Anritsu - MS2760A - Spectrum Master Ultraportable Spectrum Analyzer

  • First portable spectrum analyzer to provide continuous frequency coverage to 170 GHz
  • Broadband mmWave capabilities for radio astronomy, automotive radar, wireless backhaul, 802.11ad, satcom, and more
  • Ultraportable form factor enables measurements right at the device under test
  • Measure: channel power, adjacent channel power, occupied bandwidth
  • Patented NLTL technology provides > 100 dB dynamic range
  • -141/-136/-129/-122 dBm DANL to 90/110/145/170 GHz ( Spectrum Master MS2762A)
  • Up to 6 traces, 3 trace detectors, and 12 markers
  • Standard three-year warranty

Specifications

Model MS2760A MS2762A
Frequency Range

MS2760A-0032 9 kHz – 32 GHz

MS2760A-0044 9 kHz – 44 GHz

MS2760A-0050 9 kHz – 50 GHz

MS2760A-0070 9 kHz – 70 GHz

MS2760A-0090 9 kHz – 90 GHz

MS2760A-0100 9 kHz – 110 GHz

MS2760A-0145 9 kHz – 145 GHz

MS2760A-0170 9 kHz – 170 GHz

MS2762A-0032 6 GHz – 32 GHz

MS2762A-0044 6 GHz – 44 GHz

MS2762A-0050 6 GHz – 50 GHz

MS2762A-0070 6 GHz – 70 GHz

MS2762A-0090 6 GHz – 90 GHz

MS2762A-0100 6 GHz – 110 GHz

MS2762A-0145 6 GHz – 145 GHz

MS2762A-0170 6 GHz – 170 GHz

Dynamic Range
2/3 (TOI to DANL) 1 Hz RBW
>103 dB @ 70 GHz >108 dB @ 70 GHz
DANL (RMS detection)
1 Hz RBW, IF Gain = On

-130 dB typ (70 – 90 GHz)

-120 dB typ (110 – 145 GHz)

-141 dB typ (70 – 90 GHz)

-129 dB typ (110 – 145 GHz)

RF Connector
*K = 2.92 mm
(compatible with SMA and 3.5 mm)
*V = 1.85 mm
(compatible with 2.4 mm)
*W1 = 1.0 mm

MS2760A-0032 K* (m) connector

MS2760A-0044 K* (m) connector

MS2760A-0050 V* (m) connector

MS2760A-0070 V* (m) connector

MS2760A-0090 W1* (m) connector

MS2760A-0100 W1* (m) connector

MS2760A-0145 0.8 mm (m) connector

MS2760A-0170 0.8 mm (m) connector

MS2762A-0032 K* (m) connector

MS2762A-0044 K* (m) connector

MS2762A-0050 V* (m) connector

MS2762A-0070 V* (m) connector

MS2762A-0090 W1* (m) connector

MS2762A-0100 W1* (m) connector

MS2762A-0145 0.8 mm (m) connector

MS2762A-0170 0.8 mm (m) connector

Amplitude Accuracy ±0.5 dB, typical (20°C to 30°C) ±0.5 dB, typical (20°C to 30°C)
Frequency Accuracy Accuracy: ± 0.2 ppm (25°C ± 25°C) + aging
Aging: ± 1.0 ppm per year
Accuracy: ± 0.2 ppm (25°C ± 25°C) + aging
Aging: ± 1.0 ppm per year             

Options

Available Models

Models Description
MS2760A-0032 9 kHz to 32 GHz Spectrum Master, ultraportable spectrum analyzer
MS2760A-0044 9 kHz to 44 GHz Spectrum Master, ultraportable spectrum analyzer
MS2760A-0050 9 kHz to 50 GHz Spectrum Master, ultraportable spectrum analyzer
MS2760A-0070 9 kHz to 70 GHz Spectrum Master, ultraportable spectrum analyzer
MS2760A-0090 9 kHz to 90 GHz Spectrum Master, ultraportable spectrum analyzer
MS2760A-0110 9 kHz to 110 GHz Spectrum Master, ultraportable spectrum analyzer
MS2760A-0145 9 kHz to 145 GHz Spectrum Master, ultraportable spectrum analyzer
MS2760A-0170 9 kHz to 170 GHz Spectrum Master, ultraportable spectrum analyzer
   
MS2762A-0032 6 GHz to 32 GHz Spectrum Master, ultraportable spectrum analyzer
MS2762A-0044 6 GHz to 44 GHz Spectrum Master, ultraportable spectrum analyzer
MS2762A-0050 6 GHz to 50 GHz Spectrum Master, ultraportable spectrum analyzer
MS2762A-0070 6 GHz to 70 GHz Spectrum Master, ultraportable spectrum analyzer
MS2762A-0090 6 GHz to 90 GHz Spectrum Master, ultraportable spectrum analyzer
MS2762A-0110 6 GHz to 110 GHz Spectrum Master, ultraportable spectrum analyzer
MS2762A-0145 6 GHz to 145 GHz Spectrum Master, ultraportable spectrum analyzer
MS2762A-0170 6 GHz to 170 GHz Spectrum Master, ultraportable spectrum analyzer

Calibration Options

Options Description
MS276xA-0098 Standard Calibration (ANSI Z540-1-1994) for the MS276xA models
MS276xA-0099 Premium Calibration (ANSI Z540-1-1994 plus test data) for the MS276xA models             

Accessories

Adapters

Model Number Description
1091-456-R Adapter, 49.9 to 67.0 GHz, WR15 to V(f)
1091-457-R Adapter, 39.3 to 59.7 GHz, WR19 to V(f)
1091-458-R Adapter, 33.0 to 50.1 GHz, WR22 to V(f)
1091-459-R Adapter, 26.4 to 40.1 GHz, WR28 to V(f)
1091-460-R Adapter, 17.6 to 26.7 GHz, WR42 to V(f)

Inline Adapters

Model Number Description
1091-402-R Inline Adapter, W1 (f) to WR15, 50 to 75 GHz
1091-401-R Inline Adapter, W1 (f) to WR12, 60 to 90 GHz
1091-400-R Inline Adapter, W1 (f) to WR10, 75 to 110 GHz
2000-1889-R Inline Adapter, K (f) to WR42, 17.6 to 26.7 GHz
2000-1890-R Inline Adapter, K (f) to WR28, 26.4 to 40.1 GHz
2000-1880-R Coaxial Adapter, V (f) to N (m), DC to 18 GHz, 50 Ω
2000-1881-R Coaxial Adapter, V (f) to N (f), DC to 18 GHz, 50 Ω

Cables and Extenders

Model Number Description
2000-1605-R BNC(m) - MCX(m) Cable, 1.5 meters
2000-1859-R USB 3.0 Type C to Type A Cable, 1m
2000-1888-R USB 3.0 Extender Cable, 10m
2000-1917-R 100m USB CAT 6A/7 extender
2000-1918-R 200m USB multimode fiber extender

Directional Horn Antennas

Model Number Description
2000-1867-R 17.6 to 26.7 GHz, WR42, 25 dBi gain
2000-1868-R 26.4 to 40.1 GHz, WR28, 25 dBi gain
2000-1869-R 33.0 to 50.1 GHz, WR22, 25 dBi gain
2000-1870-R 39.3 to 59.7 GHz, WR19, 25 dBi gain
2000-1871-R 49.9 to 75.8 GHz, WR15, 25 dBi gain
2000-1872-R 60.0 to 90.0 GHz, WR12, 25 dBi gain
2000-1873-R 75.0 to 110.0 GHz, WR10, 25 dBi gain             

Low Noise Amplifiers

These low noise amplifiers (LNAs) are specially designed to supplement the performance of the MS276xA ultraportable spectrum analyzers. With approximately 28 dB of gain, these LNAs will improve sensitivity by approximately 20-22 dBm in the frequency range from 18 to 42 GHz.

Model Number Description
2000-1929-R

Fits models
MS276xA-0050
MS276xA-0070

Frequency Range: 18 - 42 GHz
Gain: 28 dB
Noise Figure: 4 dB
RF Connector: V(m) – V(f) output
Max RF input level: -5 dBm, (0 dBm damage level)
Specification temperature: +25°C
2000-1930-R

Fits models
MS276xA-0032
MS276xA-0044

Frequency Range: 18 - 42 GHz
Gain: 28 dB
Noise Figure: 4 dB
RF Connector: K(m) – K(f) output
Max RF input level: -5 dBm, (0 dBm damage level)
Specification temperature: +25°C
2000-1933-R USB power bank (for use with the MS276xA Low Noise Amplifier accessory)

Industries

More Product Information

Anritsu

Since its founding in 1895, Anritsu has been a pioneer in the telecommunications field, marking its 120 years of growth with achievements that include creating the world’ s first practical wireless telephone, which paved the way for today’s smartphones. We would like to express our sincere gratitude to our customers and everyone else who has made this possible.

With its measurement business as the pillar supporting the further advancement of its mobile broadband services, Anritsu offers solutions that are indispensable for building a safer and more secure society in a broad range of fields including quality assurance inspection equipment for foods and pharmaceutical products, remote monitoring and control systems, traffic shapers, and high-speed electronic devices.


Contact Details

US Headquarters Anritsu Corporation

490 Jarvis Drive, Morgan Hill, CA 95037-2809

Phone (Toll-free/All locations): 1-800-Anritsu (1-800-267-4878) for Sales, Technical and Service

Contact page

Test & Measurement

Download Line Card
Anritsu - MS2760A - Spectrum Master Ultraportable Spectrum Analyzer