Dualos - Fittings - NEO 601F Series
NEO X01 3000 PSI Adapters
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
D |
|
NEO 601F-P-04 |
4, 12 |
JIC-37 Degree |
4 |
0.4375-20 UNJF Class 3B |
2.13 |
0.48 |
- |
|
NEO 601F-P-05 |
12 |
JIC-37 Degree |
5 |
0.5000-20 UNJF Class 3B |
2.13 |
0.48 |
- |
| NEO 601F-P-06 |
6, 12 |
JIC-37 Degree |
6 |
0.5625-18 UNJF Class 3B |
2.18 |
0.49 |
- |
|
NEO 601F-P-08 |
8, 12 |
JIC-37 Degree |
8 |
0.7500-16 UNJF Class 3B |
2.30 |
0.56 |
- |
| NEO 601F-P-10 |
10, 12 |
JIC-37 Degree |
10 |
0.8750-14 UNJF Class 3B |
2.44 |
0.66 |
- |
|
NEO 601F-P-12 |
12 |
JIC-37 Degree |
12 |
1.0625-12 UNJ Class 3B |
2.52 |
0.70 |
- |
|
NEO 601F-P-16 |
12 |
JIC-37 Degree |
16 |
1.3125-12 UNJ Class 3B |
2.74 |
0.79 |
- |
|
NEO 601F-P-20 |
12 |
JIC-37 Degree |
20 |
1.6250-12 UNJ Class 3B |
2.87 |
0.98 |
- |
*Approximate Dimensions [inches]
More Product Information
All caps ship with Skydrol (BMS3-11) Compatible O-ring Seal. Parts in compliance with all SMOT document requirements.
- Device and operation are according to the standard IEC 60811-506 (IEC 60811-1-4) point 8.5
- Case set offers all required weights for the test
- Easy operation
- Very robust and solid construction
- Steel impact piece included
- Up to 3 Samples can be tested simultaneously
- Device suitable for positioning in a cold chamber - Product No.: 402.0020.02
With their domed shape, LUMIMAX® LED dome lights generate a diffused light that falls on the test object from all directions, achieving completely shadow-free illumination.
Typical applications are the inspection of reflective or mirroring materials. With a LED dome light, even complex or curved surfaces can be illuminated homogeneously.
LED dome lights are extremely well suited for standard-compliant reading and verification of two-dimensional codes.
-
NEO 941 parts are AS5836 compatible (Clam Shell Clamps not Included)
-
NEO 942 parts are AS1653 compatible (Clam Shell Clamps not Included)
- Robust and compact design, easy to handle
- Fast, reliable and highly accurate measuring process
- Integrated hardware and software, touch monitor for intuitive operationReliable, high-precision clamping of the test specimen (including conical tools / conical wire guides)
- The highly precise alignment of camera and test object chuck both enable a highly accurate measurement
- No extraneous light influences thanks to measuring behind closed sliding door
Dualos