FormFactor - Cascade ACP Probe – Coaxial Long-lasting, rugged RF and microwave on-wafer probes
-
Unique Air Coplanar tip design with choice of beryllium copper (BeCu) or tungsten tip material
-
DC to 110 GHz models available in single and dual line versions
-
Low insertion and return loss with ultra-low-loss ( -L ) versions
-
Excellent crosstalk characteristics
-
Wide operating temperature -65 ° C to + 200 ° C
-
Wide range of pitches available, from 50 to 1250 µm
-
Individually supported contacts
-
Reduced contact (RC) probe tips for small pads
-
BeCu tip provides rugged, repeatable contact on gold pads
The Air Coplanar Probe (ACP) is a rugged microwave probe with a compliant tip for accurate, repeatable measurements for both on-wafer as well signal integrity applications. It features excellent probe-tip visibility and the lowest loss available. The ACP Probe delivers outstanding compliance for probing non-planar surfaces. These probes offer stable and repeatable over-temperature measurements, with a typical probe life of 500,000 contacts on gold pads. Configurations for both single and dual signal applications are available. The ACP probe combines outstanding electrical performance with precise probe mechanics, and is today’s most widely used microwave probe. Fast delivery is available on 100, 125, 150, 200, and 250 µm pitched probes
More Product Information
-
Long holding time: 80 hours with 10 STP liter He-3 gas
-
Stable He-3 pot temperature: Separate sippers for 1K pot and the charcoal sorb cooling line
-
Sample can be loaded or removed when the cryostat is cold
-
Low noise, low vibration
-
Multiple operation modes: He-3 cryostat can be operated without pumping the 1K pot (referred to as 4K operation mode)
-
Different substrate carriers for wafers up to 200 mm or single dies
-
Probe cards and/or up to eight positioners
-
Ice- and condensation-free probing down to 77 K (liquid nitrogen) or below 20 K (liquid helium)
-
Probe positioners placed inside vacuum chamber
-
Joystick controller
-
Manual probe positioners with rotary feed-throughs
-
User-centered design minimizes training costs and enhances efficiency
-
Comprehensive alignment functions – from simple wafer alignment and mapping to automated alignment and test of multiple singulated chips, like IR – Focal Plane Arrays
-
Low running costs, less vibration, less noise, reduced maintenance
-
Large convenient experimental access: Up to 12 line-of-sight ISO100 ports located on perimeter of plates
-
CMN calibrated thermometry on MC plate
-
Operation via touch panel controller: Remote operation via ethernet interface
-
Ease of use – Less experienced operators can perform an RF calibration up to 500 GHz by simply pushing a button. This reduces the need of experienced users full time on each system.
-
Reduced Soak Time – The system will automatically re-align the probes to the pads if they drift from alignment. This reduces test time and increases throughput.
-
Unattended Use – Measurements can be left running over night or the weekend, testing all devices on the wafer, and at different temperatures without the need of an operator.
-
Calibration Monitor and Re-calibration – System will
continuously monitor calibration drift, and automatically re-calibrate the system should the drift exceed a predefined limit.
-
Superior field confinement reduces unwanted couplings to nearby devices and transmission modes
-
Superior measurement accuracy and repeatability
-
Small scrub minimizes damage to aluminum pad
-
Typical contact resistance < 0. 05 Ω on Al, <0.02Ω on Au
-
Save valuable wafer space and reduce pad parasitics by being able to shrink pad geometries to 25 x 35 µ m (best case)
-
Different substrate carriers for wafers up to 200 mm or single dies
-
Probe cards and/or up to eight positioners
-
Independently cooled cold shield
-
Probe positioners placed inside vacuum chamber
-
Intuitive, manual drives
-
Front loading capability through load door
-
Independent control of linear chuck stage and positioners
-
Contact/separation stroke for chuck
-
Combination of DC and RF in a single probe module: One dual probe or a maximum of three RF; a maximum of 9 DC standard (other quantities upon request).
-
Utilizes ACP tip design, GSG, GS or SG
-
RF tips available from DC to 110 GHz
-
Choice of BeCu or tungsten tips
-
DC power needles come standard with 100 pF microwave capacitor
-
Power bypass inductance: 8 nH
-
Maximum DC voltage: 50 V without power bypassing (25 V with standard power bypassing, and component dependent with custom power bypassing)
-
Ideal for probing the entire circuit for functional test
-
Dual ACP configuration supports differential signaling applications
-
DC probes can provide power or slow logic to circuit under test
-
Wafer temp verified <4.5 K (with 44 RF probes in contact)
-
Magnetic field suppression to <200 nT
-
Easy exchange of customizable probe cards
-
Configurable for 150 mm, 200 mm and 300 mm wafers
-
Options for fully automated wafer load or manual
-
Complete software suite for manual, semi-auto, or fully automated probing
-
25 wafer cassette capacity for fully automated testing
-
~15 minute cooldown time per wafer
FormFactor, Inc.
FormFactor, Inc. (NASDAQ:FORM) is a leading provider of essential test and measurement technologies along the full IC life cycle – from characterization, modeling, reliability, and design de-bug, to qualification and production test.
We constantly strive to help our customers solve the advanced test and measurement challenges of the broader semiconductor industry. Our focus on customer partnership, innovation, agility and operational excellence allows us to earn sustainable business every day.
Contact Details
FormFactor, Inc. Corporate Headquarters
7005 Southfront Road, Livermore, CA 94551, USA
Phone: 925-290-4000