IntelliPower - FA10378 Rugged UPS
-
3000 VA, 2700 W, 115 VAC, 60 Hz input and 120 VAC, 60 Hz output, double conversion, rugged, high temperature, isolated, On-Line UPS with Lead Acid 8 battery hot swap drawer, optional EBP, with 1399 power factor correction for Navy shipboard applications
TYPE | SPECIFICATION |
---|---|
Power Rating | 225W |
Chassis Configuration | 3U, ≥24"D |
Input Voltage | 115 VAC |
Input Frequency | 50/60 |
Input Connector | Circular Mil |
Output Voltage | 110 VAC |
Output Frequency | 50/60 |
Output Connector | NEMA Type |
Battery Runtime | < 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Hot Swap |
Communication | SNMP |
More Product Information
-
2000VA, 1800W 120/240VAC & 28DC Input & 120VAC,60Hz Output, Double Conversion, Rugged, High Temperature, Isolated, Online UPS System with Hot Swap Battery, Frequency Conversion, Power Factor Conversion and SNMP Communications
-
The RL113 High Intensity Bright Field ring light offers a very wide array of wavelengths from UV to IR.
-
With intensities of up to 45.5kLux at 12” (300mm), the RL113 is particularly well suited to longer working distances.
-
A rugged, heavy enclosure, compliant with IP67 requirements, is well suited to demanding environments.
-
Double Conversion, Rugged, High Temperature, Isolated, On Line UPS in 3U-20.63”D Rack Mountable Enclosure with Power Factor Correction, Cold Start, SNMP, 120VAC, 50/60Hz Input and 120VAC, 60Hz Output
-
3KVA, 2.1KW double conversion, online, isolated, global input, rugged UPS with 120vac output, frequency conversion, power factor correction and extended internal batteries for military applications
-
Double Conversion, Rugged, Isolated, On Line UPS System with Frequency Conversion and Power Factor Correction
-
3000VA, 2250W, 115VAC 50/60Hz Input and 120VAC 60Hz Output, Double Conversion, On Line, High Temperature, Isolated, Rugged UPS with Power Factor Correction for Military Applications
-
5KVA, 4KW Double Conversion On-Line Isolated. 230VAC, 50/60Hz Input UPS with 230VAC, 60Hz Output, Frequency Conversion, Power Factor Correction and SNMP Communications for Military Applications
-
High Temperature, Double Conversion, Rugged, Isolated, Rack Mounted UPS System with Power Factor Correction for Navy Shipboard Applications
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form