Sorensen - XFR Series 2.8 kW Programmable Analog DC Power Supply
- Analog Programming
- Constant Voltage or Constant Current Operation
- LabView® and LabWindows® Drivers
- Standby Mode
- Front Panel Button Preview of Voltage, Current, OVP
- CSA, UL Approvals
XFR Analog DC Power Supplies is the smart choice for research, product development, and production test applications such as R&D, magnet control, product design, ATE, process control, electroplating, and burn-in.
The unique features of XFR DC power supplies make it the best choice for applications where high power and a wide adjustment of output voltage or current are required in a full 19-inch rack package. Choose from ten 2800-watt models.
Zero voltage, or "soft" switching, provides significant benefits. Switching transients are virtually eliminated and noise performance is closer to linear levels. Efficiency is increased, heat generation is decreased, and stress on the switching transistors is reduced - improving reliability (MTBF).
Unlike most competitive products, XFR programmable DC power supply generates full power at full rated current over its total operating range of 0 to 50° C without derating.
XFR variable DC power supply is also designed with excellent thermal management, so units can be stacked in rack mounts without leaving ventilation space between each unit.
**Software Note: M9B GUI requires National Instruments' VISA, RTE, and IVI Engine. Please visit the National Instruments website for download.
Common |
|
---|---|
Switching Frequency |
XFR 2.8 kW: Nominal 31 kHz (62 kHz output ripple); 60 V to 600 V models: nominal 62.5 kHz (125 kHz output ripple). |
Time Delay |
7 sec maximum from power on until output stable |
Voltage Mode Transient Response Time |
< 3 ms for output voltage to recover within 0.5% of its rated voltage after a step change in load current of up to 10% to 90% of rated output |
Maximum Voltage Differential |
±600 Vdc from output to safety ground |
Remote Start/Stop and Interlock |
2.5-15 V signal or TTL-compatible input, selectable logic |
Remote Analog Programming |
Voltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances; 0-5 V, 0-10 V (default) voltage sources |
Remote Analog Monitoring |
Voltage and current monitor outputs 0-5 V, 0-10 V (default) ranges for 0-100% of output |
Remote Programming & Monitoring Accuracy |
1% zero to full scale output for the default range |
Maximum Remote Sense Line Drop Compensation |
5 V / line (Line drop is subtracted from total voltage available at supply output.) |
Front Panel Voltage and Current Control |
10-turn voltage and current potentiometers |
Front Panel Voltage Control Resolution |
0.02% of maximum voltage |
Main Output Connector |
XFR 2.8 kW: 7.5 - 100 V models: nickel-plated copper bus bars with bus bar cover and strain relief; 150V to 600 V models: 4-terminal, wire clamp connector with cover and strain relief |
Approvals |
NRTL approved and CE-marked to UL Std. No. 61010-1, CAN/CSA-C22.2 No. 61010-1-04, EN 610101-1 (Equipment Class I, Pollution Degree 2, Installation Category II) Meets USA EMC standard: FCC, part 15B, Class A; Meets Canadian EMC standard: ICES-001, Class A. |
Input |
|
---|---|
Input Voltage Ranges |
XFR 2.8 kW: 190-264 Vac, 1φ (24.3 A @ 208 Vac; 20.5 A @ 230 Vac typical), 47-63 Hz; Option: M2 3φ 208 Vac input |
AC Input Connector |
Type 3-terminal, 34 A, 250 V, wire clamp connector with strain relief cover |
Protection Features |
---|
Over-voltage Protection |
Over-temperature Protection |
Environmental |
|
---|---|
Operating Temperature |
XFR 2.8 kW: 0 to 50°C, |
Storage Temperature |
-20°C to 70°C |
Humidity (Non-condensing) |
Up to 90% RH, non-condensing |
Physical |
|
---|---|
Model |
XFR 2.8 kW |
Dimensions |
Width: 19” (429.4 mm) Height: 3.5” (88.9 mm) Depth: 21” (533.5 mm |
Weight |
33 lb (15 kg) |