Maury MW - VNA Verification Kit Series
- S-parameters comparison of user-characterized and factory-characterized verification standards
- S-parameters comparison of user-characterized and factory-characterized verification standards with measurement uncertainty boundaries
- Includes beaded airline, mismatch airline, offset shorts and fixed loads
Characterized Device (CD) Calibration Verification Kits are designed for 1-port and 2-port VNA calibration validation for well-matched and mismatched DUTs. Each kit comes with individually characterized verification standards and is used for calibration validation by comparing the S-parameters of the appropriate verification standard measured by the user and the S-parameters measured at the factory. When combined with Insight™, users will be able to use overlapping uncertainty boundaries to validate a VNA calibration with increased confidence. Verification kits are available with Type N, 7mm, 3.5mm, 2.92mm and 2.4mm connectors.
|
Frequency Range |
Measurement Range |
RF Channel Video Bandwidth |
|
5 MHz to 50GHz |
1- and 2-Port |
Included |
More Product Information
- Excellent temperature and voltage stability
- Units for noise figure meters feature 15.5-dB ± 0.75 dB ENR output
- High-output units for radar and satellite communications system testing feature output between 26 and 35 dB ± 1 dB ENR
The NC3000 Series calibrated coaxial AWGN sources are well suited for receiver testing, noise figure measurements, or applications that require broadband noise and fast switching times. Several models include output isolators, and voltage regulators that provide excellent stability over varying temperature and voltage ranges. The NC3000 Series includes the NC3100 units with 15 dB ENR output for noise-figure meters, and the NC3200 Series high-output noise sources with outputs between 26 and 35 dB ENR for radar and satellite communications system testing.
- C/N carrier to noise ratio
- C/I carrier to interferer ration
- C/No carrier to noise density ratio
- Eb/No bit energy to noise density ratio
- Custom configurations
- 6.25″ color TFT touch screen
- Accuracy of 0.2 dB RSS
- Bit Rates from 1 bps to 1 Gbs
- Variable Output Power from -55 dBm to +5 dBm
- Complete bias circuits
- Requires no external components
- Extremely flat output power versus frequency characteristics
The NC500 (through-hole) and NC500SM (surface mount) Series noise modules are an economical solution for built-in test requirements. They contain complete bias circuits and require no external components. Some models contain additional gain stages for high power ENR output (51 dB). The surface mount package is suitable for mounting on micro strip. The modules have extremely flat output power versus frequency characteristics that are insensitive to temperature and voltage variations.
- Broadband coverage
- Extremely good temperature stability
- Superior voltage stability
- Noise figure meter-compatible
The NC346 Series is designed for precision noise figure measurement applications. Each module’s low VSWR reduces multiple reflections and significantly increases the measurement accuracy for most noise figure test configurations.
- 6 GHz, 8 GHz, 18 GHz and 40 GHz RF Power Sensors
- Up to 195 MHz video bandwidth with 3 ns rise time
- Real-Time Power ProcessingTM technology with zero measurement dead time
- 100,000 measurements per second
- Power Analyzer Suite advanced measurement and analysis software
- Crest factor, CCDF and statistical measurements
- 10 GS/s effective sample rate
- 100 MS/s continuous sample rate
- Synchronized multi-channel measurements
- Directly compatible with most commercial VNA’s
- Available as polynomial and characterized device kits
- Measure S-Parameters with uncertainty when used in conjunction with Maury’s Insight software platform
Maury offers coaxial and waveguide VNA calibration kits.
Coaxial calibration kits are offered in Polynomial SOLT, Characterized Device (CD) SOLT, and TRL, depending on the connector series. Where available, CD kits improve calibration accuracy when compared to SOLT kits based on polynomial definitions as each calibration kit is provided with individually characterized short, open and fixed load standards, whose S-parameters can be loaded into commercial VNAs directly or when used with Maury’s Insight™ software platform. When combined with Insight™, users will be able to quantify the uncertainty contribution of their calibration kit to their overall measurements. CD cal kits result in TRL-like accuracy with fixed-load SOLT ease-of-use.
- 1-port VNA with frequency options from 1 MHz to 8 GHz / 20 GHz / 43.5 GHz
- Guaranteed performance to 43.5 GHz with Extended-KTM ports
- PC control takes advantage of external computer processing power and functionality
- Small and lightweight package enables direct connection to the DUT
- No on-board data storage eliminates the need for data purging in secure applications
- All ShockLine VNAs share common software supporting GUI and program compatibility
- Time domain with time gating option enables easier and faster fault identification
- Simultaneous Sweep enabling users to operate multiple (up to four) MS46131A VNAs concurrently in independent software instances, unlocking true parallel measurement execution
- 4 kHz to 6 GHz and 10 MHz to 6, 18, and 40 GHz power sensors
- -60 dBm to +20 dBm dynamic range
- Pulse, Average, CW and Modulation modes
- True average measurements with essentially no modulation bandwidth limitations
- Real-Time Power Processing™ technology for virtually no gaps in signal acquisition and zero measurement latency
- 100,000 measurements per second
- Synchronized multi-channel measurements
- Suite of advanced measurement and analysis software
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Fixed flush and fixed offset short circuit terminations (shorts) are used to establish reference planes in transmission systems and as key elements in the calibration of vector network analyzers (VNAs). Offset shorts can be used for banded calibrations of VNA. Those with the longest offset are often used to evaluate the calibration effectiveness of a VNA by measuring the effective source match after calibration.
Maury Microwave
Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.