- Redundant design with multiple signal paths built in for high-availability.
- 12 expansion slots in the 2U version and 5 expansion slots in the 1U variant.
- Industry-first GPS integrity checking
- Unique optical crosslink architecture for either Master-Slave hierarchical setups or Master-Master crosschecking and failover
- 2U version is operated by an intuitive touch-screen interface, a first for any master clock system.
- All components are hot-swappable and are dual redundant.
- The Output Signal modules are hot-swappable from the front and minimize the need to disconnect cables.
- High performance GPS disciplined Time/Frequency standard
- Ethernet Interface for management and control
- Network Time Protocol (NTP)
- Multiple 1PPS outputs with individual delay compensation
- Multiple Low Phase Noise 10MHz outputs with software programmable level
- Time Code outputs including Have Quick, IRIG A, IRIG B, IRIG E, IRIG G
- Sync to GPS or to Have Quick/1PPS per ICD-GPS-060
- Choice of internal disciplined OCXO or Rubidium Oscillator
- Accurate & reliable time data from a trusted source
- Remote configuration and status via web browser, remote monitoring with SNMP
- Synchronization between users – eradicates discrepancies
- System time stamping, such as e-commerce transactions, e-mail sent & received, is highly accurate
- Automatic systems procedures such as backups occur at the correct time and in the correct order
- Additional time signal outputs can feed to other systems
- Multiple time source fall back and priority configuration can ensure high synchronization availability
- Various oscillator choices allow for long holdover to maintain time accuracy when synchronization signals are absent
- Accurate & reliable time data from a trusted source
- Control over configuration via web browser
- Synchronization between users – eradicates discrepancies
- System time stamping (e.g. for e-commerce transactions, e-mail sent & receive, etc) is highly accurate
- Automatic systems procedures, such as backups, occur at the correct time and in the correct order
- Compact size and low cost
- Uses Network Time Protocol to synchronize computers and other devices
- Programmable serial message compatible with almost any time display
- Browser based user interface for easy setup
- GPS synchronized
- LED colons indicate GPS lock status
- Allan deviation σ(τ) = 2.7×10-11 T-1/2 for long life version and σ(τ) = 8.5×10-12 T-1/2 for high performance version
- Front or Rear access connectors
- 3U high (133mm / 5.24”) — less than 200mm depth, compatible with ETSI and 19” standards
- Accuracy better than ±1×10-12 / ±5×10-13 for high performance version
- 10 MHz low noise direct output
- Programmable 1 / 5 / 10 MHz TTL output
- 10 years warranty on cesium tube (3 years for high performance version)
- Redundant DC power supply inputs
- Remote control and monitoring via RS232 (fully manageable locally and remotely using SyncView Plus management system.
Brandywine - PC104-Plus SyncClock32 Advanced PC/104 timing board that conforms to the PC/104Plus 2.0
- IRIG’s A and B and NASA 36 time code inputs
- +3.3V or +5V signaling
- 1PPS Sync input
- External Event (Time Tag) input
- Three programmable pulse rate outputs
- Match Time output
- Industrial Temperature Range option
- Optional on-board GPS option
- Optional HaveQuick input/output
- Optional IRIG B time code output
- 3/4 length board (1/2 size available w/o GPS input)
- Optional Have Quick synchronization input
- IRIG’s A and B and NASA 36 time code inputs
- 1PPS sync input
- IRIG B output option
- 1PPS and time code inputs are redundant
- Single-slot including GPS option
- Zero latency time reads
- External Event input (optional eight or sixteen inputs)
- Match Time output
- Programmable Heartbeat rate