IntelliPower - FA00041 Rugged UPS
-
Double Conversion, Vertical/Free Standing, Online UPS System with Power Factor Correction
TYPE | SPECIFICATION |
---|---|
Power Rating | 1400W |
Chassis Configuration | 3U, ≤23"D |
Input Voltage | 230 VAC |
Input Frequency | 50/60 |
Input Connector | IEC320 |
Output Voltage | 110 VAC |
Output Frequency | 50/60 |
Output Connector | IEC320 |
Battery Runtime | < 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Fixed |
Communication | RS232 |
More Product Information
-
1500 VAC, 1.05 KW, 120V 50/60 Hz Input, 120V 60 Hz Output, 4 Battery Hot Swap Drawer, 3U High x 20.5" Deep, Double Conversion, Rugged, Isolated, On‐Line Rack Mounted UPS System with Power Factor Correction for Navy Shipboard Applications
-
Rugged, Double Conversion, High Temperature, Galvanic Isolation, Global Input with 120VAC Output. Lead Acid batteries. True On-Line UPS and Power Conditioning/Conversion System with Power Factor Correction for Military Applications in a Rack Mount Enclosure with Front Panel Hot Swap Battery Drawer
-
Fiber optic delay line based test set supports all formats of radio altimeters
-
Portable ruggedized enclosure for flight line or benchtop use
-
Battery operated
-
Simulates static altitudes from 0* ft. to 10,000 ft. in 10 ft. steps (*minimum simulated altitude dependent upon AID and test cable length)
-
+20 dB of power level offset from nominal loop loss value
-
Touch-screen operation
-
Direct-connect to UUT T/R or installed system via antenna couplers
-
6000 VA, 4500 W, 220 VAC at 60 Hz input and 220 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS. Power factor correction for Navy shipboard applications
-
3000VA, 2700W, 115 VAC 60Hz Isolated Input, 115 VAC 60Hz Output, Freq Changer, 8BHS, 2U24.4, L5-30P, L5-20R, SNMP, w/ Anderson EBP, Double Conversion, Rugged, High Temperature, On-line UPS with Hot Swap Battery Drawer, and Power Factor Correction
-
Power Conditioner 3000VA, 3000W, Isolated, 220VAC at 50 Hz Input, and 220VAC at 60Hz Output
-
1500VA, 1000W, 2 EA 115VAC, 60Hz Input & 115VAC, 60Hz, Outputs, Double Conversion, Rugged, High Temperature, Isolated, On -Line UPS System with Hot Swap Battery, Power Factor Correction and Discrete, Parallel Line Communications
-
External battery pack, 4 each 12V10.5Ah battery, 48 VDC Nominal, Hot Swap
-
External Battery Module with 54 Cyclon E-cell Batteries
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com