Teledyne LeCroy - T3SA Series 2.1 GHz and 3.2 GHz Spectrum Analyzers
-
All Digital IF technology
-
10.1” WVGA (1024 x 600) Display
-
Frequency range from 9 KHz up to 3.2 GHz
-
-161 dBm/Hz Displayed Average Noise Level (Typ)
-
-98 dBc/Hz @ 10 khz Offset Phase Noise (Typ)
-
Total Amplitude Accuracy < 0.7 dB
-
1 Hz Minimum Resolution Bandwidth (RBW)
-
Comes with standard Preamplifier and Tracking Generator Kits.
-
Optional Reflection/VSWR, Advanced Measurement Kit and EMI Pre-compliance measurement kits.
Teledyne Test Tools new T3SA3000 family of Spectrum Analyzers offers a frequency range of 9 KHz to either 2.1/3.2 GHz alongside many impressive features. With their light weight, small form factor, and user friendly interface, these Spectrum Analyzers take powerful and reliable automatic measurements that are presented on a large, bright, easy to read touch screen display. Typical uses for the T3SA3000 series are research and development, education, production, maintenance, and pre-compliance testing.
The T3SA3000 series has four selectable color-coded traces which can be used for different functions such as Max Hold, Min Hold, Clear-Write, Math, Average, etc.
More Product Information
-
DigRF v4 Decodes
-
Low-speed (26 Mb/s)
-
Medium-speed (1248 Mb/s)
-
High-speed (1456 Mb/s)
-
-
DigRF v3 Decodes
-
Low-speed (6.5 Mb/s)
-
Medium-speed (26 Mb/s)
-
High-speed (312 Mb/s)
-
-
Convert DigRF 3G and v4 I and Q digital data to corresponding analog waveforms
-
Correlate analog waveforms with protocol decode on one screen
-
View decoded data in hexadecimal format
-
Decode information expands as the time base is adjusted or zoomed
-
Convenient table display with quick “Zoom to byte” capability
-
Quick search capability for specific message packets
-
Highest resolution – 12 bits all the time
-
More capability – integrates multiple instruments into one
-
Comprehensive probe support – supports over 30 probes in 9 categories
-
MAUI with OneTouch user interface for intuitive and efficient operation
-
Highest resolution - HD4096 Technology, 12 bits all the time
-
Bigger Display, smaller footprint, most bench space
-
More capability, increased productivity
-
1 kV CAT safety rated
-
Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
-
1% gain accuracy
-
High offset capability at both high and low attenuation
-
AC or DC coupling
-
6 meter cable
-
ProBus active probe interface with automatic scaling
-
Auto-zero capabilities
-
Wide oscilloscope compatibility
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
All Digital IF technology
-
10.1” WVGA (1024 x 600) Display
-
Frequency range from 9 KHz up to 3.2 GHz
-
-161 dBm/Hz Displayed Average Noise Level (Typ)
-
-98 dBc/Hz @ 10 khz Offset Phase Noise (Typ)
-
Total Amplitude Accuracy < 0.7 dB
-
1 Hz Minimum Resolution Bandwidth (RBW)
-
Comes with standard Preamplifier and Tracking Generator Kits.
-
Optional Reflection/VSWR, Advanced Measurement Kit and EMI Pre-compliance measurement kits.
-
S-parameters DC to 40 GHz, single-ended and mixed-mode
-
Impedance Profile with <1 mm resolution, differential and common-mode
-
Internal, automatic OSLT calibration
-
USB-connected, small, lightweight
-
Flexible display of the measurements
-
Remove effects from fixtures, connectors and cables
-
Emulate eye diagrams with CTLE, DFE and FFE equalization
-
Advanced jitter analysis
-
Up to 65 GHz system bandwidth
-
Up to 130 GBaud detectable baud rate
-
Up to 160 GS/s sample rate
-
Real-time acquisition for testing of coherent modulated optical communications links
-
Built-in dispersion compensation, polarization de-multiplexing, and carrier recovery algorithms
-
Supports DP-QPSK, DP-16QAM, and a wide variety of other PSK and QAM formats
-
Support for custom modulation formats
-
Built-in local oscillator
-
Adaptive calibration – Receiver can be disconnected and reconnected without factory calibration
-
Available in 5MHz, 10MHz, 30MHz, 40MHz, 60MHz, 80MHz, 120MHz, 200MHz, 350MHz and 500MHz models
-
1 channel (5 & 10MHz) or 2 channel (30MHz, 40MHz, 60MHz, 80MHz, 120MHz, 200MHz, 350MHz & 500MHz) options available
-
Max Sampling rate of 125 Msa/s (5MHz & 10MHz), 150 Msa/s (30MHz & 60 MHz) 1.2 Gsa/s (40MHz, 80MHz, 120MHz) and 2.4 Gsa/s (200MHz, 350MHz and 500MHz) models
-
Up to 16-bit vertical resolution (14-bit on 5MHz, 10MHz, 30MHz & 60MHz models)
-
3.5" (5MHz & 10MHz) and 4.3" Touchscreen (30MHz, 40MHz, 60MHz, 80MHz, 120MHz, 200MHz, 350MHz & 500MHz) available
-
Excellent analog and digital modulation types available (AM, DSB-AM, FM, PM, PSK, FSK, ASK and PWM)
Teledyne LeCroy
Teledyne LeCroy is a leading provider of oscilloscopes, protocol analyzers and related test and measurement solutions that enable companies across a wide range of industries to design and test electronic devices of all types. Since our founding in 1964, we have focused on creating products that improve productivity by helping engineers resolve design issues faster and more effectively.
Oscilloscopes are tools used by designers and engineers to measure and analyze complex electronic signals in order to develop high-performance systems and to validate electronic designs in order to improve time to market. Protocol analyzers are tools used by designers and engineers to generate and monitor traffic over high speed serial data interfaces, including DDR, PCI Express, Fibre Channel, Serial ATA, SAS, USB and others. Both products are critical in the development of a wide variety of demanding design applications.
We utilize both of these important product areas in combination to tackle the most demanding serial data test applications, offering tailored solutions to help our customers perfect their chips, interfaces, subsystems and products which utilize these important communications standards. With the explosion in the use of serial data communications technologies in semiconductors, between devices on circuit boards and between computers and peripherals, we are aimed at a growing and important market.
Our oscilloscopes offer a powerful combination of large and informative displays combined with advanced waveshape analysis capabilities typically tailored to enhance the productivity of engineers in specific applications areas such as serial data test, disk drive test and automotive bus analysis.
Headquartered in Chestnut Ridge, New York, LeCroy has sales, service and development subsidiaries in the US and throughout Europe and Asia. LeCroy products are employed across a wide variety of industries, including semiconductor, computer, consumer electronics, military/aerospace, automotive/industrial, and telecommunications.
Contact Details
Headquarters Teledyne LeCroy
700 Chestnut Ridge Road, Chestnut Ridge, NY 10977-6499, USA
Phone: 800-553-2769 or 845-425-2000
Phone Support: 1-800-553-2769
Fax Sales: 845-578-5985
Email Sales: contact.corp@teledynelecroy.com
Email Support: support@teledynelecroy.com (Oscilloscopes, Waveform Generators, Signal Integrity)