Amplifier Research - RF Conducted Immunity Testing to IEC, Military & Automotive Standards
If you are tired of mixing and matching various components, try AR’s complete line of RF Conducted Immunity Test Systems. We now make one fully configured and standalone CI System from 4 kHz to 400 MHz with output powers designed to meet the latest commercial, custom, and military standards. In addition, AR provides configurable systems meeting your specific requirements of increased power and frequency range. Each CI System has the built-in flexibility to conduct standard and customized tests, using our user-friendly software (emcware®) that can generate reports directly into Microsoft® Word or Excel.
CDN Testing to 250 MHz
25 W, 10 kHz – 250 MHz
Complete Testing Solutions to the following standards: EN/IEC 61000-4-6, IEC 60601-1-2, EN 50130-4, EN 61000-6-1/2, EN 55024, ISO 11452-4, and other automotive standards.
Signal Generator Specifications |
|
---|---|
Frequency Range/Resolution |
9 kHz to 1.5 GHz / 0.01 Hz |
Power Range/Resolution |
-110 to +13 dBm / 0.01 dB |
Modulation |
AM, FM, Phase, Int Pulse, Ext Pulse |
Spectrum Analyzer Specifications |
|
---|---|
Frequency Range/Resolution |
9 kHz to 1.5 GHz / 1 Hz |
RF Power CW (max) Atten = 30 dB |
20 dBm |
Resolution BW |
10 Hz to 1 MHz |
Video BW |
1 Hz to 3 MHz |
Amplitude Measurement Range |
-110 dBm to +20 dBm in 1 dB steps |
Preamplifier Gain |
20 dB (nom) |
Sweep Time, span> 100 Hz |
10 msec to 1,500 sec |
RF Solid State Amplifier Specifications |
|
---|---|
Frequency Range |
10 kHz to 250 MHz |
Power Rating At 1 dB compression the power is 20 W min. |
25 W min. |
Harmonic Distortion |
-20 dBc at 75 W |
Mismatch Tolerance |
100% of rated power without fold back. Will operate without damage or oscillation with any magnitude of source and load impedance. |
Gain |
50 dB min. |
Connections |
|
---|---|
RF Out |
Type N (front) |
Monitor Port In |
Type N (front) |
Signal Generator Out |
Type N (rear) |
RF Amp In/Out |
Type N (rear) |
Directional Coupler In |
Type N (rear) |
Pulse In |
BNC (rear) |
Communication |
USB B (rear) |
Directional Coupler Fwd Out |
Type SMA (rear) |
Directional Coupler Fwd In |
Type SMA (rear) |
Directional Coupler Rev Out |
Type SMA (rear) |
Directional Coupler Rev In |
Type SMA (rear) |
General |
|
---|---|
Power |
115/230 VAC, 50/60 Hz, single phase 16 A |
Breaker |
2 pole, 20 A |
Cooling |
Active cooling, air ventilation |
Environmental Conditions |
10°C–40°C (50°F–104°F) |
Dimensions |
50.3 x 53.3 x 55.1 cm (19.8 x 21.0 x 21.7 in.) |
Weight |
49.9 kg (110 lb.) |
PC Requirements |
|
---|---|
Computer |
Intel Pentium 4, AMD Athlon 64 or better processor |
Operating System |
Windows, 7, 8, or 10 |
RAM |
2 GB Minimum |
Screen Resolution |
1024 x 768 |
Ports |
2 available USB 2.0 ports |
Software Requirements |
Microsoft Word/Excel 2007 or newer |
BCI, EM or TWC Testing to 1 GHz
250 W, 100 kHz – 1000 MHz
Complete Testing Solutions to the following standards: EN/IEC 61000-4-6, IEC 60601-1-2, EN 50130-4, EN 61000-6-1/2, ISO 11452-4, and other automotive standards.
Internal Test Specifications |
---|
IEC/EN 60601-1-2, IEC/EN 50130-4, IEC/EN 61326, IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-4-6, ISO 11452-4, EMC-CS-2009, GM GMW3097, BMW GS95002, Chrysler DC-11224, Renault 36-00-808, and other automotive standards. |
Signal Generator Specifications |
|
---|---|
Frequency Range/Resolution |
9 kHz to 1.5 GHz / 0.01 Hz |
Power Range/Resolution |
-110 to +13 dBm / 0.01 dB |
Modulation |
AM, FM, Phase, Int Pulse, Ext Pulse |
Spectrum Analyzer Specifications |
|
---|---|
Frequency Range/Resolution |
9 kHz to 1.5 GHz / 1 Hz RF Power CW (max) |
Atten = 30 dB |
20 dBm |
Resolution BW |
10 Hz to 1 MHz |
Video BW |
1 Hz to 3 MHz |
Amplitude Measurement Range |
-110 dBm to +20 dBm in 1 dB steps |
Preamplifier Gain |
20 dB (nom) |
Sweep Time, span> 100 Hz |
10 msec to 1,500 sec |
RF Solid State Amplifier Specifications |
|
---|---|
Frequency Range |
100 kHz to 1,000 MHz |
At 1 dB compression the power is 175 W min. |
|
Power Rating |
250 W min. |
At 1 dB compression the power is 175 W min. |
|
Harmonic Distortion |
-20 dBc at rated power |
Mismatch Tolerance 100% of rated power without fold back. Will operate without damage or oscillation with any magnitude of source and load impedance. |
|
Gain |
54 dB min. |
Connections |
|
RF Out |
Type N (front) |
Monitor Port In |
Type N (front) |
Signal Generator Out |
Type N (rear) |
Directional Coupler In |
Type N (rear) |
RF Amp In/Out |
Type N (rear) |
Communication |
USB (rear) |
Directional Coupler Fwd Out |
Type SMA (rear) |
Directional Coupler Fwd In |
Type SMA (rear) |
Directional Coupler Rev Out |
Type SMA (rear) |
Directional Coupler Rev In |
Type SMA (rear) |
General |
|
---|---|
Power |
115/230 VAC, 50/60 Hz, single phase 16 A |
Breaker |
2 pole, 20 A |
Cooling |
Active cooling, air ventilation |
Environmental Conditions |
10°C–40°C (50°F–104°F) |
Dimensions |
128.9 x 56.1 x 91.4 cm (52.5 x 22.1 x 36 in.) |
Weight |
72.6 kg (160 lb.) |
PC Requirements |
|
---|---|
Computer |
Intel Pentium 4, AMD Athlon 64 or better processor |
Operating System |
Windows, 7, 8, or 10 |
RAM |
2 GB Minimum |
Screen Resolution |
1024 x 768 |
Ports |
2 available USB 2.0 ports |
Software Requirements |
Microsoft Word/Excel 2007 or newer |
BCI, EM or TWC Testing to 3 GHz
25 W, 10 kHz – 3 GHz
Complete Testing Solutions to perform Automotive Conducted Immunity testing over the frequency range of 100 kHz–3 GHz at test levels of up to 200 mA.
Internal Test Specifications* |
---|
MIL-STD-461F and G, CS114, DO160D Section 20 BCI testing, DO160E Section 20 BCI testing, IEC/EN 60601-1-2, IEC 61000-4-6 procedure and levels, IEC/EN 50130-4, IEC/EN 61326, IEC/EN 61000-6-1, IEC/EN 61000-6-2, CISPR 24/EN 55024, ISO 11452-4, GMW 3097, ES-XW7T-1A278-AC, DC-11224, BMW GS95002, and other automotive standards. |
Signal Generator Specifications |
|
---|---|
Frequency Range |
9 kHz to 3 GHz |
Amplitude Resolution |
0.01 dB |
Modulation |
AM, PM, Pulse Modulation |
Power Range |
-144 to +26 dBm |
Spectrum Analyzer |
|
---|---|
Frequency Range |
9 kHz to 3 GHz |
Frequency Resolution |
1 Hz |
Detectors |
Positive and negative peak, sample, normal, RMS |
Amplitude Accuracy |
± 0.5 dB, typical |
RF Solid State Amplifier Specifications |
|
---|---|
Frequency Range |
9 kHz to 400 MHz |
Power Rating At 1 dB compression the power is 75 W min. |
100 W min. |
Harmonic Distortion |
-20 dBc at 75 W |
Mismatch Tolerance 100% of rated power without fold back. Will operate without damage or oscillation with any magnitude of source and load impedance. |
|
Gain |
50 dB min. |
Connections |
|
---|---|
RF Out |
Type N Male (front) |
Monitor Port In |
Type N Male (front) |
Communication |
GPIB (rear) |
General |
|
Power |
115/230 VAC, 50/60 Hz, single phase 16 A |
Breaker |
2 pole, 20 A |
Cooling |
Active air cooling, air ventilation |
Environmental Conditions |
10°C to 40°C (50°F–104°F) |
PC Requirements |
|
---|---|
Computer |
Minimum Intel Pentium 4/AMD Athlon 64 or better processor |
Operating System |
Windows, 7, 8, or 10 |
RAM |
2 GB Minimum |
Free Hard Drive Space |
2 GB |
Screen Resolution |
1024 x 768 |
Ports |
2 available USB 2.0 ports |
Software Requirements |
Microsoft Word/Excel 2007 or newer |
*Specifications can be met using AR-specified external accessories (injection probes, monitor probes, calibration fixtures, CDNs, attenuators, etc.). All conducted immunity systems can be configured to cover 4 kHz to 3 GHz.
Model Number |
Description |
---|---|
RF Conducted Immunity System contains a signal generator, spectrum analyzer, 100 W nominal AR amplifier, a 10 kHz – 400 MHz directional coupler and emcware® control software |