Sorensen - XDL Series II - 105W - 215W Digitally controlled linear benchtop DC power supply
- Multiple voltage⁄current ranges
- Direct numeric entry and incremental rotary control of voltage and current
- The remote or local sense
- Illuminated keys and display legends.
- Up to ten store/recall set-ups (30 setups for triple output)
- Power output display
- Link and copy mode
The Sorensen XDL series II bench power supply represents the "next generation" of high-performance laboratory DC power supplies.
The XDL DC bench power supply provides multiple ranges for increased current capability at lower voltages and uses pure linear technology.
Unlike other digitally controlled units, the XDL series II lab power supply provides both numeric and rotary control while the illuminated keys and display legends provide instant confirmation of settings and status.
For added convenience, the Sorensen XDL series II bench power supply provides storage of up to 10 power supply set-ups in non-volatile memory (30 set-ups for a triple). There are also fully adjustable over-voltage and over-current trips. The XDL series II also provides full remote sense capability via dedicated sense terminals.
The XDL triple output model features link and copy mode for convenience. When linked, the keyboard and jog wheel control operate both outputs simultaneously. The copy function copies all settings for output 1 to output 2.
Protection
- Over voltage protection
- Over current protection
- Over temperature protection
- Sense protection
Output : Voltage and Current |
|||
---|---|---|---|
Model |
Output Range |
Output Range 2 |
Output Range 3 |
35-5 |
1 0-35 V, 0-3 A |
0-15 V, 0-5 A |
0-35 V, 0-500.0 mA |
35-5T |
0-35 V, 0-3 A |
0-15 V, 0-5 A |
0-35 V, 0-500.0 mA |
35-5P |
0-35 V, 0-3 A |
0-15 V, 0-5 A |
0-35 V, 0-500.0 mA |
35-5TP |
0-35 V, 0-3 A |
0-15 V, 0-5 A |
0-35 V, 0-500.0 mA |
56-4 |
0-56 V, 0-2 A |
0-25 V, 0-4 A |
0-56 V, 0-500.0 mA |
56-4P |
0-56 V, 0-2 A |
0-25 V, 0-4 A |
0-56 V, 0-500.0 mA |
56-4TP |
0-56 V, 0-2 A |
0-25 V, 0-4 A |
0-56 V, 0-500.0 mA |
Model |
Outputs |
Output Power |
Interface (GPIB/RS-232/USB) LAN-LXI |
---|---|---|---|
35-5 |
1 |
105 W |
No |
35-5T |
3 Aux, 1-6 V, 3 A |
215 W |
No |
35-5P |
1 |
105 W |
Yes |
35-5TP |
3 Aux, 1-6 V, 3 A |
215 W |
Yes |
56-4 |
1 |
112 W |
Yes |
56-4P |
1 |
112 W |
Yes |
56-4TP |
3 Aux, 1-6 V, 3 A |
112W |
Yes |
Voltage Setting |
By floating point numeric entry or rotary jog wheel; resolution 1mV |
||
Current Setting |
By floating point numeric entry or rotary jog wheel; resolution 1mA or 0.1mA depending on range |
||
Voltage Setting |
Resolution 1mV Accuracy ± (0·03% + 5mV) |
||
Current Setting |
Resolution 1mA; 0·1mA on 500mA range Accuracy ± (0·2% + 5mA); ± (0·2% + 0·5mA) on 500mA range. |
||
Output Mode |
Operation in constant voltage or constant current modes with automatic cross-over and mode indication by LEDs. |
||
DC Output Mode Switch |
Sets output voltage and current levels to zero when Off. |
||
Output Terminals |
4 mm terminals on 19 mm (0.75”) spacing |
||
Load Regulation |
Voltage: < 0.01% + 2 mV Current: < 0.01% + 250 μA; < 0.01% + 50 μA on 500 mA range (measured at output terminals using remote sense) |
||
Line Regulation |
Voltage: < 0.01% + 2 mV for 10% line change Current: < 0.01% + 250 μA; < 0.01% + 50 μA on 500 mA range |
||
Ripple and Noise |
Typically < 0.35% Vrms 2 mVp-p CV mode, and < 0.2 mArms, < 20 μArms (500 mA range) CI mode |
||
Transient Response |
50 μs to within 15 mV of set level for a change in load current from full load to half load or vice versa |
||
Temperature Coefficient |
<± (50 ppm + 0.5 mV) / °C (voltage) |
||
Remote Sense |
Eliminates up to 0.5 V drop per lead. Remote sense operation selected from front panel and indicated by LED |
||
Sense Terminals |
Recessed sprung sockets for direct insertion of wires. Duplicated on rear terminal block (P versions only) |
General Specifications |
|
---|---|
Operational AC Input Voltage |
115 V or 230 V ± 10% (adjustable internally, option HV for factory set 230 Vac input), 50/60 Hz. Installation Category II |
Operating Temperature Range |
5 to 40°C, 20% to 80% RH |
Storage Temperature Range |
- 40 to 70°C |
Dimensions ( H x W x D) |
6.3 x 5.5 x 11.4” (160 x 140 x 290 mm) (XDL 35-5, XDL 35-5P, XDL 56-4, XDL 56-4P), 6.3 x 11.0 x 11.4” (160 x 280 x 290 mm) (XDL 35-5T, XDL 35-5TP, XDL 56-4T, XDL 56-4TP) |
Weight |
11.9 lb (5.4 kg) (XDL 35-5, XDL 56-4) 12.1 lb (5.5 kg) (XDL 35-5P, XDL 56-4P) 23.1 lb (10.5 kg) (XDL 35-5T, 56-4T) 23.3 lb (10.6 kg) (XDL 35-5TP, 56-4TP) |
Benchtop Operation |
Folding legs are incorporated that can be used to angle the front panel upwards when required |
Rack Mount Operation |
19-inch 4U mount for up to three single output units or one triple, plus one single Blanking plates available for unused sections |
Approvals |
CE-marked units meet: EN61010-1 and EN61326 |
Specifications subject to change without notice. |