Brandywine - FDU-160i Intelligent Frequency Distribution Amplifier
- Network Enabled Frequency Distribution Amplifier
- Dual Frequency Inputs with Auto Failover
- Low Phase Noise Reference Frequency Outputs
- Programmable per channel amplitude
- 1U 19” rack mount
- Redundant Hot Swappable Power Supplies
The FDU-160i is a high performance signal distribution amplifier designed for use with Brandywine high precision time and frequency sources contained in a compact 1U rack-mount chassis.
The FDU accepts two sets of inputs, comprising the reference frequency (typically 10MHz) and status from the source. The FDU provides automatic changeover should one of the on-line source inputs fail. Manual source select override is available on the front panel, or through the Ethernet interface.
A variety of status indicators are located on the front panel for instant visual feedback, together with manual controls for source selection. A 10/100 base T Ethernet interface provides full control over the functionality of the system, including reference selection and output amplitude (on a per channel basis). User control of the unit is via a built-in Web Browser with user-friendly graphical interface, or via SNMP v2c for system applications.
Applications for the FDU-160i include secure communications systems, satellite ground stations, digital television broadcasting and any system requiring highly reliable frequency outputs.
Variations
Model Number |
Description |
Oscillator Type |
Power Supply |
Form Factor |
Power Type |
Output Format |
Number of Outputs |
Input Format |
Number of Inputs |
FDU-160i-10MHz |
Intelligent Frequency Distribution Amplifier - 10MHz version |
None |
Dual AC |
1U |
AC |
10 MHz |
16 |
10 MHz |
2 |
FDU-160i-5 MHz |
Intelligent Frequency Distribution Amplifier - 5MHz version |
None |
Dual AC |
1U |
AC |
5 MHz |
16 |
5 MHz |
2 |
FDU-160i-5 MHz/15dBm |
Intelligent Frequency Distribution Amplifier - 5MHz/15dBm version |
None |
Dual AC |
1U |
AC |
5MHz at 15 dBm levels |
16 |
5MHz at 15 dBm levels |
2 |
Specifications
Frequency |
10 MHz, +/- 5PPM |
---|---|
Amplitude and Impedance |
0.5-1Vrms 50 Ω |
Isolation |
Transformer Coupled |
Number of Inputs |
2 |
Connector Type |
BNC |
Input Selection |
Manual, Auto |
Number of Inputs |
2 |
---|---|
Signal Type |
TTL |
Active Level |
Selectable for active high or low |
Action |
Forces on-line changeover |
Number of Outputs |
16 |
---|---|
Frequency |
Same as input, 10 MHz |
Optional |
1-20, 1, 5 MHz |
Output Level |
5dBm to +13dBm, short-circuit proof |
Connector Type |
BNC |
Harmonic Distortion |
-40 dBc |
Cross Talk |
-80 dBc |
Spurious |
-80 dBc |
Additive Phase Noise@10MHz |
row1 |
1 HZ |
-132 dBc |
10 Hz |
-142 dBc |
100 Hz |
-155 dBc |
1 kHz |
-163 dBc |
10 kHz |
-163 dBc |
Network Interface
Interface Type |
10/100 BaseT |
---|---|
Protocols |
HTTP, DHCP, SNMP V2c, IPV4 |
Connector Type |
RJ45 |
Display Type |
16 Bicolor LED |
---|---|
Functions |
Output status, Ethernet settings |
Type |
Dry relay form C contacts, Ethernet SNMP trap |
---|---|
Alarm Function |
Summary of all input/output alarms (relay), Individual input, output, power (Ethernet) |
Redundancy |
Dual Redundant, Single supply maintains complete unit |
---|---|
Voltage |
90-240 VAC 50/60Hz, 18-36V DC Optional, 36-72VDC Optional |
Power Consumption |
<15W |
Environmental
Temperature |
|
---|---|
Operating |
-10 to +55ºC non condensing |
Storage |
-40 to +85ºC |
Product Safety |
EN60950-1: 2006 + A11-2009 +A1:2010 A12:2011 |
EMC Emission |
EN55022 Class A, EN50082-2, FCC Chapter 15 Class A |