Dualos - Fittings - NEO 20X Series
NEO 20X Adapters
|
PSI |
Part Number |
Port Size 1 |
Thread Per AS4375C |
Port Size 2 |
Thread Per AS4370F |
A |
B |
|
4000 |
NEO 204F-X-06-08 |
06 |
0.750-16 UNJF Class 3A |
08. 12 |
0.7500-16 UNJF-3B |
1.18 |
1.00 |
|
5000 |
NEO 205F-X-04-06 |
04 |
0.5625-24 UNJEF Class 3A |
06. 12 |
0.5625-24 UNJEF-3B |
1.01 |
0.56 |
|
3000 |
NEO 206B-P-06-06 |
06 |
0.5625-18 UNJF Class 3A |
06. 12 |
0.5625-24 UNJEF-3B |
2.51 |
1.00 |
|
3000 |
NEO 206F-X-06-06 |
06 |
0.5625-18 UNJF Class 3A |
06. 12 |
0.5625-18 UNJF-3B |
1.69 |
0.81 |
|
3000 |
NEO 207B-P-06-06 |
06 |
0.5625-18 UNJF Class 3A |
06. 12 |
0.5625-24 UNJEF-3B |
1.19 |
1.68 |
*Approximate Dimensions [inches]
**Optional orange paint stripe and 12 “ Lanyard with attached “REMOVE BEFORE FLIGHT’ flag available
More Product Information
- Single or dual-channel display
- Agilent HP 437 & Agilent HP 438, and Boonton 4220A & 4230A emulation
- Automatically loads sensor data
- Simple software control via SCPI language
- IEEE-488 and RS-232 interfaces standard
The 4240 series of CW RF power meters provides the high speed measurement capability needed in a production environment, as well as the simplicity of operation required for bench top use. It provides very accurate measurements from -70 dBm to +44 dBm (sensor dependent) and has a rapid display update rate for tuning applications. The easy to read LCD displays both channels simultaneously with numeric and bar graph information.
- 2 in 1: device contains the Hot Set Test as well as the Heat Pressure Test
- Robust and compact set including the device and an equipment case
- Possibility to attach a thermometer directly near the sample
- Measurement according to the cable standards IEC 60811 -507 (Hot Set Test) and IEC 60811 -508 (Heat Pressure Test) regarding sample attachment and weight attachment
- Precise choice of weights due to practical containers
- Simultaneous measurement of up to 3 cable or tube samples
- Robust and compact design, easy to handle
- Fast, reliable and highly accurate measuring process
- Integrated hardware and software, touch monitor for intuitive operationReliable, high-precision clamping of the test specimen (including conical tools / conical wire guides)
- The highly precise alignment of camera and test object chuck both enable a highly accurate measurement
- No extraneous light influences thanks to measuring behind closed sliding door
All caps ship with Skydrol (BMS3-11) Compatible O-ring Seal. Parts in compliance with all SMOT document requirements.
- 600 MHz of instantaneous bandwidth per channel
- Timing synchronization up to 16 channels
- Link Emulation including:
- Phase continuous delay, Doppler, and attenuation changes
- AWGN and Eb/No
- 12 tap (path) multipath fading with Rayleigh, Rician & CW. Angle of Arrival (AOA), k-factor, and correlation controls
- RF frequency agile up/down converters
- Payload Emulation including:
- IMUX/OMUX amplitude and group delay distortion
- Amplifier Compression (AM/AM and AM/PM)
- Phase Noise
- Static and dynamic link emulation
- Ephemeris data generation using SATGEN
- Remote instrument control through ACEClient application
All plugs ship with Skydrol (BMS3-11) Compatible O-Rings, Viton® Cuff and Four Metal Clamps. Parts in compliance with all SMOT document requirements.
Dualos
787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines. 3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors