shell RS232C connector (RS232 DB9 to DB9 cable supplied). * Remote Inhibit (INH) and Discrete Fault Indicator (DFI). * Remote voltage sense terminal block. * Trigger In1 and Trigger Out1. * System interface connectors. * Auxilary Output (Option -AX) |
Ls Option -ADV Specifications | |||
Measurements | |||
Parameter |
Frequency Fundamental Harmonics |
Voltage | Current |
Range | 45-81.91 Hz / 45.00 Hz-16 kHZ | 0 - 400 V | 0 - 20 Amps |
Accuracy* (±) | 0.1% ± 1 digit / 0.1% + 2 digit | 0.05% + 0.25V / 0.1% + 0.1%/kHZ + 0.25 | 0.1% + 0.05A / 0.1% + 0.1%/kHz +0.05A |
Resolution | 01 Hz / 0.1 Hz. | .01 V / .01V | .01 A / .01 A |
* Accuracy specifications are in a percent of reading for single unit in 3-phase mode. | |
Waveforms | Pre-defined: Sine, Square, Clipped, User-defined, 1024 addressable data points; Storage: 50 user waveforms, non-volatile memory |
Data Acquisition | Parameters: Voltage, Current time domain, per phase; Resolution: 4096 data points, 10.4 usec (1ø) or 31.25 usec (3ø) sampling interval |
Lx Ls -ADV Specifications | |||
Measurements | |||
Parameter |
Frequency Fundamental Harmonics |
Voltage | Current |
Range | 45-1000 Hz / 45 - 16 kHz | Harmonics 2 - 50 | Harmonics 2 - 50 |
Accuracy* (±) | 0.1% + 1 digit / 0.1% + 2 digits | 0.1% + 0.1% /1 kHz +0.25V | 0.1% + 0.1% /1 kHz +0.05A |
Resolution | 0.01 Hz / 0.1 Hz | 10 mV | 10 mA |
* Accuracy specifications are in a percent of reading for single unit in 3-phase mode. | |
Waveforms | Pre defined: Sine, Square, Clipped; User defined: 1024 addressable data points; Storage: 50 user waveforms, non-volatile memory |
Data Acquisition | Parameters: Voltage & Current time domain, per phase; Resolution: 4096 data points, 10.4 usec (1ø) or 31.25 usec (3ø) sampling interval |
Ls Option -AX Specifications | |
Option -AX | Provides seperate isolated 26 VAC regulated and 5 Vac unregulated outputs. The 26 V is normally used for servo-synchro excitation, and the 5 V for lamp power. 26 Volt-Accuracy: ± 2%. Current capacity: 3 ARMS. Frequency: 360/440 Hz. Regulation ± 1.5%. 5 Volt-Accuracy: ± 5%. Current capacity: 1 ARMS |
Lx Option -AX Specifications | |
Option -AX | Provides seperate isolated 26 VAC regulated and 5 Vac unregulated outputs. The 26 V is normally used for servo-synchro excitation, and the 5 V for lamp power. 26 Volt-Accuracy: ± 2%. Current capacity: 3 ARMS. Frequency: 360/440 Hz. Regulation ± 0.05%. 5 Volt-Accuracy: ± 5%. Current capacity: 5 ARMS |
Ls Standard -EHV Specifications | |
Voltage / Frequency Ranges | Voltage: Low: 0-200 Volt; High: 0-400 Volt / Frequency: With -HF option: 45 Hz - 5000 Hz |
Max RMS Current at Full Power | 3 Phase: High: 5.0 A, Low 10.0 A; 1 Phase: High: 15.0A, Low: 30.0 A; Note: Constant power modes on 3000Ls and 4500Ls. Current available at reduced voltage for 3000Ls, 4500Ls, and max voltage for 6000Ls |
Max RMS Current at FSVoltage | 3000Ls: 3 Phase: High: 2.5 A, Low: 5.0 A; 1 Phase: High 7.5 A, Low: 15.0 A; 4500Ls: 3 Phase: High: 3.8, Low 7.5; 1 Phase: High: 11.3 A, Low: 22.5 A; 6000Ls: 3 Phase: High: 5.0 A, Low 10.0 A; 1 Phase: High: 15.0 A, Low: 30.0 A |
Lx Standard -EHV Specifications | |
Voltage / Frequency Ranges | Low Range: 0-135 Volt; High Range: 0-270 Volt RMS: With -HF option: 45 Hz - 5000 Hz |
Max RMS Current at Full Power | 3 Phase: High: 7.4 A, Low 14.8 A; 1 Phase: High: 22.2 A, Low: 44.4 A; Note: Constant power modes on 3000Lx and 4500Lx. Current available at reduced voltage for 3000Lx, 4500Lx, and max voltage for 6000Lx |
Max RMS Current at FSVoltage | 3000Lx: 3 Phase: High: 3.7 A, Low: 7.4 A; 1 Phase: High 11.1 A, Low: 22.2 A; 4500Lx: 3 Phase: High: 5.6, Low 11.1; 1 Phase: High: 16.7 A, Low: 33.3 A; 6000Lx: 3 Phase: High: 7.4 A, Low 14.8 A; 1 Phase: High: 22.2 A, Low: 44.4 A |
Ls Option -HV Specifications | ||||
Measurements: F < 2000 Hz: See standard Ls Specifications; F > 2000 Hz: See table > | ||||
Parameter | Frequency | Phase | Voltage (AC rms) | Current (AC rms) |
Range |
<2000 Hz >2000 Hz |
0-400 V< 1000 Hz / > 1000 Hz | 0-50 A | |
Accuracy* (±) 1 ø mode (-1) |
0.1% ± 1 digit |
0.5° 2° 5° |
0.05% + 250 mV | 0.5% + 150 mA |
Accuracy* (±) 3 ø mode (-3) |
0.1% ± 1 digit |
0.5° 2° 5° |
0.1 % + 0.1%/kHz + 300MV | 0.5% + 50 mA |
Resolution* |
0.01 Hz / 0.1 Hz / 1 Hz |
0.1° | 10 mV | 1 mA |
Parameter | Real Power | Apparent Power | Power Factor |
Range | 0-6 kW | 0-6 kVA | 0.00-1.00 |
Accuracy* (±) 1 ø mode (-1) |
0.5% + 9W | 0.5% + 9 VA | 0.03 |
Accuracy* (±) 3 ø mode (-3) |
0.5% + 3W | 0.5% + 3 VA | 0.01 |
Resolution* | 1 W | 1 VA | 0.01 |
* Accuracy specifications are in % of reading and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are multiplied by 3. Power factor accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 30 Vrms. |
Frequency Range | 45 Hz- 5000 Hz |
Output Noise | <250 mVrms typical (20 kHz to 1 MHz) |
Lx Option -HV Specifications | ||||
Parameter | Frequency | Phase | Voltage (AC rms) | Current (AC rms) |
Range | 45.00 - 5000 Hz | 0.0°-359.9° |
0-400 V < 1000 Hz / > 1000 Hz |
0-50 A |
Accuracy* (±) 1 ø mode (-1) |
0.1% + 1 digit |
0.5° < 100Hz 2° < 2Khz 5° > 2Khz |
0.05% + 0.25V / 0.1 % + 0.1%/kHz + 0.3V |
0.5% + 0.15A |
Accuracy* (±) 3 ø mode (-3) |
0.1% + 1 digit |
0.5° < 100Hz 2° < 2Khz 5° > 2Khz |
0.05% + 0.25V / 0.1 % + 0.1%/kHz + 0.3V |
0.5% + 0.05A |
Resolution* | 0.01 Hz / 0.1 Hz / 1 Hz | 0.1° | 10 mV | 1 mA |
Parameter | Crest Factor | Real Power | Apparent Power | Power Factor |
Range | 1.00 - 10.0 | 0-6 kW | 0-6kVA | 0.00-1.00 |
Accuracy* (±) 1 ø mode (-1) |
1.5% | 0.5% + 9 W | 0.5% + 9 VA | 0.03 |
Accuracy* (±) 3 ø mode (-3) |
1.5% | 0.5% + 3 W | 0.5% + 3 VA | 0.01 |
Resolution* | 0.01 | 1 W | 1 VA | 0.01 |
* Accuracy specifications are in % of reading and apply above 100 counts. For multi-chassis configurations, current, power range and accuracy specifications are times three. CF accuracy applies for Irms > 50 % of max. Power factor accuracy applies for PF > 0.5 and VA > 50% of max. Frequency measurement specification valid for output > 20 Vrms. |
Frequency Range | 45 Hz- 5000 Hz (Derated voltage from 17 Hz - 45Hz) |
Frequency Accuracy | ±0.025% |
Output Noise | 250 mVrms typical (20 kHz to 1 MHz) |