Dualos - Fittings - NEO 605F Series
NEO X05 5080 PSI Adapters
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
D |
|
NEO 605F-P-04 |
4, 12 |
JIC-37 Degree |
4 |
0.4375-28 UNJEF Class 3B |
2.08 |
0.40 |
- |
|
NEO 605F-P-06 |
6, 12 |
JIC-37 Degree |
6 |
0.5625-24 UNJEF Class 3B |
2.19 |
0.49 |
- |
| NEO 605F-P-08 |
8, 12 |
JIC-37 Degree |
8 |
0.7500-20 UNJEF Class 3B |
2.30 |
0.56 |
- |
|
NEO 605F-P-10 |
10, 12 |
JIC-37 Degree |
10 |
0.8750-20 UNJEF Class 3B |
2.45 |
0.66 |
- |
| NEO 605F-P-12 |
12 |
JIC-37 Degree |
12 |
1.0625-18 UNJEF Class 3B |
2.52 |
0.70 |
- |
|
NEO 605F-P-16 |
12 |
JIC-37 Degree |
16 |
1.3125-16 UNJ Class 3B |
2.74 |
0.79 |
- |
|
NEO 605F-P-20 |
12 |
JIC-37 Degree |
20 |
1.6250-16 UNJ Class 3B |
2.87 |
0.98 |
- |
*Approximate Dimensions [inches]
More Product Information
- Two 120/240 V Outlets
- Circuitry rated for 20 A
- 8’ Flexible Power Cord
- Shrouded Safety Banana Jacks
- Stable footprint with non-slip feet
- Measuring device for large extrusion tools up to 35 mm (1.37“) hole diameter
- Automated measurement process
- Focus indicator allows you to easily adjust the focus
- Homogeneous transmitted light illumination - made by iiM GmbH - for the ideal presentation of the area to measured
- The influence of the user is reduced to a minimum
- Robust, ergonomic design
- Ideal addition to the 2-camera system VCPEx+
- Robust case seals against extraneous light
- Central control unit
- Semi-automatic focussing and illumination
- Safe from impacts and vibrations
- Quasi shadow free transmitted light
- Optimal system status for lighting, optics and camera
- A measurement with 2 cameras is possible
- Adjustable operation distance for 2D measurements in laboratories
- Very precise measurement due to high resolution sensors
- Standardised individual components
- Very easy measuring procedure
- Suitable software VELOX and CAQ-System ProCable available
-
On-Off power switch
-
20 A Circuit Breaker
-
Inlet - NEMA L6-20
-
Outlets – NEMA L6-20R
Test Tap:
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
- On-Off power switch
- 20 A Circuit Breaker
- 8’ Flexible Power Cord
- Outlets – (4) 5-20R
Test Tap:
- 3ft.
- (2) fork terminals (current)
- (1) fork terminals (ground)
- (2) Shielded Banana (voltage)
- Up to 96 differential channels per full rack mainframe
- Constantly monitor input signals for fault conditions
- Flexible configurations for detecting edges, out-of-bounds conditions and measuring pulse widths
- Inputs can be masked, inverted, and combined to produce interrupts
- Can be used as a time stamp module and as a digital I/O
- Programmable debounce circuitry prevents erroneous readings
- 10 V and 100 V input ranges
- On-board memory stores events with IEEE 1588 timestamps
- Synchronize reading of input states with other scanned analog channels
- 2 in 1: device contains the Hot Set Test as well as the Heat Pressure Test
- Robust and compact set including the device and an equipment case
- Possibility to attach a thermometer directly near the sample
- Measurement according to the cable standards IEC 60811 -507 (Hot Set Test) and IEC 60811 -508 (Heat Pressure Test) regarding sample attachment and weight attachment
- Precise choice of weights due to practical containers
- Simultaneous measurement of up to 3 cable or tube samples
Dualos
Website
787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines. 3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors