Advanced Illumination - DL097 Medium Dome Light
- Rugged, cast aluminum housing has an outer diameter of 8.4” (213mm) and an inner, working diameter of 6.1” (155mm).
- The Medium Dome Light is available in a wide range of wavelengths including a 3 channel, RGB configuration.
- Provides up to 59kLux at a 1” (25mm) standoff.
General Specs
|
Electrical Specifications |
Color |
24V Current |
All Other Controls |
|---|---|---|---|
|
RGB |
0.72A |
TBD |
|
|
455, WHI |
0.72A |
1.08A Max |
|
|
470, 505, 530, 590 |
0.72A |
1.01A Max |
|
|
625, 660, 730, 880, 940 |
0.72A |
0.76A Max |
|
|
Normal Operating Temperature |
0 - 60°C |
||
|
Weight |
1369.9g (48.32oz) (3.02lb) | ||
|
Standard Cable Information |
2 m long -0/+150 mm (80" -0/+6") - 105°C rated PVC jacket, foil shield with drain. |
||
|
Photobiological Risk Factor |
Exempt Applicable Wavelengths: 850, 940 Group 1 (Low-Risk) Applicable Wavelengths: 455, 505, 530, 590, 625, 660, 730, WHI, RGB Group 2 (Moderate-Risk) Applicable Wavelengths: 470 |
||
|
Compliance |
CE, RoHS, IEC 62471 |
||
|
IP Rating |
Not Rated |
||
|
Lumen Maintenance |
L70 = 50,000 Hours |
||
Mechanical Specs
Optical Specs

Electrical Specs
Control Specs
Part Number Key

More Product Information
- The SL243 Spot Light provides an industry leading performance to size ratio while maintaining desirable thermal dissipation. Perfect for applications that require small footprint machine vision components.
- Available in a broad range of wavelengths
- Washdown Version Available
- Convenient M4 T-Slot for Mounting
- The AL143, 2×3 Spot Light is available in a wide range of wavelengths with multiple lens options.
- Ideal Illumination for medium working distances.
- Convenient mounting with an M4 nut channel.
- Washdown version is available
- High-Intensity Illumination in a Compact Package
- Available in a broad range of wavelengths
- Washdown Version Available
- Convenient M4 T-Slot for Mounting
- The BL128 Series provides a compact linear backlight solution ideal for space-constrained line scan applications.
- Its ultra-thin profile (less than ½”) minimizes vertical footprint, and bezel-free design along the length allows for placement of its emitting window right up to adjacent surfaces.
- While optimized for line scan setups, the BL128’s versatility extends to general-purpose machine vision lighting as a non-directional, highly diffuse bar light illuminator when needed.
The laboratory and research industry faces unique challenges including long-standing, legacy pain points and frequently evolving needs. These include paramount safety and regulatory requirements for lab workers and patients alike, the need for high containment and sterility, and the integration of cutting-edge technologies. Complex and sensitive facilities require specialized testing solutions to ensure compliance, safety, and reliability. Effective planning and laboratory design and construction are crucial to creating environments that support advanced research and manufacturing processes, especially in the pharmaceutical and medical device sectors.
- Universal input switching supply
- 24v regulated current DC – runs on 110-220v AC
- Power indicator light
- Tinned leads; marked negative/positive with wire nuts for easy connection
- Specific object size - depending on the production line
- Quick and very easy measurement
- Little training required
- Measuring software VELOX included
- Compatible with all database software of the VCP family
- Various external CAQ software are connectable
- Low operator influence due to fixed focusing as well as preset illumination
- Robust design and simple, user-friendly operation
- Shock and vibration resistant due to an optimised sensor arrangement and balanced weight distribution
- Measuring software enables various operator level settings (production, laboratory, administrator, service, etc.)
- Standardized individual components lead to supply security and therefore a short delivery period
- Easy connection with external devices
- Guaranteed performance to 43.5 GHz with Extended K™ ports
- High output power allows measurement of high attenuation devices
- Advanced time domain option provides tools for signal integrity analysis
- Wide dynamic range enables measurement of very low reflection artifacts
- Excellent corrected directivity minimizes measurement uncertainty
- SmartCal™ auto calibration unit reduces calibration and setup time
- Time domain with time gating option grants easier and faster fault identification
- Modern LAN interface for remote control is faster than GPIB
- A common GUI and SCPI interface within the ShockLine family
- Bias tee option simplifies test setups where the DUT needs DC biasing
- Universal Fixture Extraction (UFX) software option provides advanced de-embedding tools for test fixture extraction
- E-Band VNA
- Extended frequency range covering E-band and major parts of V band
- Fully assembled test system eliminates setup errors and increases reliability
- Tethered modules connect directly to the DUT increasing measurement stability
Optimized Measurement Setup
- Multi-purpose SIGMA instrument integration kit
- Shorter cabling and universal chuck connection
- Triax probe with protected guard
- Optimized signal path
- Safe probe tip exchange
- Seamless integration of various analyzers
High Power Chuck
- Triax design for low-leakage measurements up to 3 kV
- Special chuck surface coating
- High-isolation ready
- High-current measurement up to 100 A with lowest contact resistance
- Optional upgrade for 10 kV (coax) operating voltage
- Thin wafer handling capability
Safe Operation
- Arcing protection
- Shield Enclosure with interlock
- Advanced grounding concept
- Maximum protection from high-voltage shock for users and devices
- Common ground protection for all instruments
- EMI/light-tight shielded environment
Advanced Illumination