Maury MW - Manual Noise Generators - NC6000A-8000A Series
- Additive white Gaussian noise
- Integrated amplifier
- Manual attenuator
- NC6000A -BER testing, and SNR applications
- NC8000A – Secure signal jamming
- Military Applications
- Custom configurations available (consult factory)
The NC6000A and NC8000A Series instruments are designed for general-purpose noise applications on the bench, or in a rack test station. The manual controls make it simple to operate and reduce test set up time. Standard units can be modified for specific customer requirements. Please consult the factory for pricing and availability of these requests.
|
Output |
Attenuator Range |
Impedance |
Typical VSWR |
|---|---|---|---|
|
White Gaussian noise up to 26.5 GHz |
0 to 10 dB in 1 dB steps |
50 Ohms |
1.5:1 |
More Product Information
Not all amplifiers are created equal, so how can you be certain that an amplifier will work for your needs? You deserve to be confident that the amplifiers used with your test-and measurement lab benches will meet the requirements of your specific applications, are reliable, and are equally well-supported pre-and post-sale. When it comes to application expertise, reliability and support, there is no company that does it better than Maury.
- Broadband coverage
- Extremely good temperature stability
- Superior voltage stability
- Noise figure meter-compatible
The NC346 Series is designed for precision noise figure measurement applications. Each module’s low VSWR reduces multiple reflections and significantly increases the measurement accuracy for most noise figure test configurations.
- Additive white Gaussian noise
- Integrated amplifier
- Manual attenuator
- NC6000A -BER testing, and SNR applications
- NC8000A – Secure signal jamming
- Military Applications
- Custom configurations available (consult factory)
The NC6000A and NC8000A Series instruments are designed for general-purpose noise applications on the bench, or in a rack test station. The manual controls make it simple to operate and reduce test set up time. Standard units can be modified for specific customer requirements. Please consult the factory for pricing and availability of these requests.
Flexibility
- Different substrate carriers for wafers up to 100 mm or single dies
- Up to six positioners
- Use with liquid nitrogen or helium, depending on the target temperature
- Probing with an open chamber lid possible under atmospheric condition
- Specially designed for laboratory environments
- Covers wide range of measurements (I-V, C-V, RF, MEMS, OPTO)
See "Specifications & Details" tab for more key features
- Wide Input Bandwidth
- Input Isolation
- Automatic & Manual Changeover
- Transformer Coupled Outputs
- Twenty four Outputs
- Front Panel Status Indicators
- Fault Discrete Inputs
- Compact 1U, 19” rack mount
- Expandable frequency range from 18 to 325 GHz
- 2 to 3 times better accuracy
- Automatic Nitrogen purge eliminates helium equipment
- Primary calibration standard
- Radiometer reference source
- SATCOM earth station conformance verifications
- Automatic calibration for the whole test frequency range
- Application of all test frequencies automatically. The level can be selected or automatic.
- NO need to manually configure the measurement equipment
- NO need to manually integrate the transfer function of probes and attenuators
- Generation of test reports: NO need to record all values read from the measurement equipment
- Generation of calibration reports: NO need to record all calibration setting parameters
- Rack together and add CS101, CS109, and RS101 (sections 18, 19, and 20 of the RTCA DO-160G are also available.)
- Automated Absolute and Additive (Residual) Measurements
- Real Time Cross Correlation
- Only analyzer available that allows actual noise floor measurement
- Unparalleled analog performance
- Repeatable data
The HA7162C Real Time Phase Noise Analyzer is the industry leader with respect to proven accuracy, high reliability, automation and flexibility; offering extremely fast measurement speeds to reduce product development time and/or optimize ATE manufacturing throughput.
- Low Noise Amplifier (preamp)
- 9 kHz - 8 GHz
- Typical gain: 27 dB
- Noise Figure: 2.7 dB
Maury Microwave
Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.