New Scale Technologies - M3-LS-3.4-15 linear smart stage and developer’s kit
- All-in-one microstage - no separate controller
- Direct high-level command interface (I2C or SPI)
- USB adapter enables direct connection to PC
- Small: < 32x32x11 mm including controller
- Absolute encoding: high repeatability, no homing
- Low power: 6 VDC, ~5 W (only when moving)
- For integration into battery powered devices
- Long stroke: 15 mm
- High force: 1 N (~100g load vertical, ~200g horizontal)
- High stiffness with crossed roller bearing design
Absolute positioning, quiet operation
The M3-LS-3.4-15 is a direct-drive precision piezoelectric micro stage with embedded controller, designed for integration into compact instruments. With long travel and 100 gram vertical load capacity, it has 0.5 μm resolution for precise, repeatable positioning of optics, probes, sensors and more.
Absolute encoding means there is no need to home the stage on power-up, eliminating errors and disruptions in processes and experiments. It has high stiffness with no gears or backlash.
With quiet operation and no high voltage, M3-LS Smart Stages are superior to piezo inertia (stick-slip) stages especially for near patient instruments and wearable devices.
Embedded controller means “all-in-one” simplicity for smallest size, fastest integration
All drive electronics are integrated right into the stage housing to give product designers the smallest system size and fastest, easiest integration into miniature OEM systems.
The M3-LS-3.4-15 Smart Stage accepts simple high-level motion commands directly via standard serial interface (I2C or SPI) or via USB with adapter. Control multiple stages from one New Scale Pathway™ software screen. Or use the intuitive script generator to create command sequences for automated operation.
Precision motion in battery-powered systems
The M3-LS-3.4-15 Linear Smart Stage can be powered by standard batteries or any low-cost DC supply. The internal SQUIGGLE® motor holds position with no power. The embedded controller’s sleep mode further reduces power consumption.
Refer to "Datasheets & Downloads" for more specifications.
APPLICATIONS
- Hand-held and battery-powered instruments
- Biomedical devices
- Miniature/embedded microscopes
- Spectroscopy
- Precision opto-mechanical alignment
- Micro manipulation
M3-LS-3.4-15 Specifications |
|
---|---|
Description |
Longer travel, higher load capacity Linear Smart Stage: micro positioning stage with built-in controller |
Travel Range (Stroke) |
15 mm |
Dimensions |
32 x 32 x 11 mm including controller |
Mass of Smart Stage (including controller) |
30 grams including controller 36 grams (+ cable + connector) |
Max Moving Mass (vertical) (note 2) |
100 grams |
Max Moving Mass (sideways and horizontal) (note 2) |
200 grams |
Force (operating) |
1 N |
Speed (at operating force) |
> 4 mm/s |
Duty Cycle |
50% max recommended |
Resolution |
0.5 μm with absolute encoding |
Bi-directional Repeatability |
< 5 μm |
Accuracy |
< 20 μm |
Input Power (note 4) |
6 VDC +/- 5% 5 W typical at 4 mm/s, 1 N load, closed-loop < 0.2 W quiescent |
Static Parallelism |
< 30 μm |
Run-out |
< 10 μm |
Pitch and Yaw |
< 1 mrad |
Absolute Max Load |
10 N |
Linear Slide Features |
Crossed roller bearings with high stiffness |
Relative Humidity |
< 70% |
Operating Temperature (note 5) |
+5 °C to +40 °C |
Storage Temperature |
-40 °C to +85 °C |
Lifetime |
- |
Compliance |
CE / RoHS |
Controller |
Embedded |
Control Interface |
Directly via I2C or SPI serial interface Indirectly via USB adapter to PC |
Note 1: For the M3-LS-U2-8 smart stage, moving mass of the stage carriage without payload is ~6 grams
Note 2: Higher moving mass is possible but affects performance and lifetime
Note 3: For the M3-LS-U2-8 smart stage, torque due to gravity of the payload calculated from center point (see the coordinates in the data sheet PDF) on the carriage is recommended to be within 1.5 Nmm. Also recommend center of gravity of the payload above the carriage surface to be <=15 mm.
Note 4: Power depends on input voltage, speed and load
Note 5: Speed and force reduced at lower temperatures within the range
Note 6: Tested horizontally, with 20 grams load offset 8.75 mm at reverse position
Note 7: Corresponds to 10 million moves with an average random move of 120 µm. Lifetime depends on the application and use case. Please consult the factory to discuss your specific system design.
Note 8: A <50% duty cycle is recommended for operating at room temperature (25 °C or below) and mounting the stage on a surface with a good thermal conduction path to dissipate heat. Please consult NST for when operating at higher ambient temperatures.