Brandywine - PMC SyncClock32 CC TURBO Conduction cooled PMC timing plug-in
- IRIG A & B, NASA 36 and 1 PPS inputs
- HaveQuick sync option
- Propagation delay compensation
- Zero latency time reads
- Match time output
- External event time tags
- Three user programmable rates
- Conduction cooled
The PMC-SyncClock32 from Brandywine Communications is an advanced Mezzanine Card (PMC) module. Precision time is provided to the host computer with zero latency. The onboard microprocessor automatically synchronizes the clock to reference signal inputs. The reference signal inputs handled by the PMC in its standard configuration are IRIG’s A and B, NASA 36 and 1 PPS. Alternatively, the clock in the PMC can be set using commands from host computer and free run using its on-board oscillator as the time base.
More Product Information
- IRIG’s A and B and NASA 36 time code inputs
- +3.3V or +5V signalling
- 1PPS Sync input
- External Event (Time Tag) input
- Three programmable pulse rate outputs
- Match Time output
- Industrial Temperature Range option
- Optional on-board GPS option
- Optional HaveQuick input/output
- Optional IRIG B time code output
- High performance GPS disciplined Time/Frequency standard
- Ethernet Interface for management and control
- Network Time Protocol (NTP)
- Multiple 1PPS outputs with individual delay compensation
- Multiple Low Phase Noise 10MHz outputs with software programmable level
- Time Code outputs including Have Quick, IRIG A, IRIG B, IRIG E, IRIG G
- Sync to GPS or to Have Quick/1PPS per ICD-GPS-060
- Choice of internal disciplined OCXO or Rubidium Oscillator
- Uses optical-pumping cesium technology rather than magnetic selection for higher stability and longevity.
- Fully compliant with ITU-T G.811 PRC / G.811.1 ePRC standards.
- Supports essential timing outputs such as BITS, PPS (1PPS), and analog frequency.
- Compact, modular design suitable for deployment in racks, enabling scalable deployment across telecom, defense, utilities, and data-center environments.
- Long service life and improved holdover performance — offering enhanced reliability even during extended GNSS disruptions.
- Remote and secure management capabilities, including support for SNMPv3 and integration with orchestration/management suites (e.g. Mosaic Controller).
- Accurate & reliable time data from a trusted source
- Remote configuration and status via web browser, remote monitoring with SNMP
- Synchronization between users – eradicates discrepancies
- System time stamping, such as e-commerce transactions, e-mail sent & received, is highly accurate
- Automatic systems procedures such as backups occur at the correct time and in the correct order
- Additional time signal outputs can feed to other systems
- Multiple time source fall back and priority configuration can ensure high synchronization availability
- Various oscillator choices allow for long holdover to maintain time accuracy when synchronization signals are absent
- First commercial high-performance cesium atomic clock using optical pumping — 100 times more atoms can be measured compared to magnetic clocks.
- Offers 10 times higher clock stability.
- Double the operational lifetime compared with traditional magnetic cesium clocks.
- Wide range of ultra-low noise frequency outputs (e.g. 5 MHz, 10 MHz, 100 MHz) — plus multiple 1PPS outputs, supporting high-precision timing distribution.
- Frequency accuracy ≤ ±5 × 10⁻¹³; reproducibility after power cycle ≤ ±1 × 10⁻¹³.
- Adjustable frequency offset: resolution ±1 × 10⁻¹⁵, range ±1 × 10⁻⁹.
- Rack-mount (3RU, 19″)
- 5 MHz or 10 MHz Outputs Available
- Reference Frequency Input Option
- Auto Changeover with Ref. Input Option
- Low Phase Noise Outputs
- Twenty four Outputs
- Front Panel Status Indicators
- Fault Discrete Inputs
- Compact 1U, 19” rack mount
- 3/4 length board (1/2 size available w/o GPS input)
- Optional Have Quick synchronization input
- IRIG’s A and B and NASA 36 time code inputs
- 1PPS sync input
- IRIG B output option
- 1PPS and time code inputs are redundant
- Single-slot including GPS option
- Zero latency time reads
- External Event input (optional eight or sixteen inputs)
- Match Time output
- Programmable Heartbeat rate
- Network Enabled Distribution Amplifier
- Low Phase Noise Reference Frequency Outputs
- Fault Alarm Output
- 1U 19″ Rack Mount
- Frequency Synthesizer Option
- Hitless Switching of Reference
- Programmable Amplitude
- Propagation Delay Compensation
- 10 MHz Standard, Other Frequencies Available
- Wide Input Bandwidth
- Input Isolation
- Automatic & Manual Changeover
- Transformer Coupled Outputs
- Twenty four Outputs
- Front Panel Status Indicators
- Fault Discrete Inputs
- Compact 1U, 19” rack mount
Brandywine Communications
Website
Video Compression, Time & Frequency Stds, GPS and Board Level Timing Solutions