Dualos - Fittings - NEO 801B Series
NEO X01 3000 PSI Adapters
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
D |
|
NEO 801B-P-04 |
4, 12 |
JIC-37 Degree |
4 |
0.4375-20 UNJF Class 3A |
1.21 |
– |
1.45 |
|
NEO 801B-P-06 |
6, 12 |
JIC-37 Degree |
6 |
0.5625-18 UNJF Class 3A |
1.47 |
– |
1.45 |
| NEO 801B-P-08 |
8, 12 |
JIC-37 Degree |
8 |
0.7500-16 UNJF Class 3A |
1.60 |
– |
1.45 |
|
NEO 801B-P-10 |
10, 12 |
JIC-37 Degree |
10 |
0.8750-14 UNJF Class 3A |
1.55 |
– |
1.66 |
| NEO 801B-P-12 |
12 |
JIC-37 Degree |
12 |
1.0625-12 UNJ Class 3A |
1.65 |
– |
1.66 |
|
NEO 801B-P-16 |
12 |
JIC-37 Degree |
16 |
1.3125-12 UNJ Class 3A |
1.79 |
– |
1.92 |
|
NEO 801B-P-20 |
12 |
JIC-37 Degree |
20 |
1.6250-12 UNJ Class 3A |
1.85 |
– |
2.22 |
*Approximate Dimensions [inches]
More Product Information
The VTI Instruments 16-Channel bridge and strain gauge measurement instrument
- 24-bit, delta-sigma ADC, simultaneous sampling
- Programmable Sample Rate up to 128kSPS
- Full, Half & Quarter Bridge with 120Ω, 350Ω & 1kΩ bridge completion
- Voltage Excitation: 0.5V to 10V
- Current Excitation: 0.46mA
- 2-Wire & 4-Wire Ohms/RTD
- Bridge Zero Balancing
- Built-In-Self-Test (BIST)
- Strain Lead Wire Calibration
- Shunt Calibration: 50kΩ, 100kΩ & External provided by User
- TEDS Support
- LXI Ethernet Interface
- IEEE-1588 Synchronization
- Power over Ethernet (PoE) or 10–50 V DC input
- Built-in Parallel Data Streaming
- Full-featured Embedded Web Interface
- Compact 1U Half-rack Form Factor
-
On-Off power switch
-
15 A Circuit Breaker
-
Inlet - IEC C14 for use with any cordset
-
Outlets – (8) IEC C13
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
-
15’ Flexible Power Cord
-
IEC C13 / C14 Connectors
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
- Up to 96 differential channels per full rack mainframe
- Constantly monitor input signals for fault conditions
- Flexible configurations for detecting edges, out-of-bounds conditions and measuring pulse widths
- Inputs can be masked, inverted, and combined to produce interrupts
- Can be used as a time stamp module and as a digital I/O
- Programmable debounce circuitry prevents erroneous readings
- 10 V and 100 V input ranges
- On-board memory stores events with IEEE 1588 timestamps
- Synchronize reading of input states with other scanned analog channels
Dualos