Brandywine - FDU-160i Intelligent Frequency Distribution Amplifier

  • Network Enabled Frequency Distribution Amplifier 
  • Dual Frequency Inputs with Auto Failover 
  • Low Phase Noise Reference Frequency Outputs 
  • Programmable per channel amplitude 
  • 1U 19” rack mount 
  • Redundant Hot Swappable Power Supplies

Variations

Model Number

Description

Oscillator Type

Power Supply

Form Factor

Power Type

Output Format

Number of Outputs

Input Format

Number of Inputs

FDU-160i-10MHz

Intelligent Frequency Distribution Amplifier - 10MHz version

None

Dual AC

1U

AC

10 MHz

16

10 MHz

2

FDU-160i-5 MHz

Intelligent Frequency Distribution Amplifier - 5MHz version

None

Dual AC

1U

AC

5 MHz

16

5 MHz

2

FDU-160i-5 MHz/15dBm

Intelligent Frequency Distribution Amplifier - 5MHz/15dBm version

None

Dual AC

1U

AC

5MHz at 15 dBm levels

16

5MHz at 15 dBm levels

2


Specifications

Frequency

10 MHz, +/- 5PPM 

Amplitude and Impedance

0.5-1Vrms 50 Ω 

Isolation

Transformer Coupled 

Number of Inputs

2

Connector Type

BNC

Input Selection

Manual, Auto 


Number of Inputs

2

Signal Type

TTL

Active Level

Selectable for active high or low 

Action

Forces on-line changeover 


Number of Outputs

16

Frequency

Same as input, 10 MHz 

Optional

1-20, 1, 5 MHz 

Output Level

5dBm to +13dBm, short-circuit proof 

Connector Type

BNC

Harmonic Distortion

-40 dBc 

Cross Talk

-80 dBc 

Spurious

-80 dBc 

Additive Phase Noise@10MHz

row1

1 HZ

-132 dBc 

10 Hz

-142 dBc 

100 Hz

-155 dBc 

1 kHz

-163 dBc 

10 kHz

-163 dBc 


Network Interface

Interface Type

10/100 BaseT 

Protocols

HTTP, DHCP, SNMP V2c, IPV4 

Connector Type

RJ45


Display Type

16 Bicolor LED 

Functions

Output status, Ethernet settings 


Type

Dry relay form C contacts, Ethernet SNMP trap 

Alarm Function

Summary of all input/output alarms (relay), Individual input, output, power (Ethernet) 


Redundancy

Dual Redundant, Single supply maintains complete unit 

Voltage

90-240 VAC 50/60Hz, 18-36V DC Optional, 36-72VDC Optional 

Power Consumption

<15W 


Environmental

Temperature

Operating

-10 to +55ºC non condensing 

Storage

-40 to +85ºC 

Product Safety

EN60950-1: 2006 + A11-2009 +A1:2010 A12:2011 

EMC Emission

EN55022 Class A, EN50082-2, FCC Chapter 15 Class A 