Meatest - M525 Programmable Capacitance Decade
Programmable capacitance decade with continuous range from 100 pF to 100 uF. Based on M6xx Real-Resistance decade series for great user comfort.
- 0.25% accuracy, maximum voltage 50 V
- Grounded / floating operation
- User defined conversion tables
M525 Programmable Capacitance Decade is designed specifically for calibration of capacitance ranges of multimeters and LCR meters. Due to its versatility it can be used in cal labs, repair centers and in production lines, where remote control of capacitance is needed. The M525 contains relays with high current capability and capacitors with polypropylen dielectricum for best performance.
Languages: English, German, Spanish, French, Russian, Czech
Time-proven design
Based on M6xx series, this programmable decade comes with similar benefits - large LCD showing relevant parameters including total accuracy, automatically compensated parasitic capacitances, easy recalibration procedure and extensive remote control connectivity via RS232, IEEE488, USB and Ethernet.
|
Capacitance |
100 pF - 100 uF ± 0.25% / year |
|---|
More Product Information
- Network Enabled Frequency Distribution Amplifier
- Dual Frequency Inputs with Auto Failover
- Low Phase Noise Reference Frequency Outputs
- Programmable per channel amplitude
- 1U 19” rack mount
- Redundant Hot Swappable Power Supplies
Single phase electric power/energy calibrator for calibration and testing of power meters and power transducers. Terminals 2 and 3 are inactive.
- 0.01° phase shift accuracy
- 15 - 1000 Hz output
- Built-in multimeter for transducer calibration
- Floating current output for 3-wire power meters
- Voltage from Current function
-
High SNR mode (up to 24 dB better signal-to-noise ratio)
-
Low-Noise Binning Mode
-
Smear reduction
-
Shading correction
-
Area of interest (AOI), separate AOI for auto features
-
Binning
-
Decimation
-
Auto gain (manual gain control: 0 to 32 dB)
-
Auto exposure (39 µs to 67 s)
-
Auto white balance
-
Look-up table (LUT)
-
Hue, saturation, color correction
-
Reverse X
-
Deferred image transport
-
Trigger programmable, level, single, bulk, programmable delay
-
Sequence mode (changes the camera settings on the fly)
-
SIS (secure image signature, time stamp for trigger, frame count)
-
Storable user sets
- 3U or 6U CPCI form factor
- Optional Have Quick synchronization input
- IRIG’s A and B and NASA 36 time code inputs
- 1PPS sync input
- IRIG B output
- 1PPS and time code inputs are redundant
- Single-slot including GPS option
- Zero latency time reads, microseconds through years
- External Event input (optional eight and sixteen inputs)
- Match Time output
- Programmable Heartbeat rate
- Many additional options
- 6U, Single Width VME
- Time Code Inputs
- Time Code Output
- 1PPS Pulse Rate Output/Interrupt
- Frequency Outputs (1, 5, 10 MHz)
- External Event Capture/Interrupt
- Programmable Periodic Output/Interrupt
- Programmable Time Strobe Output/Interrupt
- Allan deviation σ(τ) = 2.7×10-11 T-1/2 for long life version and σ(τ) = 8.5×10-12 T-1/2 for high performance version
- Front or Rear access connectors
- 3U high (133mm / 5.24”) — less than 200mm depth, compatible with ETSI and 19” standards
- Accuracy better than ±1×10-12 / ±5×10-13 for high performance version
- 10 MHz low noise direct output
- Programmable 1 / 5 / 10 MHz TTL output
- 10 years warranty on cesium tube (3 years for high performance version)
- Redundant DC power supply inputs
- Remote control and monitoring via RS232 (fully manageable locally and remotely using SyncView Plus management system.
Resistance decade box with 100 mΩ - 22 MΩ range and 5W load capacity. Best resolution 1 μΩ, RTD temperature sensor simulation feature.
- Real resistors switched by relays
- 14 decade range, resolution from 1 μΩ
- Custom units and time sequences
- No residual resistance
- 5 W load capacity
- Six different languages
Resistance decade box designed for RTD and other resistance-based sensors' simulation. 0.01°C accuracy and 0.001°C resolution.
- Real resistors switched by relays
- Custom temperature scales
- No residual resistance
- 0.01°C accuracy
- Six different languages
-
High SNR mode (up to 24 dB better signal-to-noise ratio)
-
Low-noise binning mode
-
Smear reduction
-
Shading correction
-
Defect pixel correction
-
Area of interest (AOI), separate AOI for auto features
-
Binning
-
Decimation
-
Auto gain (manual gain control: 0 to 24 dB)
-
Auto exposure (129 µs to 67 s)
-
Auto white balance
-
Look-up table (LUT)
-
Hue, saturation, color correction
-
Reverse X
-
Deferred image transport
-
Trigger programmable, level, single, bulk, programmable delay
-
Sequence mode (changes the camera settings on the fly)
-
SIS (secure image signature, time stamp for trigger, frame count)
-
Storable user sets
Meatest
We develop and manufacture electrical calibration instruments for calibration laboratories and testing facilities in electronics, engineering, utility, aeronautics and telecommunications sectors. Designed for automated calibrations our instruments bring effective solutions to customers like NPL, Samsung, Siemens and Volkswagen.
Contact Details
Meatest, spol. s r.o. Headquarters
Železná 509/3, Czech Republic - 619 00 BRNO
GPS: 49°10'13.93"N,16°36'53.2"E
Phone: 420-543-250-886
Fax: 420-543-250-890
Email: meatest@meatest.cz