External battery pack (EBP) with 10 10.5Ah lead acid batteries fixed within a 2U aluminum chassis
TYPE | SPECIFICATION |
---|---|
Chassis Configuration | 2U, ≤23"D |
Output Connector | Terminal Block |
Battery Runtime | ≥ 20 minutes |
Battery Chemistry | Pb Lead Acid |
Battery Configuration | Fixed |
More Product Information
-
3KVA, 3KW Double Conversion On Line Isolated 115VAC Input UPS, and simultaneous 120 and 240VAC 60Hz Output, Power Factor Correction, Extended Internal Batteries, SNMP Communications for Military Applications
-
2000VA, 1800W 120/240VAC & 28DC Input & 120VAC,60Hz Output, Double Conversion, Rugged, High Temperature, Isolated, Online UPS System with Hot Swap Battery, Frequency Conversion, Power Factor Conversion and SNMP Communications
-
3000VA, 2400W, Isolated 120VAC Single Phase 50/60Hz Input and 120VAC, 60Hz Output, Double Conversion Input, On Line UPS and Power Conditioning System with 9 Lithium Iron Phosphate batteries and Power Factor Correction for Commercial Applications
-
1500 VA, 1350 W, 115 VAC at 60 Hz input and 115 VAC at 60 Hz output, double conversion, rugged, high temperature, isolated, on-line UPS with hot swap battery drawer and power factor correction for Navy shipboard applications
-
Rugged Rack Mount, Double Conversion On-Line UPS & Isolated Power Conditioning System with Power Factor Correction, Front Panel Hot Swap Battery & SNMP Communications for Military Applications in a 1U Enclosure
-
3000VA, 2400W, 270VDC Input and 115VAC, 60Hz Output, Isolated Rugged Extreme High Temperature Rack Mounted Power Converter in an aluminum enclosure
-
108V, 2 strings of 9 VRLA batteries in a 3U, 24-inch-deep enclosure
-
3kVA, 3kW High Temperature, Double Conversion, On-Line, Isolated, 230VAC, 50/60Hz Input UPS with 120VAC, 60Hz Output, Power Factor Correction and Extended Internal Batteries
IntelliPower, Inc.
IntelliPower, Inc., located in Orange, California, has been designing, manufacturing and supporting high-performance, cost effective Uninterruptible Power Systems (UPS) and frequency/voltage conversion solutions to protect mission-critical applications since 1988. IntelliPower’s on-line, double conversion UPS, power conditioner and frequency/voltage converter solutions utilize digitally controlled, high-efficiency power switching technology that has been proven for over 32 years on numerous platforms.
Customers with demanding environments use IntelliPower’s rugged products because of our proven record of providing outstanding solutions. IntelliPower’s in-house development proprietary circuit design, DSP firmware/software technology and wide range of enclosure designs, give IntelliPower unmatched capabilities to deliver systems configured to customer requirements backed by expert support.
Our ability to design and configure quickly is based on our standard proprietary subassemblies that go into variations of our power systems as required. Our product configurator tools and application engineers allow you to easily define your requirements and obtain your proposal for solutions that exactly meet your needs.
Contact Details
IntelliPower, Incorporated
1746 North Saint Thomas Circle, Orange, California 92865, USA
Phone: 714-921-1580
Fax: 714-921-4023
Email: ca-ora-sales@ametek.com
Contact form