Meatest - M133C 1F Power & Energy Calibrator
-
Power quality and energy functions
-
0.01° phase shift accuracy
-
15 - 1000 Hz output
-
Built-in multimeter for transducer calibration
-
Floating current output for 3-wire power meters
-
Voltage from Current function
Single phase electric power/energy calibrator with power quality functions for calibration and testing of grid measuring appliance like power meters, power transducers or power quality analysers. Terminals 2 and 3 are inactive.
M133C is electric AC/DC power and energy calibrator for calibration of power meters, power transducers, power quality analysers and generally all kinds of power measuring devices. AC voltage, current, power and energy functions have calibrated phase shift in frequency range from 15 Hz to 1 kHz with resolution as good as 0.001 Hz. Built-in 5½ process multimeter for transducer calibration is standard part of every M133C calibrator.
Languages: English, Chinese (simplified)
Power quality functions
Four different distortion functions are available in M133C calibrator: Harmonic distortion with up to 63 harmonic products, interharmonic distortion up to 5000 Hz, amplitude modulation using symetrical sine or square wave envelope and finally dip/swell amplitude modulation using custom square wave envelope. Modulation frequency can be set in range from 0.001 Hz to 50 Hz, maximum modulation depth is 30 %.
Calibration versatility
M133C is more than just a sophisticated power source. Using built-in process multimeter, both transducer inputs and outputs can be handled by the M133C at the same time so you can calibrate it more easily, using no other calibration equipment. Floating current output can be connected directly with voltage output to allow for 3-wire power meter calibration. One calibrator, many applications - saving your time, space and costs.
DC voltage |
1 - 280 V ± 150 ppm / year |
AC voltage |
1 - 600 V, 15 - 1000 Hz ± 120 ppm / year |
DC current |
5 mA - 30 A (1500 A with 140-50 Current Coil) ± 175 ppm / year |
AC current |
5 mA - 30 A, 15 - 1000 Hz (1500 A with 140-50 Current Coil) ± 175 ppm / year |
DC Power & Energy |
5 mW - 8.4 kW (420 kW with 140-50 Current Coil) ± 380 ppm / year |
AC Power & Energy |
5 mW - 18 kW, 15 - 1000 Hz (900 kW with 140-50 Current Coil) 0.01° phase shift accuracy, power factor -1 to +1 Harmonic, interharmonic, modulation/flicker, dip/swell distrortion functions ± 370 ppm / year |
Process Multimeter
DC voltage |
0 - 12 V ± 100 ppm / year |
DC current |
0 - 25 mA ± 100 ppm / year |
Frequency |
1 Hz - 15 kHz ± 50 ppm / year |