Advanced Illumination - DCS-MP Manual Dimming Accessory
- Detented, 30 position potentiometer for repeatable dimming with cable inline controllers
- Built in DIN-rail or panel mounting feature
- Flip up cover for potentiometer to prevent accidental adjustments
- Spring clamp wiring terminal for vibration proof installation
- NEW M12 selector switch for use with iCS 2 (IC) and iCS 3 (I3) M12-based lights
General Specs
|
Length |
89.7mm (3.53in) |
|---|---|
|
Width |
35.6mm (1.40in) |
|
Height |
60.7mm (2.39in) |
|
Weight |
185g |
|
Operating Temperature |
-25°C to 57°C |
|
Compliance |
CE, RoHS |
*Values shown are based on controller component limitations. Actual limitations will vary depending on the limits set for the connected light head. These limits are determined using Advanced Illumination's proprietary SignaTechTM (Signature Technology) in order to ensure safe peak performance.
** Various light head configurations available, including 1 x 4-channel quadrant (Q1) control or multiple single light heads (Q4) per block.
Mechanical Specs
Electrical Specs
Part Number Key

More Product Information
- Latest Global and Rolling Shutters sensors from Sony® - from 2 to 12 MP
- USB3 Vision interface
- Compact fully-enclosed design with features needed by modern vision systems
- Provide advanced vision performance while using less power, less space, and fitting increasingly tight industry budgets
- With an intensity of over 150 klx at 300 mm WD in continuous operation, the SL316 UltraSeal Spot Light delivers industry-leading intensity with consistent uniformity.
- Available with narrow, medium, and wide lensing options as well as a non-lensed configuration for high dispersion.
- Configurable in eleven wavelength options.
- Compatible with all Ai inline and discreet control systems. The SL316 can be operated in continuous, gated continuous, pulsed, and adaptive pulsed modes with dimming options for brightness control.
The laboratory and research industry faces unique challenges including long-standing, legacy pain points and frequently evolving needs. These include paramount safety and regulatory requirements for lab workers and patients alike, the need for high containment and sterility, and the integration of cutting-edge technologies. Complex and sensitive facilities require specialized testing solutions to ensure compliance, safety, and reliability. Effective planning and laboratory design and construction are crucial to creating environments that support advanced research and manufacturing processes, especially in the pharmaceutical and medical device sectors.
- The RL4260 is characterized as a Medium Aimed Bright Field ring light.
- Precisely aimed LEDs provide a level of lighting control not found in traditional illuminators.
- A range of standoffs and fields of view may be specified at the time of order.
- The ring light is available in a wide range of wavelengths from UV to IR, including a 3 channel RGB version.
- Diffuser and polarizer options are also available.
- The large inner diameter of the ring light can accommodate lenses up to 55mm in diameter.
- The light can also be ordered with an optional mounting ring.
- Boost performance by up to 3x over its precursor thanks to an Intel x6000 series embedded processor
- Capture high-resolution images at high speed through a choice of CMOS sensors from two to 16 Megapixels
- Deploy in dirty, humid, or harsh industrial environments by way of a compact IP67-rated design
- Communicate actions and results to other automation and enterprise equipment via real-time digital I/Os, and Ethernet (TCP/IP, CC-Link IE Field Basic, EtherNet/IP™2, Modbus® , PROFINET® , and native robot interfaces)
- Handle Human-Machine Interface (HMI) function by way of VGA and USB connectivity
- Simplify vision setup and upkeep via integrated lens focusing and illumination intensity control
- Synchronize to the manufacturing line through the support for incremental rotary encoders
- Solve machine vision applications efficiently with Aurora Design Assistant by constructing flowcharts instead of writing program code
- Maintain control and independence through the ability to code custom flowchart steps
- Tackle machine vision applications with utmost confidence using field-proven tools for analyzing, locating, classifying, measuring, reading, and verifying
- Leverage deep learning for visual inspection through image classification and segmentation tools
- Revolutionary technology advancement for wafer and die-level photonics probing
- Real-time in-situ calibrations
- Singulated die testing
- True die-level edge coupling
- In-situ power measurements
- Advanced calibration technologies
- Enables autonomous measurements
See "Specifications & Details" tab for more key features
- Detented, 30 position potentiometer for repeatable dimming with cable inline controllers
- Built in DIN-rail or panel mounting feature
- Flip up cover for potentiometer to prevent accidental adjustments
- Spring clamp wiring terminal for vibration proof installation
- NEW M12 selector switch for use with iCS 2 (IC) and iCS 3 (I3) M12-based lights
- The RL2115 is characterized as a Compact Aimed Dark Field ring light.
- Precisely aimed LEDs provide a specific and repeatable light pattern on the imaging plane.
- There are a wide range of wavelengths available from UV to IR.
- 100 MHz, 200 MHz, 350 MHz, 500 MHz and 1 GHz bandwidths
- Up to 4 GS/s sample rate
- Long Memory – up to 20 Mpts
- 10.1” capacitive touch screen display
- 16 Digital Channel MSO option
- MAUI - Most Advanced User Interface
- Designed for Touch
- Built for Simplicity
- Made to Solve
- Advanced Anomaly Detection
- Fast Waveform Update
- History Mode - Waveform Playback
- WaveScan - Search and Find
- Multi-Instrument Capabilities
- Protocol Analysis - Serial Trigger and Decode
- Waveform Generation - Built-in Function Generator
- Digital Voltmeter and Frequency Counter
- Future Proof
- Upgradeable Bandwidth
- Field Upgradable Software and Hardware Options
Advanced Illumination
Machine Vision Lighting Solutions