Absolute EMC - Antennas Magnetic
See "Specifications & Details" tab for more information.

|
MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field |
|---|
|
1-120A/m Contiunus testing |
|
100-1100A/m Short Duration 1-3sec |
|
Test either 50Hz & 60Hz Selectable |
|
1m square Loop |

|
Coil Set 4-39_9k-150k EN 61000-4-39 & RS101 9kHz - 150kHz, Tx & Rx Set |
|---|
Low-Frequency Transmit Coil (CAB4-3912) |
|
Frequency: 9 kHz to 150 kHz |
|
Main Diameter: 120 mm |
|
Maximum Current: 15 A |
|
Number of turns: 20 |
Low-Frequency Sense Coil (CABLSLF) |
|
Frequency: 9 kHz to 150 kHz |
|
Diameter to center of the coil: 40 mm |
|
Number of turns: 51 |
|
Wire type: 7/41 LITZ |
|
Winding Type: Electrostatically shielded |

|
MF EASY, DC-400 kHz, MAGNETIC FIELD EXPOSURE ASSESSMENT SYSTEM |
|---|
|
The MF EASY is a scalable and flexible multichannel measurement and assessment system for magnetic fields in the frequency range DC – 400 kHz. It is available with 5 or 10 (on request up to 15) fully isotropic measurement channels enabling simultaneous magnetic field measurements on 5 or 10 (15) measurement positions. Different standard probe types (sizes and shapes) are available for the MF EASY. Customized probes are available on request. Iso-centrically arranged coil and Hall sensor enable a measurement frequency range from DC to 400 kHz and a measurement sensitivity suitable for assessing human exposure. |

|
Coil Set 4-39_150k-26M EN 61000-4-39, 150 kHz - 26 MHz, Tx & Rx Set |
|---|
High-Frequency Transmit Coil (CAB4-3910) |
|
Frequency: 150 kHz to 26 MHz |
|
Main Diameter: 100 mm |
|
Number of Turns: 3 |
|
Wire Diameter: 1mm |
|
Connection type: ‘N’ type Coaxial |
High-Frequency Sense Coil (CABLSHF) |
|
Frequency: 150 kHz to 26 MHz |
|
Diameter to center of the coil: 41 mm |
|
Number of turns: 1 |
|
Wire type: 1mm single core |
|
Winding Type: Electrostatically shielded |

|
Coupling Network for 134kHz |
|
It matches 50 Ohm amplifier |
|
Use with CAB4-3912 loop antenna |
|
Can work with other similar antennas |
|
Type N f-n connectors attached directly to loop |

|
Coupling Network for 13.56 MHz |
|
It matches 50 Ohm amplifier |
|
Use with CAB4-3910 loop antenna |
|
Can work with other similar antennas |
|
Type N f-n connectors attached directly to the loop |

|
The circular transmitting loop antenna |
|
0.01 - 120 MHz |
|
diam. 100 mm |
|
turns 3 |
|
BNC Connectors |

|
Wideband Precision (9 kHz – 30 MHz): Delivers ±1 dB antenna factor stability across the full frequency range. |
|
Long-Life, Low?Noise Operation: Internal NiMH battery pack provides >12 hours of noise-free measurements. |
|
Dual-Field Capability: Supports both magnetic (–31.5 dB Ω·m) and “fictive” electric (20 dB/m) field measurements with one probe. |
|
Rugged, User-Friendly Design: Milled aluminum housing with LED overload indicator and versatile tripod or handle mounting. |

|
8 kHz – 30 MHz Wideband: Delivers ±1 dB antenna-factor accuracy across the full spectrum. |
|
Dual-Mode Measurement: 20 dB/m (E-field) and –31.5 dB Ω·m (H-field) in one compact probe. |
|
Long-Life Battery Operation: NiMH pack provides over 12 hours of low-noise, mains-free measurements. |
|
Overload Protection: Built-in LED indicator alerts you at the 1 dB compression point. |

|
Magnetic, handheld coil |
|
10 kHz - 3 MHz |
|
diam. 133 mm |
|
turns 9 |
|
Immunity testing to VG 95377 Part 13 |

|
Magnetic, handheld coil |
|
DC - 150 kHz |
|
diam. 120 mm |
|
turns 20 |
|
Immunity testing to: ISO 11452-8, MIL 461E RS101, EN 55103 5.18.3.2, IEC 61000-4-39 |

|
FESP 5133 - DC - 200 kHz Radiating Loop |
|---|
|
Magnetic, handheld coil |
|
DC - 200 kHz |
|
diam. 133 mm |
|
turns 36 |
|
Immunity testing to MIL 461, EN 55103 - 2 A.2.1 b), EN 55103 - 2 A.4.1 |

|
Magnetic, handheld coil |
|
DC - 50 kHz |
|
diam. 126 mm |
|
turns 225 |
|
Immunity testing to Measuring Method SF 01 G acc. to VG 95377 |

|
Magnetic, handheld coil |
|
DC - 300 kHz |
|
diam. 500 mm |
|
turns 20 |
|
Immunity testing to EN 55103 - 2 A.3.1 |

|
The Loop Antenna Stand is an advanced antenna support device designed to meet the demands of diverse signal requirements, featuring three primary functions: elevation adjustment, horizontal/vertical orientation, and a 180-degree rotation capability. |

|
Magnetic field monitoring loop |
|
10 - 160 kHz |
|
Diam. 133mm |
|
turns 360 |
|
Emissions testing |

|
Compensation Network |
|
For HFRA 5164 |
|
up to 26 A/m @ 50 Watts |
|
13.56 MHz |

|
3D DC Magnetic Field Sensor Head |
|
Measuring range: typ. max. ± 100mT |
|
Use with HS 3D-Control |

|
Nominal frequency range: DC - 1 kHz |
|
Nominal measuring range: 0 - 7000 A/m |
|
Extended measuring range: 0 - 9000 A/m |
|
Nominal conversion factor: 1 (A/m)/mV |

|
HFRA SF02G - 0.01 - 30 MHz Transmitting Tunable loop antenna |
|---|
|
10 kHz to 30 MHz |
|
acc. to VG95373-13:2008-11 and VG95373-23:2008-11. Including sensor loop HFRAE 5163 and control cable. |
|
diam. 500 mm |
|
2 Turn |
|
16 Watts |

|
Magnetic field monitoring loop |
|
10 - 250 kHz |
|
Diam. 133mm |
|
turns 36 |
|
Emissions testing |

|
Magnetic field monitoring loop |
|
5 - 250 kHz |
|
Diam. 40mm |
|
turns 51 |
|
The level setting for Immunity testing to MIL-STD-461 |
|
Meets requirements of Stellantis CS.00244 2023 ELECTRICAL AND EMC PERFORMANCE REQUIREMENTS FOR E/E COMPONENTS |

|
Magnetic field monitoring loop |
|
10 - 400 MHz |
|
Diam. 40mm |
|
turns 1 |
|
Level setting for Immunity testing to IEC 61000-4-39 |

|
Electromagnet |
|
DC |
|
Diam. 335mm |
|
turns 2000 |

|
Circular Helmholtz Coil |
|
DC - 5 MHz |
|
Diam. 120mm |
|
turns 6 |

|
Circular Helmholtz Coils |
|
DC - 2.5 MHz |
|
Diam. 232mm |
|
turns 9 |

|
Circular Helmholtz Coils |
|
DC - 200 kHz |
|
Diam. 120mm |
|
turns 98 |

|
Circular Helmholtz Coils |
|
DC - 300 kHz |
|
Diam. 232mm |
|
turns 81 |

|
Circular Helmholtz Coils |
|
DC - 500 kHz |
|
Diam. 400mm |
|
turns 12 |

|
Circular Helmholtz Coils |
|
DC - 150 kHz |
|
Diam. 400mm |
|
turns 36 |

|
Circular Helmholtz Coils |
|
DC - 800 kHz |
|
Diam. 600mm |
|
turns 8 |

|
Circular Helmholtz Coils |
|
DC - 500 kHz |
|
Diam. 600mm |
|
turns 16 |

|
Circular Helmholtz Coils |
|
DC - 30 kHz |
|
Diam. 600mm |
|
turns 132 |

|
Square Helmholtz Coils |
|
DC - 150 kHz |
|
Diam. 1.0m |
|
turns 10 |

|
Square Helmholtz Coils |
|
DC - 10 kHz |
|
Diam. 1.0m |
|
turns 100 |

|
Square Helmholtz Coils |
|
DC - 10 kHz |
|
Diam. 1.0m |
|
turns 100 |

|
Square Helmholtz Coils |
|
DC - 150 kHz |
|
Diam. 1.2m |
|
turns 10 |

|
Square Helmholtz Coils |
|
DC - 20 kHz |
|
Diam. 1.3m |
|
turns 50 |

|
Square Helmholtz Coils |
|
DC - 5 kHz |
|
Diam. 1.3m |
|
turns 100 |

|
Square Helmholtz Coils |
|
DC - 100 kHz |
|
Diam. 1.5m |
|
turns 10 |

|
Square Helmholtz Coils |
|
DC - 6 kHz |
|
Diam. 1.5m |
|
turns 100 |

|
Square Helmholtz Coils |
|
DC - 100 kHz |
|
Diam. 1.8m |
|
turns 10 |

|
Square Helmholtz Coils |
|
DC - 5 kHz |
|
Diam. 3m, full vehicle |
|
SAE J551-17 |
|
Turns 100 |

|
Three-Dimensional Helmholtz Coil |
|
DC - 20 kHz |
|
Diam. 1.3m |
|
turns 50 |

|
Compensation Network |
|
For: HHS 5206-16, HHS 5204-12, HHS 5202-9 |
|
up to 32 Arms |
|
DC - 200 kHz |

|
Low inductive precision high power shunt |
|
1 x 0.25 Ohm / 800 W |
|
1 x 1 Ohm / 800 W |
|
2 x 0.5 Ohm / 400 W |
|
Use for many applications including meeting MIL-STD-461 requirements |

|
CP 9610 - DC - 1 MHz Galvanically Isolated Current Sensor |
|---|
|
Galvanically Isolated Current Sensor |
|
It can be used to measure currents in case a shunt is not allowed (Ford EMC-CS- 2009), including 1m RG223/U BNC-BNC |
|
DC – 1 MHz |
|
210 VPK / VDC |
|
-40 A - +40 A |

|
NFCN 9731-100, DC- 180 Hz Compensation Network for HHS 5230-100 |
|---|
|
Compensation Network |
|
For HHS 5230-100 |
|
up to 8 Arms |
|
DC - 180 kHz |

|
NFCN 9732-85, 80 - 90 kHz Compensation Network for HHS 5206-8 |
|---|
|
Compensation Network |
|
For HHS 5206-8 |
|
up to 11 Arms |
|
80 - 90 kHz (85 kHz) |

|
NFCN 9732-120, 50-60 Hz, Compensation Network for HHS 5210-100 |
|---|
|
Compensation Network |
|
For HHS 5210-100 |
|
up to 151 Arms |
|
50 - 60 Hz |

|
Square Helmholtz Coils |
|
DC - 6 kHz |
|
Diam. 1.5m |
|
turns 100 |
|
20A Continuous, 40A 5min |

|
Coil Set 14708-7, Test set for testing to ISO 14708-7 A/B levels |
|---|
|
LF Transmit Coil (CABTL16 & CABTL11) |
|
Frequency: 16.6 Hz - 27MHz |
|
2 loop sets |
|
Meets ISO 14708-7 Criteria A and High B levels |
|
Use 100 Watt Audio amplifier up to 35kHz |
|
Use 150 Watt 50Ohm amplifier 25 kHz - 27 MHz |
|
Magnetic field monitoring loop |
|
10 - 200 kHz |
|
Diam. 133mm |
|
turns 36 |
|
Emissions testing |

|
Circular Helmholtz Coils |
|
DC - 2 kHz |
|
Diam.: 256mm |
|
Turns: 536 |

|
HS 3D-SENS50T1 3D DC magnetic field sensor head |
|---|
|
3D DC Magnetic Field Sensor Head |
|
Measuring range: typ. max. ± 50mT |
|
Use with HS 3D-Control |
|
Ideal to use to measure ambient magnetic field for DO-160 Section 15 |

|
Display and control for 3D DC Magnectic Field Sensor Head |
|
Measuring range: typ. max. ± 50mT or 120mT |
|
16 Hour battery life |

|
9 kHz - 30 MHz |
|
Loop Diameter 150 mm |
|
Type N (female) |

|
Handheld magnetic field meter |
|
150 kHz - 400 MHz |
|
Shown short Version |

|
Isotropic H-Field Antenna |
|
Rohde und Schwarz handheld spectrum analyser FSH or the TS-EMF System. |
|
9 kHz - 200 (300) MHz |
|
Lightweight low attenuation radome |
|
Outer diameter ca. 150 mm |

|
Loop Antenna System ( LAS ) |
|
3-dimensional large loop antenna |
|
diam. 2 m |
|
acc. EN 55015 / CISPR 15 |
|
Socket and Coaxial switch recommended |

|
Loop Antenna System ( LAS ) |
|
3-dimensional large loop antenna |
|
diam. 3 m |
|
acc. EN 55015 / CISPR 15 |

|
1 - 300 MHz |
|
diam. 50 mm |
|
1 Turn |
|
Transformer |

|
0.07 - 120 MHz |
|
diam. 100 mm |
|
1 Turn |
|
Transformer |

|
0.05 - 30 MHz |
|
diam. 250 mm |
|
1 Turn |
|
Transformer |

|
13.56 MHz 370 kHz Bandwidth |
|
diam. 250 mm |
|
2 Turn |
|
16 Watts |

|
0.009 - 400 MHz |
|
diam. 50 mm |
|
1 Turn |
|
Transformer |

|
Circular Transmitting Loop Antenna |
|
diam. 180 mm |
|
1 turn |

|
HFRA 5149 - 0.009 - 30 MHz Transmitting Tunable loop antenna |
|---|
|
The circular transmitting loop antenna |
|
9 kHz - 30 MHz |
|
diam. 500 mm |
|
including 50 Ohm 20 Watt termination |
|
N-connectors |

|
The circular transmitting loop antenna |
|
DC - 3 MHz |
|
diam. 250 mm |
|
BNC Connectors |

|
The circular transmitting loop antenna |
|
DC - 30 MHz |
|
diam. 180 mm |
|
BNC Connectors |

|
The circular transmitting loop antenna |
|
0.1 - 30 MHz |
|
diam. 100 mm |
|
Transformer to 50 Ohms |
|
BNC Connectors |

|
The circular transmitting loop antenna |
|
0.1 - 100(300) MHz |
|
diam. 50 mm |
|
Transformer to 50 Ohms |
|
BNC Connectors |

|
The circular transmitting loop antenna |
|
DC - 5 MHz |
|
diam. 50 mm |
|
turns 10 |
|
BNC Connectors |

|
HFRA 5157- DC - 30 MHz Transmitting loop antenna |
|---|
|
The circular transmitting loop antenna |
|
DC - 20 (30) MHz |
|
diam. 100 mm |
|
turns 2 |
|
BNC Connectors |

|
The circular transmitting loop antenna |
|
DC - 2 MHz |
|
diam. 180 mm |
|
turns 10 |
|
BNC Connectors |

|
The circular transmitting loop antenna |
|
DC - 400 kHz |
|
diam. 250 mm |
|
turns 28 |
|
BNC Connectors |

|
The circular transmitting loop antenna |
|
DC - 30 MHz |
|
diam. 100 mm |
|
turns 1 |
|
BNC Connectors |

|
DC - 10 MHz |
|
1-meter square |
|
turns 1 |
|
Immunity testing to IEC 61000-4-8, IEC 61000-4-9 and IEC 61000-4-10 |

|
DC - 10 MHz, 400A Cont. 600A 10min |
|
up to 1200A/m 5sec with MFPO 9760 |
|
1-meter square |
|
turns 1 |
|
Immunity testing to IEC 61000-4-8, IEC 61000-4-9 and IEC 61000-4-10 |

|
Current Transformer for IEC 61000-4-8 AC magnetic fields |
|
50 or 60 Hz Feed |
|
Produce 1000A/m short duration testing (pulse generator) |
|
up to 400A continuous |
|
Includes stand for separately sold FESP 5410-1 |

|
Magnetic Compass with better than 1deg Accuracy |
|
Magnetometer HS 3D-SENS50T1 Hall-Sensor |
|
Zero-Gauss Chamber |
|
Flexible Measuring tape, Non-Mitalic |
|
EPS Foam Support for Compass |
|
Transit Case for easy storage |