IntelliPower - FA00072 Rugged UPS
-
3000VA, 2.1KW, 115 VAC 50/60 Hz Input, 115 VAC, 60 Hz Output, Frequency Changer, Galvanic Isolation, Power Factor Corrected, Rack Unit, 3U High x 19" Wide x 16.75" Deep, Strain Relieved Power Cables, Rugged, Double Conversion UPS, to Provide Power Conditioning and Battery Hold-up for Shipboard Applications
TYPE | SPECIFICATION |
---|---|
Power Rating | 2100W |
Chassis Configuration | 3U, ≤23"D |
Input Voltage | 115 VAC |
Input Frequency | 50/60 |
Input Connector | Circular Mil |
Output Voltage | 115 VAC |
Output Frequency | 50/60 |
Output Connector | Circular Mil |
Battery Runtime | < 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | None |
Communication | SNMP |
More Product Information
-
1500VA, 1350W, 115VAC at 60Hz Input and 115VAC at 60Hz Output, Double Conversion, Rugged, High Temperature, Isolated Online UPS with Hot Swap Battery Drawer and Power Factor Correction for Navy Shipboard Applications
-
4,000 VA, 3,000 Watt, Dual 115VAC input, 115VAC output UPS with Lead Acid Battery EBP for military shipboard application
-
Rugged, Double Conversion, High Temperature, Isolated, Auto Select, 120 or 240 VAC Global Input & Auto Select, 120VAC Output, On Line UPS System with Power Factor Correction
-
6000 VA, 4500 W, 220 VAC at 60 Hz input and 220 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS. Power factor correction for Navy shipboard applications
-
High Temperature, Double Conversion, Rugged, Online, Rack Mountable UPS with Power Factor Conversion and Aluminum Enclosure
-
2200 VA, 2120 W UPS with 120 VAC Input, 120 VAC and 28 VDC Outputs, Frequency Changer, Isolated, Power Factor Corrected, Hot Swap Tower, 17”H x 7.75”W x 22”D, Rugged, Double Conversion, to Provide Power Conditioning for Navy Applications
-
6600VA, 5800W, 440 VAC 3Ph 60Hz Isolated Input, 220 VAC 1Ph 60Hz Output, Freq Changer, 4U26, L16 20P, L6 30R, SNMP, w/ Anderson EBP, Double Conversion, Rugged, High Temperature, On line UPS with Hot Swap Battery Drawer, and Power Factor Correction
-
IRIG A & B/IEEE-1344, and NASA 36 inputs standard
-
HaveQuick sync option
-
Propagation delay compensation
-
Zero latency time reads
-
Match Time output (P4)
-
IRIG B time code output option
-
External Event time tag (P4)
-
Three user programmable rates
-
Ruggedization option
-
Multi-pin Front Panel P4 I/O option
-
2 strings of 8 ea 12VHX50 lead acid batteries and two hot swap drawers
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form