Maury MW - VNA Calibration Standard - Mismatch Airline Series
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.
|
Frequency Range |
Impedance |
|---|---|
|
DC to 50 GHz |
25 and 75 ohm |
More Product Information
20 ppm calibrator of DC process signals designed for calibration of evaluation units and process multimeters under demanding industrial conditions. Includes RTD and resistance source.
- 20 ppm accuracy
- 13°C - 33°C reference temp. range
- 100 V @ 25 mA output capacity
- Ultra-low distortion signal path
- Standard connectors SMA female
- 7” touch screen display
- Dimensions: 17.22 in. wide x 6.30 in. including feet, high x 19.5 in. deep
- Fold-down feet for bench top use
- Power 115 VAC, 60 Hz
- Operating Temperature: -10° to +65°C
- Differential inputs and outputs
- Multiple differential inputs and outputs
Not all amplifiers are created equal, so how can you be certain that an amplifier will work for your needs? You deserve to be confident that the amplifiers used with your test-and measurement lab benches will meet the requirements of your specific applications, are reliable, and are equally well-supported pre-and post-sale. When it comes to application expertise, reliability and support, there is no company that does it better than Maury.
Bank of fixed resistance, capacitance and inductance standards with defined frequency characteristic up to 1 MHz for automated calibration of LCR meters.
- Automated RCL calibration
- Calibration data from 20 Hz to 1 MHz
- No need for pen and paper method
Software for calibration automation. Available with CamOCR Camera Readout module. Caliber can run autonomous calibrations through remote control or provide guidance to operator in manual mode. Calculated results and uncertainties can be exported to WinQBase or third party software.
- Automatic calibration of instruments
- In line with ISO17025 and other metrology standards
- Automated optical readout module for multimeters
- Users are free to add any custom standard or DUT
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Coaxial air lines are air-dielectric transmission lines with highly accurate dimensions that can be used as fundamental impedance standards in measurement and calibration applications, and may also be used to establish reference positions for measurements.
Bead supported air lines offer greater convenience and easier connections (the center conductor is automatically aligned by the dielectric bead for easy connection); beadless air lines offer better impedance and electrical length accuracies, as well as lower VSWR (the center conductor floats free in the air line body, and the male connector nut is retractable to facilitate insertion of the center conductor contact before the thread- on connection tightened.
- 5” touch screen display
- Noise output through female N connector
- Ethernet connection for remote control
The NGX1000 programmable noise generator is a high performance, broadband additive white gaussian noise (AWGN) generator in an easy-to-use compact form factor. The streamlined user interface and flat menu structure provides a fast, simple way to add RF noise in a communications system to test reliability, robustness and performance.
All functionality of the generator is accessible through the 5” touch screen or via remote control through an ethernet connection delivering flexible, programmable noise generation for broad use in semiconductor, military, aerospace, satellite, medical and communications applications.
- Automatic calibration for the whole test frequency range
- Application of all test frequencies automatically. The level can be selected or automatic.
- NO need to manually configure the measurement equipment
- NO need to manually integrate the transfer function of probes and attenuators
- Generation of test reports: NO need to record all values read from the measurement equipment
- Generation of calibration reports: NO need to record all calibration setting parameters
- Rack together and add CS101, CS109, and RS101 (sections 18, 19, and 20 of the RTCA DO-160G are also available.)
- Autonomous Modal Parameter Estimation Procedure
- Multiple Live Parameter Estimation Windows
- Task Oriented, Easy-To-Use Interface
- Logical Operation Always "One-Click" away
- Simplified "Copy & Paste" Data Management
- Simplified Units Unification Tool
- Based on MATLAB® Computational Engine Environment
- Universal File Format (UFF) Data Access
- Individual Data Channel Calibration
Maury Microwave
Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.