Safran DSI - L/S/C Tri-Band Feed for Antenna Dishes from 6 to 24 ft
- LTE/4G Mitigation: LTE/4G, WCS & Customized Rejection Filters (Upgradable During Antenna Lifetime)
- Easy Integration: Tri-Band even with Dishes as Small as 6’/1.8m
- SCM 1000 Hz Scan Rate: Highest Accuracy of Tracking
- No RF-Band Compromise: Concentric 3-Band Feed, without need of Dichroic Filter
- Modular L - S or C-Band: Simple Add-On upgrade without any Structural Change
Our patented miniaturized L/S/C Tri-Band Feed delivers top-notch performance and unmatched flexibility.
Equipped with a common L/S/C radiating front end, it’s complemented by a modular set of active RF modules, enabling simultaneous reception and tracking across various frequency bands. Its compact, lightweight design allows it to be mounted on any dishes ranging from 6 to 24 feet.
Available in single, dual, or tri-band configurations, this feed offers the best value for customers looking to meet current requirements while staying future-ready.
It’s also field-upgradable to add any missing bands with straightforward RF module additions, ensuring scalability while keeping costs in check.
More Product Information
- Qualified for Harsh Environment: DO-160, MIL-STD-704, -461, -710
- User-Configurable Interface Combination: One 1000Base-SX port plus combination 1000Base-T and 100Base-T ports
- Fully Managed Operation: Supports IPv4/IPv6, VLAN, IGMP filtering
- Configuration via Dedicated Ethernet Port: RJ-45 Connector
- Advanced Quality of Service: Per IEEE 802, 1p
- 2-port VNA with frequency options from 1 MHz to 8 GHz / 20 GHz / 43.5 GHz (options for 20, 50, and 100 meters)
- Extend remote ports 100 meters apart with PhaseLync synchronization
- Small and lightweight ports enable direct connection to DUT eliminating long cable runs
- Guaranteed performance to 43.5 GHz with Extended-K™ ports
- PC control takes advantage of external computer processing power and functionality
- No on-board data storage makes use in secure applications more convenient
- Common ShockLine control software delivers powerful debug and test capabilities
- PhaseLync control module MN25132A
- Modular
- Control up to 95 assets
- Control multiple AC and DC power supplies and loads in one mainframe
- Create “virtual assets”
- Web browser control
- User configurable
- Highest Power Density
- Simple integration
- PFC
- Universal AC/DC input
- Up to 6kW in one mainframe
- 1kW DC modules
- PFC ≥0.95
- Reduced space and logistics hassles
- High power density
- Handles DC and AC power and load modules
- User configurable
- Universal AC/DC input
- Ease of integration
- Web browser control
- Trigger bus
- Configure modules to parallel or series operation “on the fly”
20 ppm calibrator of DC process signals designed for calibration of evaluation units and process multimeters under demanding industrial conditions. Includes RTD and resistance source.
- 20 ppm accuracy
- 13°C - 33°C reference temp. range
- 100 V @ 25 mA output capacity
NoiseKen simulators to reproduce fast rise-up noises which are generated when switching ON / OFF electric current on the inductive load.
Since the pulse includes broadband frequency and its rise-up time is fast at 3ns or less, it can make the noise coupling dense and effective to reproduce the malfunctions of electronics equipment under the test.
It can realize performance evaluation of electronics equipment's upon reproduction of line noises which are intruded to the power supply lines or induced noises onto the telecommunication lines.
High-voltage/current Probes
- On-wafer power device characterization up to 10,000 V DC / 600 A
- Reduced probe and device destruction at high currents up to 20 A DC and 300 A pulse
- Increased isolation resistance and dielectric strength to provide full triaxial capability at high voltage (3,000 V) for low-leakage measurement
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Coaxial air lines are air-dielectric transmission lines with highly accurate dimensions that can be used as fundamental impedance standards in measurement and calibration applications, and may also be used to establish reference positions for measurements.
Bead supported air lines offer greater convenience and easier connections (the center conductor is automatically aligned by the dielectric bead for easy connection); beadless air lines offer better impedance and electrical length accuracies, as well as lower VSWR (the center conductor floats free in the air line body, and the male connector nut is retractable to facilitate insertion of the center conductor contact before the thread- on connection tightened.
9 ppm AC/DC multifunction calibrator for multimeters , power meters and generally all kinds of electric meters. Implementing modular design, 9010+ can be further customized to calibrate oscilloscopes, insulation testers, sources and transducers.
- 9 ppm accuracy
- 400 MHz and 1.1 GHz scope options
- Power quality functions, voltage from current
Southwest Microwave connectors and accessories are designed to be compatible with each other to assure electrical performance. Southwest Microwave cannot assure electrical performance when the accessories are used with a non-Southwest Microwave connector.
Safran DSI
Safran DSI Testing & Telemetry provides complete, end-to-end solutions covering instrumentation, mission systems, onboard recording, and transmission, through to base stations for data monitoring and control. Our solutions are platform-agnostic and adaptable to customer mission needs.