Maury MW - VNA Verification Kit Series
- S-parameters comparison of user-characterized and factory-characterized verification standards
- S-parameters comparison of user-characterized and factory-characterized verification standards with measurement uncertainty boundaries
- Includes beaded airline, mismatch airline, offset shorts and fixed loads
Characterized Device (CD) Calibration Verification Kits are designed for 1-port and 2-port VNA calibration validation for well-matched and mismatched DUTs. Each kit comes with individually characterized verification standards and is used for calibration validation by comparing the S-parameters of the appropriate verification standard measured by the user and the S-parameters measured at the factory. When combined with Insight™, users will be able to use overlapping uncertainty boundaries to validate a VNA calibration with increased confidence. Verification kits are available with Type N, 7mm, 3.5mm, 2.92mm and 2.4mm connectors.
|
Frequency Range |
Measurement Range |
RF Channel Video Bandwidth |
|
5 MHz to 50GHz |
1- and 2-Port |
Included |
More Product Information
- Flexible bench configuration empowers users to easily set up instruments and DUTs to match any measurement workflow.
- Automated, multi-instrument calibration workflows empower users to achieve high accuracy results across diverse setups with minimal user intervention.
- Built-in system calibration verification instills confidence in measurement accuracy before data collection begins.
- Comprehensive small-signal, large-signal, and pulsed testing captures real-world device behavior for reliable design and modeling.
- Powerful visualization and analytics suite empowers users to quickly interpret results, extract models, and drive faster design decisions.
- Excellent temperature and voltage stability
- Units for noise figure meters feature 15.5-dB ± 0.75 dB ENR output
- High-output units for radar and satellite communications system testing feature output between 26 and 35 dB ± 1 dB ENR
The NC3000 Series calibrated coaxial AWGN sources are well suited for receiver testing, noise figure measurements, or applications that require broadband noise and fast switching times. Several models include output isolators, and voltage regulators that provide excellent stability over varying temperature and voltage ranges. The NC3000 Series includes the NC3100 units with 15 dB ENR output for noise-figure meters, and the NC3200 Series high-output noise sources with outputs between 26 and 35 dB ENR for radar and satellite communications system testing.
- 1-port VNA with frequency options from 150 kHz to 6 GHz
- External PC control enables control of multiple ShockLine MS46121B devices in parallel for excellent multisite throughput
- Very compact package allows for direct connection to the DUT
- Scalar transmission measurements in a (1-to-1) or (1-to-n) configuration
- No on-board data storage eliminates the need for data purging in secure applications
- Standard bandpass time domain with time gating enables easier and faster fault identification
- A common GUI interface within the ShockLine family reduces switching costs between models
- Guaranteed performance to 43.5 GHz with Extended K™ ports
- High output power allows measurement of high attenuation devices
- Wide dynamic range enables measurement of very low reflection artifacts
- Excellent corrected directivity minimizes measurement uncertainty
- SmartCal™ auto calibration unit reduces calibration and setup time
- Time domain with time gating option grants easier and faster fault identification
- Modern LAN interface for remote control is faster than GPIB
- A common GUI and SCPI interface within the ShockLine family
- Bias tee option simplifies test setups where the DUT needs DC biasing
- Universal Fixture Extraction (UFX) software option provides advanced de-embedding tools for test fixture extraction
- E-Band VNA
- Extended frequency range covering E-band and major parts of V band
- Fully assembled test system eliminates setup errors and increases reliability
- Tethered modules connect directly to the DUT increasing measurement stability
- Leverage dual-camera single-laser design to deliver exceptionally high 3D reproduction fidelity
- Scan scenes quickly with profiling rates of up to 11,000 per second
- Gain from unique embedded algorithms to generate consistent profiles, depth maps, or point clouds
- Benefit from truly standard GigE Vision® interface to work directly with Zebra Imaging and third-party vision software
- Simplify cabling with Power-over-Ethernet (PoE) support
- Deploy confidently in tough industrial settings thanks to a solid IP67-rated2 aluminum housing and M12 connectors
- Benefit from several fastening points to facilitate fixing one or more sensors to gantries and robots
- Streamline sensor setup and verification via the Aurora Capture Works utility for Windows® and Linux®
- Speed: Calibration is faster since there is no need to manually connect and disconnect standards.
- Accuracy: Eliminates errors caused by manual handling, such as connector inconsistencies and improper torquing.
- Ease of Use: Minimal user interaction is required, making calibration simpler and more accessible.
- Reliability: Reduces wear and tear on VNA ports and connectors, prolonging their lifespan.
- Consistency: Provides repeatable results across multiple calibration sessions and users.
- Vector Network Analyzer Frequency Range from 10 MHz up to 3.2 GHz
- Spectrum Analyzer Frequency Range from 9 kHz up to 3.2 GHz
- -156 dBm/Hz Displayed Average Noise Level (Typ.)
- -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.)
- Total Amplitude Accuracy < 1.2 dB
- 1 Hz Minimum Resolution Bandwidth (RBW)
- All-Digital IF Technology
- Standard Preamplifier
- Distance to fault capability using VNA time domain analysis
- Up to 1.5 GHz Tracking Generator Kit
- Built-in Advanced Measurement capability (CHP, ACPR, OBW, CNR, TOI, etc)
- 10.1 lnch WVGA (1024 x 600) Display
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Precision standard mismatches are fixed coaxial terminations, which are used to introduce a known VSWR into a 50 ohm transmission system. These mismatches are extremely useful in a wide variety of applications and are quick and easy to use. They can be used to calibrate swept reflectometers, verify network analyzer calibration, establish impedance references in TDR measurements.
- Custom electrical testing available upon request
- Wide package variety with custom configurations
- NC100 & 200 series for audio and RF applications
- NC300 & 400 series for microwave application
Noise diodes are the fundamental building blocks for analog noise systems. They are categorized for performance characteristics that enhance their broadband noise output and flat spectral response. All Maury noise diodes can deliver symmetrical white Gaussian noise and flat output power versus frequency*.
* Flatness and output power are dependent upon peripheral circuit characteristics
Maury Microwave
Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.