Safran DSI - Mission Ground Station Transportable & Rugged Benchtop Whole Station
- Preparation and Post-Mission Data Retrieval and Replay
- IRIG-106 CH10 Data Replay and Configuration of Display
- Simultaneous Replay of up to 4 Cartridges for Mass Debriefing
Our Ground Station is a turnkey ground segment solution with all required equipment and ground tools to proceed with removable media preparation and post-mission data retrieval and replay.
Key components are:
- Rugged Heavy-Duty Laptop for military environment
- RMM (Removable Memory Module) Docking Stations capable of reading up to 4 cartridges simultaneously, especially useful for mass debriefing.
- Ground software suite (RMM Manager, eZ Viewer, MUST), very intuitive and user-friendly interface, for replay and exploitation of data while allowing customizable configuration of the display for mission debriefing.
- Ruggedized Trolley Suitcase specifically adapted for the transport of the whole Ground Station.
This ground station, tested and approved by Safran before delivery, helps to accelerate the deployment on every integration Labs, Military Bases, and can be safely transported between different locations and environments
More Product Information
- 1-port VNA with frequency options from 150 kHz to 6 GHz
- External PC control enables control of multiple ShockLine MS46121B devices in parallel for excellent multisite throughput
- Very compact package allows for direct connection to the DUT
- Scalar transmission measurements in a (1-to-1) or (1-to-n) configuration
- No on-board data storage eliminates the need for data purging in secure applications
- Standard bandpass time domain with time gating enables easier and faster fault identification
- A common GUI interface within the ShockLine family reduces switching costs between models
- Qualified for Harsh Environments: DO-160, MIL-STD-701, -461, -810
- Designed to Minimize Obsolescence Risk & Management: FPGA-Based Design
- Extremely Low Space Requirements: 5.7 x 2.2 x 1.97' / 1,54 lb
- Remote Control of the Mission Recorder
- Standard Installation - Easy to Handle
- Compatible with the Mission Recorder Series
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Fixed flush and fixed offset short circuit terminations (shorts) are used to establish reference planes in transmission systems and as key elements in the calibration of vector network analyzers (VNAs). Offset shorts can be used for banded calibrations of VNA. Those with the longest offset are often used to evaluate the calibration effectiveness of a VNA by measuring the effective source match after calibration.
A Semi Anechoic EMC Chamber with 3-meter test range ensuring EMC compliance for Emission and Immunity testing. Ferrite and hybrid pyramidal EMC absorbers are combined in a unique pattern within a SmartShield high performance chamber. Operating at a 3m test distance, this chamber is compliant to ANSI C63.4/CISPR-16-1-4 with a Test Volume diameter of 1 to 2 meters.
- Designed for Orbit-Topping and Station-Keeping
- 40% Weight Saving Convention Propulsion
- Excellent Thrust-to-Electrical Power Ratio
- Application specific windows ex works:
- Germanium or Saphire: thermal imaging
- BK7 standard: robust glass with high transmission
- IR mirror: applications in critical temperatures
- Acryl: food industry
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
A precision fixed termination (or load) consists of an immovable, (fixed) termination which, when mated to the end of a trans-mission line or cable, absorbs nearly all of the signal energy traveling toward it. An ideal “matched” condition exists when a termination with an impedance value of Z0, is connected to the end of a transmission line or cable that also has a characteristic impedance of Z0. Such an ideal “matched” condition (one with no mismatch between the termination and its mated line or cable) is critical if a voltage standing wave ratio (VSWR) of 1.0:1 is to be achieved in a system with a 50 or 75 ohm impedance value. Simply put, the more closely the 1.0:1 ratio is approached, the more accurate the measurements that can be made from a system.
- STC and LPDC: Space Time Coding and LPDC supported, as well as many advanced features
- CH. 10 & IRIG218-20 Output: Easy and Modern UDP Data Spreading
- DQM/DQE: Embedded data Quality Metrics / Encapsulation compatible with Best Source Selector
- Front Panel Controls: 3 TFT Color Screen and Keyboard on Equipment, and Full Control from External KVM
- EQ+: Adaptive Equalizer for all Modulations, on Video and PCM outputs
- Fast Set Up/Teardown: Single tool for mounting less than one (1) hour
- Field Maintenance: Made out of LRU parts for easy maintenance and repair
- MIL Standard Compliant: Easy handling
- Standard Shipping: Portable boxes shipped via FedEx, UPS, ...
- Designed for Field Operations: Air cooling free, auto North alignment, auto ground compensation
Safran DSI
Safran DSI Testing & Telemetry provides complete, end-to-end solutions covering instrumentation, mission systems, onboard recording, and transmission, through to base stations for data monitoring and control. Our solutions are platform-agnostic and adaptable to customer mission needs.