4 Independent Channels, 1 Output Connector
-
Includes built-in pre-programmed sequencing.
-
Provides control for computational imaging, including photometric stereo, extended depth of field, combined bright field + dark field, high dynamic range, and high resolution color.
-
Ideal for multi-channel lights and multi-light stations. Due to power output constraints, some configurable light lengths may be limited.
-
Housed within a compact enclosure with DIN rail mounting.
-
Driven with SignaTech™ for improved safety and easy operation.
-
NOTE: NOT COMPATIBLE WITH C1 CONNECTORS
NoiseKen - High Voltage Noise / Car Manufacturer's Standard by FNS-AX3-A16C-N1969
This model is for carrying out a high pressure noise test of individual automotive manufacturers' demands. It simulates representative high voltage noise of HV and EV.
- Single-phase 3 wire
- AC85 - 240V16A
- 50/60Hz
- DC125V16A
- Pulse: ~ 500V 50kHz (option)
CALIBRATION CIRCUIT (18-N1686)
TESTING CONDITION 1 ( CONTINUAL TESTING)
Testing Level (Continual Testing)
Test level | Vp-p(V) |
1 (battery ECU) | 220 |
2 (PCU) | 105 |
3 (NAVI) | 15 |
Testing Frequency fp condition (Continual Testing)
Test level | Vp-p(V) |
1 (battery ECU) | 220 |
2 (PCU) | 105 |
3 (NAVI) | 15 |
CONDITION 2 (BURST TESTING)
Testing Level (Burst Testing)
Test level | Vp-p(V) |
1 (battery ECU) | 120 |
2 (PCU) | 30 |
3 (NAVI) | 7.5 |
Test Frequency fp condition (Burst Testing)
Test Frequency fp range (kHz) | 100 ~ 1000 (kHz) |
Test fp step (kHz) | 10 (kHz) |
Test Frequency fp point | 90 frequency point |
REQUIRED ADAPTOR
Coupling Adaptor MODEL: CA-805B (Capacitive coupling)
Enable for testing characteristics against the noise only with clamping communication cables of electronics equipments in combination with INS Series.
Enable for testing characteristics against the noise only with clamping communication cables of electronics equipments in combination with INS Series.
- Enable to inject the noise without cutting signal, DC, AC, GND, etc.
- Enable to test the noise resistibility of electronics equipments separated individually.
- Realize to test the noise resistibility effectively since the injection can be directly to signal lines.
- Enable to clamp bundle of signal lines whose maximum diameter is 26mm
Input voltage : | 4000V Max |
Input pulse width : | 50~1000ns |
Dimension / Mass : | (W) 350 X (H) 120 X (D) 130mm / approx. 3kg |
Storage temp. range : | -5~55℃ |
Inside clamp diameter : | 26mm |
More Product Information