EMZER - EMSCOPE, 9kHz - 110MHz, 2 channel Receiver/LISN
EMI Measurements:
- FFT-based dual-channel receiver
- According to CISPR16-1-1
- Peak, Quasi-Peak, and Average Detectors
- Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
- The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)
A fully integrated system for complete measurements of conducted emissions up to 110 MHz. Fast and accurate EMI measurements and innovative Modal measurements (common and differential mode) for an effective filter design.
Emscope: Dual FFT-based Modal EMI Receiver
EMI Measurements:
- FFT-based dual-channel receiver
- According to CISPR16-1-1
- Peak, Quasi-Peak and Average Detectors
- Resolution Bandwidth Filters of 200 Hz, 9 kHz and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
- The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)

Modal Measurements:
- Real-time results (FFT)
- Common- and Differential-Mode measurements
- Speeds up RF filter design and problem solving
- Better device under test (DUT) characterization
- Ideal for R&D
Compact and Cost-effective
- Compact solution easy to move around
- Integrates all items inside one single box:
- 2 channel FFT receiver 2 channel 16A single phase LISN
- Pulse limiter 5W
- Software
- Fiber-optic communication

Software included
- Embedded software with free updates, no installation is required
- Allows EMI and Modal measurements
- Waterfall function included
- Automatic compliance test report (csv, pdf, image)
- Easy results comparison features
- Pre-set EMC measuremets settings
- Oscilloscope mode (optional)


|
Technical Specifications |
|
|---|---|
|
Standard for EMI Test Receiver / LISN |
According to CISPR 16-1-1 / 16-1-2 standards |
|
Conducted-Emissions Frequency range |
EMSCOPE 30: 9 kHz – 30 MHz EMSCOPE 110: 9 kHz – 110 MHz |
|
Detectors |
Peak, quasi-peak and average |
|
Type of measurements |
Physical (line and neutral) and modal (common and differential mode) conducted emissions |
|
Full spectrum measurement time |
Equal to the measurement dwell time, which is totally configurable from 1 s to 15 s |
|
Resolution bandwidth filters |
200 Hz, 9 kHz and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL) |
|
Integrated circuits |
Pre-amplifier and pulse limiter |
|
AMN impedance / Pre-filter Choke |
50 Ω || (50 μH + 5 Ω) / 250 μH |
|
Maximum Continuous Current |
Up to 16 A @ 230 VAC (socket dependent; check user manual) |
|
Maximum Continuous Voltage |
Up to 300 VAC - 325 VDC (socket dependent; check user manual) |
|
Power-Supply Operating Frequency |
DC to 60 Hz |
|
Artificial hand / connector type |
510 Ω + 220 pF / 4 mm banana |
|
Connector for EUT / mains |
Schuko socket (Type F) / IEC C20 |
|
Physical Specifications |
|
|---|---|
|
Height |
195 mm |
|
Width |
252 mm |
|
Depth |
438 mm |
|
Weight |
8.5 kg |