Dualos - NEO Check Valve Bodies
No Internal Valve
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
|
NEO 719F-P-06 |
4 |
0.4375-28 UNJEF Class 3A |
6 |
0.5625-24 UNJEF Class 3B |
1.50 |
0.81 |
|
NEO 720F-P-06 |
6 |
0.7500-16 UNJEF Class 3A |
6 |
0.5625-18 UNJF Class 3A |
1.80 |
1.00 |
| NEO 723F-P-08 |
10 |
0.7500-16 UNJEF Class 3A |
8 |
0.750-16 UNJF Class 3A |
2.03 |
1.13 |
|
NEO 724F-P-16 |
20 |
1.625-12 UNJ Class 3A |
16 |
1.3125-12 UNJ Class 3A |
3.32 |
1.88 |
| NEO 725F-P-08 |
10 |
0.8750-20 UNJEF Class 3A |
8 |
0.750-20 UNJEF Class 3A |
2.03 |
1.13 |
|
NEO 728F-P-06 |
8 |
0.7500-20 UNJEF Class 3A |
6 |
0.5625-24 UNJEF Class 3A |
6.70 |
1.38 |
|
NEO 729F-P-10 |
8 |
0.7500-20 UNJEF Class 3A |
10 |
0.8750-20 UNJEF Class 3A |
6.86 |
1.38 |
*Approximate Dimensions [inches]
More Product Information
- Preparation and Post-Mission Data Retrieval and Replay
- IRIG-106 CH10 Data Replay and Configuration of Display
- Simultaneous Replay of up to 4 Cartridges for Mass Debriefing
With LUMIMAX® LED Coaxial Lights, a highly diffused light field is shown on the object field through a semi-transparent mirror vertical in the optical axis of the camera. The homogeneous and shadow-free lighting is used for surface inspections, completeness checks and printed image inspections. The Coaxial Lights also meet the requirements for standard-compliant reading and verification of two-dimensional codes.
The optical design of Coaxial Lights necessarily reduces the amount of light emitted. By using the latest generation of High Power LEDs, the new LES series can compensate for this effect and illuminate test objects with high light intensity.
- Up to 96 differential channels per full rack mainframe
- Constantly monitor input signals for fault conditions
- Flexible configurations for detecting edges, out-of-bounds conditions and measuring pulse widths
- Inputs can be masked, inverted, and combined to produce interrupts
- Can be used as a time stamp module and as a digital I/O
- Programmable debounce circuitry prevents erroneous readings
- 10 V and 100 V input ranges
- On-board memory stores events with IEEE 1588 timestamps
- Synchronize reading of input states with other scanned analog channels
- Device and operation are according to the standard IEC 60811-506 (IEC 60811-1-4) point 8.5
- Case set offers all required weights for the test
- Easy operation
- Very robust and solid construction
- Steel impact piece included
- Up to 3 Samples can be tested simultaneously
- Device suitable for positioning in a cold chamber - Product No.: 402.0020.02
- Object size / measuring range up to 130 mm (5.11“) (larger customizations are possible)
- Quick and very easy measurement
- Little training required (without a customer specified database an initial operating instruction takes only 15 min)
- Suitable software: VELOX (measuring software), ProCable3 (CAQ system)
- Various external CAQ software are connectable (CIQ-AESA, ADVARIS, QDA-ASI-DATAMYTE, QUASAR, etc.)
- No user influence on default optical focus as well as default optimized, intelligent and homogeneous lighting
- Shock and vibration resistant due to an optimized sensor arrangement and balanced weight distribution
- Quick and very precise measurements due to the robust construction and easy operation
- Measuring software enables various operator level settings (production, laboratory, administrator, service, etc.)
- Standardized individual components lead to supply security and therefore a short delivery period
- Easy connection with external devices
Dualos