IntelliPower - FA10469 Rugged UPS
-
3000VA, 2700W, 115 VAC 60Hz Isolated Input, 115 VAC 60Hz Output, Freq Changer, 8BHS, 2U24.4, L5-30P, L5-20R, SNMP, w/ Anderson EBP, Double Conversion, Rugged, High Temperature, On-line UPS with Hot Swap Battery Drawer, and Power Factor Correction
TYPE | SPECIFICATION |
---|---|
Power Rating | 225W |
Chassis Configuration | 2U, ≥24"D |
Input Voltage | 115 VAC |
Input Frequency | 50/60 |
Input Connector | NEMA Type |
Output Voltage | 110 VAC |
Output Frequency | 50/60 |
Output Connector | NEMA Type |
Battery Runtime | < 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Hot Swap |
Communication | SNMP |
More Product Information
![VIAVI - UC-584 Universal Transponder Antenna Coupler VIAVI - UC-584 Universal Transponder Antenna Coupler](/sites/default/files/styles/max_325x325/public/uc-584-series.png?itok=qOMcUti6)
-
Reliable FAR Part 43 Appendix ‘F’ ERP and MTL testing in high multi-path environments
-
Provides >20 dB of antenna isolation for Mode S transponder altitude and diversity tests
-
Reduces interference with air traffic control and nearby aircraft
-
Rugged design for ramp use
-
Fits most ‘Shark Fin’ L-Band antennas
-
Quick action antenna grip/release action
![IntelliPower - FA00056 Rugged UPS IntelliPower - FA00056 Rugged UPS](/sites/default/files/styles/max_325x325/public/fa00056-detail-image.png?itok=l21MBDph)
-
2000 VA, 1400 Watts, Input at 120 VAC (-20% + 15%), 50/60 Hz, Output at 120 VAC, 50/60 Hz follower, Double Conversion, Non Isolated, Rugged UPS with Power Factor Correction
![IntelliPower - FA10127 Rugged UPS IntelliPower - FA10127 Rugged UPS](/sites/default/files/styles/max_325x325/public/10127.png?itok=gb54mwu9)
-
Rugged, Double Conversion, High Temperature, Galvanic Isolation, Global Input with 120VAC Output using Lithium Iron Phosphate Battery Chemistry. True Online UPS and Power Conditioning/Conversion System with Power Factor Correction for Military Applications in a Rack Mount Enclosure
![Luna - os3500 Embeddable Optical Strain Sensor Luna - os3500 Embeddable Optical Strain Sensor](/sites/default/files/styles/max_325x325/public/os3500.png?itok=FW9-UHaC)
-
Ruggedized sensor package, qualified to same rigorous standards applied to electronic gages
-
Integrated temperature compensation FBG sensor
-
Connector protection fittings available for harsh environments
-
Double-ended design supports multiplexing of many sensors on one fiber
-
Patented micro opto-mechanical technology
![IntelliPower - FA10470 Rugged UPS IntelliPower - FA10470 Rugged UPS](/sites/default/files/styles/max_325x325/public/10470.png?itok=lf0Iiott)
-
6600VA, 5800W, 440 VAC 3Ph 60Hz Isolated Input, 220 VAC 1Ph 60Hz Output, Freq Changer, 4U26, L16 20P, L6 30R, SNMP, w/ Anderson EBP, Double Conversion, Rugged, High Temperature, On line UPS with Hot Swap Battery Drawer, and Power Factor Correction
![IntelliPower - FA00123 Rugged UPS IntelliPower - FA00123 Rugged UPS](/sites/default/files/styles/max_325x325/public/fa00123-detail-image.png?itok=Ds6i25BS)
-
3kVA, 2.1kW Double Conversion On-Line Isolated UPS 115VAC, 60Hz Input, 120VAC, 60Hz Output, Power Factor Correction, Multiple Relay Contact Status Signals and Internal Automatic Bypass for Navy Shipboard Applications
-
External Battery Charger
-
2 Stage
-
2 Strings of 7-Battery-84V Nominal Modular Enclosure to be used for recharging external battery packs as a storage and maintenance function
![IntelliPower - FA10203 Rugged UPS IntelliPower - FA10203 Rugged UPS](/sites/default/files/styles/max_325x325/public/10203.png?itok=RqglRgDA)
-
3000VA, 3000W, 120/240VAC 50/60Hz Input and 120VAC 60Hz Output UPS
-
3000 VA, 2500 W, 180-260 VAC at 60 Hz input and 220 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS with hot swap battery drawer, with power factor correction
![intellipower_CNTR](/sites/default/files/styles/max_650x650/public/2024-04/intellipower_CNTR.png?itok=hSHPj12j)
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form