IntelliPower - FA00124 Rugged UPS
-
3KVA, 3.0KW Double Conversion, On-Line, Isolated, UPS with 115VAC, 60Hz Input, 120VAC, 60Hz Output, Power Factor Correction, Multiple Relay Contact Status Signals and Internal Automatic Bypass for Navy Shipboard Applications
TYPE | SPECIFICATION |
---|---|
Power Rating | 3000W |
Chassis Configuration | 4U, ≥24"D |
Input Voltage | 115 VAC |
Input Frequency | 50/60 |
Input Connector | Circular Mil |
Output Voltage | 120 VAC |
Output Frequency | 50/60 |
Output Connector | Circular Mil |
Battery Runtime | < 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Hot Swap |
Communication | RS232 |
More Product Information
-
Global Input, Rugged, Rack Mount Double Conversion On-Line Isolated Power Conditioning System with Power Factor Correction
-
Global Input, Rugged, Rack Mount, Double Conversion On Line UPS & Isolated Power Conditioning System with Frequency Conversion, Auto-select Input Voltage Select, Power Factor Correction, Front Panel Hot Swap Battery & SNMP Communications for Military Applications in a 1U Enclosure
-
AC Input UPS with internal batteries, extreme high temperature rugged rack mount double conversion on line UPS 72VDC in and 120VAC out at 60Hz with for Industrial Applications in a 2U enclosure
-
450VA, 300W, Isolated, Global Auto-Select, 120/240VAC at 50/60Hz Input and 120VAC at 60Hz Output, Double Conversion Rugged, Extreme Temperature On Line UPS with Power Factor Correction for Military Applications
-
2 strings of 12 ea. 12.8V11AH Lithium Iron Phosphate Batteries, Two Hot Swap Drawers.
-
For use with FA10600, IHT7500RM-5.5KW-220VAC-45-440Hz-Input-ISOL-220VAC-60Hz Out-3U25-EBM24BHS
-
External Battery Pack with 2 strings of 4 each 12V9.6Ah Lithium Iron Phosphate Batteries
-
2 strings of 8 ea 12VHX50 Lead Acid Batteries-Fixed Bracket in Base Line version
-
2500VA, 2000W, Wide Range AC, 50/60Hz Input and 120VAC ,50/60Hz Output, Double Conversion On-Line, High Temperature UPS with 5 each 12V10EB, Lithium Iron Phosphate, Hot Swap Battery Drawer and Power Factor Correction
-
Global Input, Rugged, Rack Mount, Double Conversion, Online UPS & Isolated Power Conditioning System with Frequency Conversion, Auto-select Input Voltage Select, Power Factor Correction, Front Panel Hot Swap Battery & SNMP Communications for Military Applications in a 2U Enclosure
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form