Maury MW - VNA Calibration Standard - Mismatch Airline Series
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.
|
Frequency Range |
Impedance |
|---|---|
|
DC to 50 GHz |
25 and 75 ohm |
More Product Information
- Additive white Gaussian noise
- Integrated amplifier
- Manual attenuator
- NC6000A -BER testing, and SNR applications
- NC8000A – Secure signal jamming
- Military Applications
- Custom configurations available (consult factory)
The NC6000A and NC8000A Series instruments are designed for general-purpose noise applications on the bench, or in a rack test station. The manual controls make it simple to operate and reduce test set up time. Standard units can be modified for specific customer requirements. Please consult the factory for pricing and availability of these requests.
- 1-port VNA with frequency options from 1 MHz to 8 GHz / 20 GHz / 43.5 GHz
- Guaranteed performance to 43.5 GHz with Extended-KTM ports
- PC control takes advantage of external computer processing power and functionality
- Small and lightweight package enables direct connection to the DUT
- No on-board data storage eliminates the need for data purging in secure applications
- All ShockLine VNAs share common software supporting GUI and program compatibility
- Time domain with time gating option enables easier and faster fault identification
- Simultaneous Sweep enabling users to operate multiple (up to four) MS46131A VNAs concurrently in independent software instances, unlocking true parallel measurement execution
Single phase electric power/energy calibrator for calibration and testing of power meters and power transducers. Terminals 2 and 3 are inactive.
- 0.01° phase shift accuracy
- 15 - 1000 Hz output
- Built-in multimeter for transducer calibration
- Floating current output for 3-wire power meters
- Voltage from Current function
- Single or dual-channel display
- Agilent HP 437 & Agilent HP 438, and Boonton 4220A & 4230A emulation
- Automatically loads sensor data
- Simple software control via SCPI language
- IEEE-488 and RS-232 interfaces standard
The 4240 series of CW RF power meters provides the high speed measurement capability needed in a production environment, as well as the simplicity of operation required for bench top use. It provides very accurate measurements from -70 dBm to +44 dBm (sensor dependent) and has a rapid display update rate for tuning applications. The easy to read LCD displays both channels simultaneously with numeric and bar graph information.
- Capture/display/analyze peak and average power
- Frequency range from 4 kHz to 40 GHz
- Industry-leading video bandwidth (195 MHz) and rise time (3 ns)
- Industry-leading 100,000 measurements per second
- Industry-leading 100 ps time resolution
- Synchronous multi-channel measurements (up to 4 channels)
- Sensors can be used as standalone instruments
-
Ease of use – Less experienced operators can perform an RF calibration up to 500 GHz by simply pushing a button. This reduces the need of experienced users full time on each system.
-
Reduced Soak Time – The system will automatically re-align the probes to the pads if they drift from alignment. This reduces test time and increases throughput.
-
Unattended Use – Measurements can be left running over night or the weekend, testing all devices on the wafer, and at different temperatures without the need of an operator.
-
Calibration Monitor and Re-calibration – System will continuously monitor calibration drift, and automatically re-calibrate the system should the drift exceed a predefined limit.
Three Probe Technologies
- Infinity Probe: best for Al (Si)
- ACP Probe: best for AU (III-Vs)
- |Z| Probe: robust solution (long lifetime)
- Precision contact on a wide variety of materials from 26 GHz to 67 GHz
- Accurate results with excellent crosstalk
- Matching cables and substrates included
Precise Contact Solution
- RF chuck ±3 μm surface planarity
- Unique 500 μm platen contact/ separation stroke with ≤± 1 μm accuracy for repeatable contact
- Precision probe alignment
- Consistent contact force and overtravel
- Stable contact performance
WinCal Calibration Software
- Exclusive 1-, 2-, 3-, and 4-port on-wafer calibration algorithms
- Automated calibration monitoring
- Unique measurement & analysis methods
- Accurate S-parameter measurements
- Automatic calibration setup for higher efficiency
- Fast and easy data interpretation and reporting
65 ppm AC/DC multifunction calibrator designed specifically for calibration of 3½ and 4½ digit multimeters. 1050 V, 20.5 A, resistance, capacitance and temperature packed inside ultra portable, 11 kg body.
- Compact, light, ideal for onsite calibrations
- 1050 V, 20.5 A, resistance, capacitance, TC, RTD and frequency
- Basic accuracy 60 ppm
- All-round calibrator for 3.5 and 4.5 digit multimeters
- Guaranteed performance to 43.5 GHz with Extended K™ ports
- High output power allows measurement of high attenuation devices
- Wide dynamic range enables measurement of very low reflection artifacts
- Excellent corrected directivity minimizes measurement uncertainty
- SmartCal™ auto calibration unit reduces calibration and setup time
- Time domain with time gating option grants easier and faster fault identification
- Modern LAN interface for remote control is faster than GPIB
- A common GUI and SCPI interface within the ShockLine family
- Bias tee option simplifies test setups where the DUT needs DC biasing
- Universal Fixture Extraction (UFX) software option provides advanced de-embedding tools for test fixture extraction
- E-Band VNA
- Extended frequency range covering E-band and major parts of V band
- Fully assembled test system eliminates setup errors and increases reliability
- Tethered modules connect directly to the DUT increasing measurement stability
Maury Microwave
Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.