Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.
|
Frequency Range |
Impedance |
|---|---|
|
DC to 50 GHz |
25 and 75 ohm |
More Product Information
Not all amplifiers are created equal, so how can you be certain that an amplifier will work for your needs? You deserve to be confident that the amplifiers used with your test-and measurement lab benches will meet the requirements of your specific applications, are reliable, and are equally well-supported pre-and post-sale. When it comes to application expertise, reliability and support, there is no company that does it better than Maury.
Not all amplifiers are created equal, so how can you be certain that an amplifier will work for your needs? You deserve to be confident that the amplifiers used with your test-and measurement lab benches will meet the requirements of your specific applications, are reliable, and are equally well-supported pre-and post-sale. When it comes to application expertise, reliability and support, there is no company that does it better than Maury.
Single phase electric power/energy calibrator for calibration and testing of power meters and power transducers. Terminals 2 and 3 are inactive.
- 0.01° phase shift accuracy
- 15 - 1000 Hz output
- Built-in multimeter for transducer calibration
- Floating current output for 3-wire power meters
- Voltage from Current function
- 600 MHz of instantaneous bandwidth per channel
- Timing synchronization up to 16 channels
- Link Emulation including:
- Phase continuous delay, Doppler, and attenuation changes
- AWGN and Eb/No
- 12 tap (path) multipath fading with Rayleigh, Rician & CW. Angle of Arrival (AOA), k-factor, and correlation controls
- RF frequency agile up/down converters
- Payload Emulation including:
- IMUX/OMUX amplitude and group delay distortion
- Amplifier Compression (AM/AM and AM/PM)
- Phase Noise
- Static and dynamic link emulation
- Ephemeris data generation using SATGEN
- Remote instrument control through ACEClient application
Not all amplifiers are created equal, so how can you be certain that an amplifier will work for your needs? You deserve to be confident that the amplifiers used with your test-and measurement lab benches will meet the requirements of your specific applications, are reliable, and are equally well-supported pre-and post-sale. When it comes to application expertise, reliability and support, there is no company that does it better than Maury.
- 1-port VNA with frequency options from 150 kHz to 6 GHz
- External PC control enables control of multiple ShockLine MS46121B devices in parallel for excellent multisite throughput
- Very compact package allows for direct connection to the DUT
- Scalar transmission measurements in a (1-to-1) or (1-to-n) configuration
- No on-board data storage eliminates the need for data purging in secure applications
- Standard bandpass time domain with time gating enables easier and faster fault identification
- A common GUI interface within the ShockLine family reduces switching costs between models
The VTI Instruments 16-Channel bridge and strain gauge measurement instrument
- 24-bit, delta-sigma ADC, simultaneous sampling
- Programmable Sample Rate up to 128kSPS
- Full, Half & Quarter Bridge with 120Ω, 350Ω & 1kΩ bridge completion
- Voltage Excitation: 0.5V to 10V
- Current Excitation: 0.46mA
- 2-Wire & 4-Wire Ohms/RTD
- Bridge Zero Balancing
- Built-In-Self-Test (BIST)
- Strain Lead Wire Calibration
- Shunt Calibration: 50kΩ, 100kΩ & External provided by User
- TEDS Support
- LXI Ethernet Interface
- IEEE-1588 Synchronization
- Power over Ethernet (PoE) or 10–50 V DC input
- Built-in Parallel Data Streaming
- Full-featured Embedded Web Interface
- Compact 1U Half-rack Form Factor
Not all amplifiers are created equal, so how can you be certain that an amplifier will work for your needs? You deserve to be confident that the amplifiers used with your test-and measurement lab benches will meet the requirements of your specific applications, are reliable, and are equally well-supported pre-and post-sale. When it comes to application expertise, reliability and support, there is no company that does it better than Maury.
-
Ease of use – Less experienced operators can perform an RF calibration up to 500 GHz by simply pushing a button. This reduces the need of experienced users full time on each system.
-
Reduced Soak Time – The system will automatically re-align the probes to the pads if they drift from alignment. This reduces test time and increases throughput.
-
Unattended Use – Measurements can be left running over night or the weekend, testing all devices on the wafer, and at different temperatures without the need of an operator.
-
Calibration Monitor and Re-calibration – System will continuously monitor calibration drift, and automatically re-calibrate the system should the drift exceed a predefined limit.
Maury Microwave
Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.