Maury MW - Amplified Noise Module - NC2000-4000 Series
- High-level noise modules mounted on a circuit board
- Modified BW, output power, and flatness specifications
The NC2000 Series amplified noise modules are an excellent choice for high-level noise modules mounted on a circuit board. The NC2000 Series modules are housed in 24, or14-pin dual-inline packages. The NC4000 series modules are housed in a 40-pin module that cover similar noise bands to the NC2000, but have higher crest factor, and 60 dB of TTL controlled attenuation. Modified BW, output power, and flatness specifications are available for these modules. Please consult Noisecom for availability, and appropriate package style.
|
Output |
Minimum Power Output |
Crest Factor |
Flatness |
|---|---|---|---|
|
White Gaussian noise |
25 dB ENR (-143 dBm/Hz) min |
5:1 |
+/-3dB |
More Product Information
- SOSA Aligned
- 3U VPX Form-Factor
- Reduced SWaP applications
- Ruggedization Level 200
- 11 Radial Clock Outputs
- OpenVPX Backplane support for 1000BASE-KX or 10GBASE-KR
- Optional Chip Scale Atomic Clock (CSAC) Holdover
- Optional Low Phase Noise (LPN) Analog output
- Optional secure GPS (M-code)
- Optional Timecode I/O
- Vector Network Analyzer Frequency Range from 10 MHz up to 3.2 GHz
- Spectrum Analyzer Frequency Range from 9 kHz up to 3.2 GHz
- -156 dBm/Hz Displayed Average Noise Level (Typ.)
- -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.)
- Total Amplitude Accuracy < 1.2 dB
- 1 Hz Minimum Resolution Bandwidth (RBW)
- All-Digital IF Technology
- Standard Preamplifier
- Distance to fault capability using VNA time domain analysis
- Up to 1.5 GHz Tracking Generator Kit
- Built-in Advanced Measurement capability (CHP, ACPR, OBW, CNR, TOI, etc)
- 10.1 lnch WVGA (1024 x 600) Display
- Complete bias circuits
- Requires no external components
- Optimizations available for frequency range and output levels
The NC520 low voltage (surface mount) noise module is an economic solution for built-in test requirements. It contains complete bias circuits and require no external components.
The surface mount package is suitable for mounting on microstrip. The modules produce extremely flat output power versus frequency characteristic that is insensitive to temperature and voltage variations.
Typical applications for the NC520 module includes built-in test equipment (bite), signal strength meters for cellular, pcs, catv, calibrators, spectrum analyzers, radar warning receivers (rwr), and dither A/D quantization error. Maury can optimize frequency range and output levels for specific applications.
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Coaxial air lines are air-dielectric transmission lines with highly accurate dimensions that can be used as fundamental impedance standards in measurement and calibration applications, and may also be used to establish reference positions for measurements.
Bead supported air lines offer greater convenience and easier connections (the center conductor is automatically aligned by the dielectric bead for easy connection); beadless air lines offer better impedance and electrical length accuracies, as well as lower VSWR (the center conductor floats free in the air line body, and the male connector nut is retractable to facilitate insertion of the center conductor contact before the thread- on connection tightened.
-
Defect pixel correction (on/off)
-
Fixed pattern noise correction (on/off)
-
Region of interest (ROI)
-
Gain (manual control, 0 to 20 dB)
-
Exposure (manual control, 44.2 µs to 1.4 s)
-
Gamma correction
-
Reverse X
-
DeviceLinkThroughputLimit (easy bandwidth control)
-
Sync out modes: Waiting for a trigger, exposing, readout, imaging
-
Storable user sets
- Coaxial and triaxial measurements up to 10,000 V
- High-quality construction with low-noise electrical performance
- Replaceable probe tips in a variety of tip sizes
- Temperature range of of -60°C to 300°C
- Triaxial measurement ensures a much better understanding of device leakage in the off state
- Highly reliable, stable and repeatable measurements
- Integrally designed as part of a complete measurement solution
- Ultra-low distortion signal path
- Standard connectors SMA female
- 7” touch screen display
- Dimensions: 17.22 in. wide x 6.30 in. including feet, high x 19.5 in. deep
- Fold-down feet for bench top use
- Power 115 VAC, 60 Hz
- Operating Temperature: -10° to +65°C
- Differential inputs and outputs
- Multiple differential inputs and outputs
Linea SWIR features a cutting-edge InGaAs sensor in a compact package that is suitable for a wide variety of applications. With exceptional responsivity and low noise, this camera allows customers to see their products like never before. Linea SWIR is available as a 1k resolution camera with highly responsive 12.5 µm pixels, or a 512 resolution camera with larger 25 µm pixels.
-
Auto gain (manual gain control: 0 to 22 dB)
-
Auto exposure (manual exposure control: 100 µs to 1 s, 1 µs increments)
-
Binning (horizontal and vertical) (sum)
-
Decimation X/Y
-
Enhanced Defect Pixel Correction (DPC)
-
Fixed Pattern Noise Correction (FPNC)
-
Gamma correction
-
Three look-up tables (LUTs)
-
Region of interest (ROI)
-
EF lens control (order option -18)
-
Event channel
-
Image chunk data
-
IEEE 1588 Precision Time Protocol (PTP)
-
RS232
-
Storable user sets
-
StreamBytesPerSecond (bandwidth control)
-
Stream hold
-
Sync out modes: Trigger ready, input, exposing, readout, imaging, strobe, GPO
-
Temperature monitoring (main board and sensor board)
-
Trigger over Ethernet (ToE) Action Commands
Maury Microwave
Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.