Dualos - LCF Open Line Plugs
All plugs ship with Skydrol (BMS3-11) Compatible O-Rings, Viton® Cuff and Four Metal Clamps. Parts in compliance with all SMOT document requirements.
|
Part Number |
Tube OD |
Tube ID |
Wall Thickness |
Tail Stamp |
|
NEO 406F-A-06 |
0.375 |
0.311 |
0.032 |
N6 |
|
NEO 407F-A-06 |
0.375 |
0.337 |
0.019 |
W6 |
| NEO 410F-A-08 |
0.500 |
0.414 |
0.043 |
N8 |
|
NEO 411F-A-08 |
0.500 |
0.456 |
0.022 |
W8 |
| NEO 412F-A-10 |
0.625 |
0.517 |
0.054 |
N10 |
|
NEO 413F-A-10 |
0.625 |
0.579 |
0.023 |
W10 |
|
NEO 416F-A-12 |
0.750 |
0.620 |
0.065 |
N12 |
|
NEO 417F-A-12 |
0.750 |
0.696 |
0.027 |
W12 |
|
NEO 420F-A-04E |
0.457 |
0.251 |
– |
NE-04 |
|
NEO 421F-A-08E |
0.772 |
0.503 |
– |
NE-08 |
|
NEO 422F-A-10E |
0.929 |
0.629 |
– |
NE-10 |
|
NEO 423F-A-12E |
1.110 |
0.755 |
– |
NE-12 |
*Approximate Dimensions [inches]
More Product Information
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Shielded, coaxial opens are used in the calibration of vector network analyzers to provide a nominal 180° phase offset from a compatible reference short over a wide range of frequencies. At these frequencies, open circuit terminations are inherently imperfect. Shielding the open essentially eliminates radiation loss, but creates a residual frequency-sensitive capacitance. An accurate knowledge of the open’s effective capacitance is essential to an accurate calibration of the analyzer. Maury opens are characterized for effective capacitance versus frequency by means of a fourth order polynomial curve fit, and the nominal capacitance coefficients are provided with each unit.
- Directly compatible with most commercial VNA’s
- Available as polynomial and characterized device kits
- Measure S-Parameters with uncertainty when used in conjunction with Maury’s Insight software platform
Maury offers coaxial and waveguide VNA calibration kits.
Coaxial calibration kits are offered in Polynomial SOLT, Characterized Device (CD) SOLT, and TRL, depending on the connector series. Where available, CD kits improve calibration accuracy when compared to SOLT kits based on polynomial definitions as each calibration kit is provided with individually characterized short, open and fixed load standards, whose S-parameters can be loaded into commercial VNAs directly or when used with Maury’s Insight™ software platform. When combined with Insight™, users will be able to quantify the uncertainty contribution of their calibration kit to their overall measurements. CD cal kits result in TRL-like accuracy with fixed-load SOLT ease-of-use.
Superior Mechanics
- Highly stable granite base
- Independent, coarse movement of X and Y axes, combined with easy fine adjustments down to submicron ranges
- 1 µm repeatable separation stroke
- Excellent measurement accuracy and repeatability
- Fast navigation and high-precision probe positioning
See "Specifications & Details" tab for more key features
Dualos
787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines. 3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors