MVG - EMC Dual Ridge Horn Antenna (EH1840) 18000 MHz - 40000 MHz
The EH1840 EMC horn combines stable gain performance and low VSWR with wide band frequency operation. The horn is single linearly polarized with excellent cross-polar discrimination. The unique horn design suppresses any possible excitation of higher order modes in the aperture and maintains a well-defined smooth radiation pattern in the direction of the boresight axis throughout the operational bandwidth.
|
Technical Performance |
|---|
|
Single linear polarization |
|
Smooth / balanced gain with frequency |
|
Low return loss / VSWR |
|
Design |
|---|
|
Precision machined |
|
Stiff/robust and lightweight mechanical design |
|
High reliability k coaxial connector |
|
Equipment |
|---|
|
Storage box |
|
Standard axial mounting interface |
|
Delivered Documents |
|---|
|
Technical Description Document |
More Product Information
All plugs ship with Skydrol (BMS3-11) Compatible O-Rings, Viton® Cuff and Four Metal Clamps. Parts in compliance with all SMOT document requirements.
- 150 MHz, 2 analog channels
- 8 synchronized digital channels (T3AWG2152-D only)
- 16-bit vertical resolution
- 128 MPts @Ch waveform memory
- Max sampling rate of 600 MS/s
An affordable yet high performance solution for all AFG and AWG functions, specializing in key applications such as Automotive Ethernet Transmitter Distortion Test and Double Pulse Testing. The 8 synchronized digital channels (T3AWG2152-D only) are ideal for digital design debugging and validation.
- PowerFlex design provides higher currents at lower voltages enabling one model to meet many different voltage/current requirements.
- Compact design for bench use or rack mounting (1/2 or 1/4 rack width)
- True analog controls with digital settings locking (S-Lock)
- Mixed-mode regulation with linear final regulation for low noise
- Dual models have isolated voltage tracking and synchronous on/off.
- P models have RS-232, USB, and LXI-compliant LAN interfaces plus duplicate rear terminals. GPIB Optional.
- Large surface lighting with dimensions from 50 mm x 250 mm
- Rectangular, square and elongated design in 50 x 50 mm light field modules freely definable depending on requirements
- Lighting solution individually adapted to the application from the cost-optimized standard portfolio
The new modular LUMIMAX® LED Panel Lights expand the lighting portfolio with larger light areas. Thanks to the modular concept, specific sizes can be realized quickly and without additional development costs. The Panel Lights with integrated controller technology are available in different configurations for incident and backlight applications.
- Dual-channel and differential voltage measurements
- 1% accuracy at full scale
- True RMS response below 30 mV
- Optional low-frequency probe for measurements from 10 Hz to 100 MHz
- DC recorder output
- IEEE-488 interface standard, RS-232
The 9240 series is the latest addition to the popular 9200 series of RF voltmeters. It combines accuracy, smart probes, and operator features that have never before been available in its price range. It is simple to use on the bench, and comprehensive enough to integrate into an ATE system. Boonton’s proven voltage probes directly measure from 200 μV to 10 V with usable indication as low as 50 μV and have true RMS response below 30 mV.
- Capability:
- Spectral scan, spatial scan, peak-hold, continuous scanning, spectral and spatial comparison, scripting, limit lines, and report generation.
- Spatial scan time:
- Continuous real-time or sub-second single scan for the entire scan area is dependent on spectrum analyzer performance.
- Spectral scan time:
- 45 seconds for L 10 cm x W 10 cm (L 4” x W 4”) PCB with a 100 MHz span and 100 kHz RBW. Scanning area, span, and RBW are user-selectable within spectrum analyzer specifications
- EMViewer Software
- We recommend you use the EMViewer software for best results. A Yearly subscription or a once-off purchase is available.
- Supported operating systems:
- Windows 10®
- Supported CAD overlays:
- Standard Gerber© RS274x format and HPGL format
-
Combination of DC and RF in a single probe module: One dual probe or a maximum of three RF; a maximum of 9 DC standard (other quantities upon request).
-
Utilizes ACP tip design, GSG, GS or SG
-
RF tips available from DC to 110 GHz
-
Choice of BeCu or tungsten tips
-
DC power needles come standard with 100 pF microwave capacitor
-
Power bypass inductance: 8 nH
-
Maximum DC voltage: 50 V without power bypassing (25 V with standard power bypassing, and component dependent with custom power bypassing)
-
Ideal for probing the entire circuit for functional test
-
Dual ACP configuration supports differential signaling applications
-
DC probes can provide power or slow logic to circuit under test
Microwave Vision Group (MVG)
Testing Connectivity for a Wireless World
The Microwave Vision Group offers cutting-edge technologies for the visualization of electromagnetic waves. With advanced test solutions for antenna characterization, radar signature evaluation and EMC, we support company R&D teams in their drive to innovate and boost product development.
Contact Details
Microwave Vision Group
1320 Air Wing Rd, Suite 101, San Diego, CA 92154, USA
Phone: 678-797-9172