Montena Technology - Transient Generators
See "Specifications & Details" tab for more information.

|
MIL-STD 461 Compliant: Meets stringent military standards for reliable testing. |
|
Flexible Configurations: Available as standalone (PG-CS115) or modular (M-CS115) units. |
|
Comprehensive Accessories: Optional injection probe, attenuator, oscilloscope, and control software. |
|
High Precision: Delivers accurate rectangular pulses with rapid rise/fall times (≤ 2 ns). |
|
Versatile Testing: Supports single and repetitive pulse rates from 1 to 50 Hz. |
|
Compact Design: Lightweight and portable, ideal for various testing environments. |
|
Reliable Performance: Durable construction ensures long-term use in demanding settings. |
|
Enhance your EMC testing with the CS115 Pulse Generator—precision, compliance, and versatility combined. |

|
MIL-STD-1275F Compliant: Dedicated design for conducted susceptibility testing on 28 VDC circuits. |
|
Spike & Surge Testing: Handles spikes up to 250 V / 250 mJ and surges up to 100 V / 1210 J. |
|
High Current Capability: 16 A continuous or up to 400 A with the optional DM400 decoupling diode module. |
|
Adjustable Waveforms: Configurable rise times, pulse durations, and voltages for precise test conditions. |
|
User-Friendly Control: Remote interface via RS232 or USB, with optional control software for automated testing. |
|
Enhance your EMC testing with the 1275F Pulse Generator—precision, compliance, and versatility combined. |

|
MIL-STD 461 CS116 Compliant: Meets stringent military testing standards. |
|
Flexible Frequency Options: Choose from 6, 9, or 17 test frequencies. |
|
Comprehensive Accessories: Includes injection probe, attenuator, oscilloscope, and control software. |
|
Efficient Operation: Single signal output reduces test time and supports automation. |
|
User-Friendly Control: Easily controlled via RS232 and USB interfaces. |
|
Robust Design: Durable construction with wide power compatibility (90–264 Vac). |
|
Upgradable: Add CS115, CS106, CS114 |
|
Optimize your naval and industrial testing with the CS116 Damped Sinusoid Generator—precision and efficiency combined. |

|
High Voltage Capability: Generates electrostatic discharges up to 300 kV with reversible polarity. |
|
Adjustable Electrode: Height adjustable from 1.5 to 6 meters and tilt up to ±60° for precise targeting. |
|
Standards Compliance: Meets MIL-STD-331, MIL-STD-464, NATO AECTP-250, AECTP-500, and more. |
|
Automated Operation: PC-based software for remote control, calibration, and test reporting. |
|
Enhanced Safety: Fiber optic interface ensures operator safety by isolating the control system from high-voltage equipment. |
|
Versatile Testing: Supports multiple discharge scenarios, including personnel-borne and helicopter-borne ESD tests. |
|
Durable Design: Built for demanding military and industrial testing environments. |

|
POG-CS116-CS115 Test Generator, Dampened Wave and Switch Transients |
|---|
|
MIL-STD 461 CS115+CS116 Compliant: Meets stringent military testing standards. |
|
Flexible Frequency Options: Choose from 6, 9, or 17 test frequencies. |
|
Comprehensive Accessories: Includes injection probe, attenuator, oscilloscope, and control software. |
|
Efficient Operation: Single signal output reduces test time and supports automation. |
|
User-Friendly Control: Easily controlled via RS232 and USB interfaces. |
|
Robust Design: Durable construction with wide power compatibility (90–264 Vac). |
|
Optimize your naval and industrial testing with the CS116 & CS115 Damped Sinusoid & Switch Transient Generator—precision and efficiency combined. |

|
TS-CS114-CS115-CS116 TurnKey Test System for MIL-STD-461 CS114, CS115, CS116 |
|---|
|
Automatic calibration for the whole test frequency range |
|
Application of all test frequencies automatically. The level can be selected or automatic. |
|
NO need to manually configure the measurement equipment |
|
NO need to manually integrate the transfer function of probes and attenuators |
|
Generation of test reports: NO need to record all values read from the measurement equipment |
|
Generation of calibration reports: NO need to record all calibration setting parameters |
|
Rack together and add CS101, CS109, and RS101 (sections 18, 19, and 20 of the RTCA DO-160G are also available.) |

|
Compliance: Meets MIL-STD-461 RS105 standards for NEMP testing. |
|
High Precision: Generates a minimum electric field of 50 kV/m, with higher fields available for smaller devices. |
|
Portable Design: Easy to move frame and compact design for versatile placement options |
|
User-Friendly: Controlled via computer with RS232 and USB interfaces. |
|
Versatile Testing: Use an Existing Chamber and get the maximum size test volume. non-permanent install when needed |
|
Robust Specifications: Quick rise time of 2.3 ns and pulse length of 23 ns, ensuring accurate and reliable results. |

|
Compliance: Meets MIL-STD-461 RS105 standards for NEMP testing. |
|
High Precision: Generates a minimum electric field of 50 kV/m, with higher fields available for smaller devices. |
|
Portable Design: Tabletop Easy-to-move frame and compact setup for versatile placement. |
|
User-Friendly: Controlled via computer with RS232 and USB interfaces. |
|
Versatile Testing: Ideal for assessing small electronics like printed circuit boards and subsystems. |
|
Robust Specifications: Quick rise time of 2.3 ns and pulse length of 23 ns, ensuring accurate and reliable results. |

|
Compliance: Meets MIL-STD-461 RS105 standards for NEMP testing. |
|
High Precision: Generates a minimum electric field of 50 kV/m, with higher fields available for smaller devices. |
|
Portable Design: Easy-to-move frame and compact setup for versatile placement. |
|
User-Friendly: Controlled via computer with RS232 and USB interfaces. |
|
Versatile Testing: Ideal for assessing small electronics like printed circuit boards and subsystems. |
|
Robust Specifications: Quick rise time of 2.3 ns and pulse length of 23 ns, ensuring accurate and reliable results. |

|
NEMPxxxx-O - Outdoor Permanent RS105 Test Systems < 50kV/m, Different standard sizes |
|---|
|
Compliance: Meets MIL-STD-461 RS105 standards for NEMP testing. |
|
High Precision: Generates a minimum electric field of 50 kV/m, with higher fields available for smaller devices. |
|
Permanent Design: to stand up to the yearly weather, whether elements, wind, snow, or ice. |
|
User-Friendly: Controlled via computer with RS232 and USB interfaces. |
|
Versatile Testing: Ideal for assessing Large electronics, systems, and subsystems. |
|
Robust Specifications: Quick rise time of 2.3 ns and pulse length of 23 ns, ensuring accurate and reliable results. |

|
Compliance: Meets MIL-STD-461 RS105 standards for NEMP testing. |
|
High Precision: Generates a minimum electric field of 50 kV/m, with higher fields available for smaller devices. |
|
Portable Design: Easy-to-move frame and compact setup for versatile placement. |
|
User-Friendly: Controlled via computer with RS232 and USB interfaces. |
|
Versatile Testing: Ideal for assessing EUTs up to appox. 4m x 2m x 1m. |
|
Robust Specifications: Quick rise time of 2.3 ns and pulse length of 23 ns, ensuring accurate and reliable results. |

|
Compliance: Meets MIL-STD-461 RS105 standards for NEMP testing. |
|
High Precision: Generates a minimum electric field of 50 kV/m, with higher fields available for smaller devices. |
|
Portable Design: Easy-to-move frame and compact setup for versatile placement. |
|
User-Friendly: Controlled via computer with RS232 and USB interfaces. |
|
Versatile Testing: Ideal for assessing EUTs up to appox. 5.5m x 3m x 1.5m. |
|
Robust Specifications: Quick rise time of 2.3 ns and pulse length of 23 ns, ensuring accurate and reliable results. |

|
Compliance: Meets MIL-STD-461 RS105 standards for NEMP testing. |
|
High Precision: Generates a minimum electric field of 50 kV/m, with higher fields available for smaller devices. |
|
Portable Design: Easy to move frame and compact design for versatile placement options |
|
User-Friendly: Controlled via computer with RS232 and USB interfaces. |
|
Versatile Testing: Ideal for assessing small electronics like printed circuit boards and subsystems. |
|
Robust Specifications: Quick rise time of 2.3 ns and pulse length of 23 ns, ensuring accurate and reliable results. |

|
MIL-STD-1275E Compliant: Dedicated design for conducted susceptibility testing on 28VDC circuits. |
|
Spike & Surge Testing: Handles spikes up to 260V / 2J and surges up to 200V / 470J. |
|
High Current Capability: 16A continuous or up to 400A with the optional DM400 decoupling diode module. |
|
Adjustable Waveforms: Configurable rise times, pulse durations, and voltages for precise test conditions. |
|
User-Friendly Control: Remote interface via RS232 or USB, with optional control software for automated testing. |
|
Enhance your EMC testing with the PG1275E Pulse Generator—precision, compliance, and versatility combined. |

|
MIL-STD-461 RS105 Compliance: Fully meets NEMP immunity testing standards. |
|
High Voltage Performance: Generates up to 50 kV/m fields with nanosecond rise times. |
|
Adaptable GTEM Design: Supports retrofitting of existing GTEM cells for NEMP testing. |
|
Automated Testing: Streamlined control, data collection, and report generation. |
|
No Environmental Disturbance: Safe operation without affecting nearby systems. |
|
Flexible Testing Capability: Accommodates small to medium-sized devices with a 110 cm septum height. |

|
HPD1000- Outdoor horizontally polarized NEMP simulator 10 m Height |
|---|
|
Standards Compliant: Meets MIL-STD-464C, MIL-STD-188-125-2, and IEC 61000-5-25 requirements. |
|
High Field Intensity: Generates up to 50 kV/m for effective NEMP survivability testing. |
|
Large Test Volume: Accommodates EUTs up to 10 x 5 x 5 meters. |
|
Automated Operation: Streamlined testing with automated control and report generation. |
|
Modular Design: Easily disconnectable generator for convenient long-term storage. |
|
Expert Support: Options for refurbishment and customization of existing systems. |

|
PGR-10KV-50R, 10kV, 5ns rise/fall, Repetitive high voltage pulser |
|---|
|
Adjustable High-Voltage Pulses – 1-10kV Configurable pulse voltage and duration for precise control. |
|
Upgradable to 20kV Pulses - 2 units can be put in series for a synchronized push-pull configuration to reach 20kV |
|
Nanosecond Pulse Precision – Ideal for plasma generation, electroporation, and pulsed electric fields (nsPEF). |
|
Built-in Monitoring & Safety Features – Automatic shutdown for overvoltage, short circuit, or HV disconnection. |
|
Quick-Connect HV Output – Easy integration with optional Montena connectors and HV dummy loads. |
|
Turnkey Solution – Compact, user-friendly, and reliable for high-voltage research and EMC applications. |
|
Applications: Plasma-activated water, Cold Plasma for air purification, Nanosecond pulsed electric field for stimulation of cells, Nanosecond pulsed electric fields in medical applications, Speed up Plant growth or germination |

|
PGR-30KV-50R, 30kV, 5ns rise/fall, Repetitive high voltage pulser |
|---|
|
Adjustable High-Voltage Pulses – 0.5-30kV Configurable pulse voltage and duration for precise control. |
|
Nanosecond Pulse Precision – Ideal for plasma generation, electroporation, and pulsed electric fields (nsPEF) |
|
Built-in Monitoring & Safety Features – Automatic shutdown for overvoltage, short circuit, or HV disconnection. |
|
Quick-Connect HV Output – Easy integration with optional Montena connectors and HV dummy loads. |
|
Turnkey Solution – Compact, user-friendly, and reliable for high-voltage research and EMC applications. |
|
Applications: Plasma-activated water, Cold Plasma for air purification, Nanosecond pulsed electric field for stimulation of cells, Nanosecond pulsed electric fields in medical applications, Speed up Plant growth or germination |

|
MIL-STD 461F CS106 Compliant: Ensures reliable military-standard testing. |
|
Flexible Configurations: Available as standalone (PG-CS106) or modular (M-CS106) units. |
|
High Performance: Delivers up to 500 V peak voltage and 8–100 A peak current. |
|
Precise Pulse Control: Supports 1–15 Hz repetition rates with swift rise and fall times. |
|
User-Friendly: Easy computer control via RS232 and USB interfaces. |
|
Compact & Portable: Lightweight design for both standalone (13 kg) and modular (1.2 kg) setups. |
|
Enhance your naval and industrial testing with the PG-CS106 Pulse Generator—precision, compliance, and versatility in one powerful solution. |

|
This generator has been designed as a trigger source for Marx generators and for trigatrons (triggered spark gaps). It can replace the obsolete PT55 trigger generator as mechanical dimensions and attachment points are the same. |
|
Solid-state switch |
|
High repetition rate |
|
Long lifetime |
|
No need of gas |
|
No need of external high voltage power supply |
|
Can be triggered by a 5 V digital signal or by fiber optic |

|
IP-DR250 & CJ-DR250 BCI Bulk Current Injection probe 4kHz - 400MHz, 500 Watts |
|---|
|
Frequency Range: 10 kHz to 400 MHz (extended: 4 kHz to 400 MHz with optional adapter) |
|
Power Handling: Up to 500 W CW (150 W – 60 min, 300 W – 30 min, 500 W – 15 min) |
|
Window Diameter: 43.8 mm |
|
Construction: Durable, shielded design with precision-machined housing |
|
Input Connector: Type N (Female) |

|
Special custom generator for high current DOW testing |
|
High Current Capability: Up to 300 A for direct injection and 75 A with the optional coupling clamp. |
|
Wide Frequency Range: Operates from 100 kHz to 55 MHz with 10 discrete frequencies (expandable to 10 kHz–100 MHz on request). |
|
Automation Ready: Fully computer-controlled with RS232 and USB interfaces for calibration, operation, and report generation. |
|
Efficient Testing: Single output connection eliminates reconnections, significantly reducing test time. |
|
Optimize your naval and industrial testing with the CS116 Damped Sinusoid Generator—precision and efficiency combined. |

|
Special custom generator for high current DOW testing |
|
High Current Capability: Up to CS116 +7dB for direct injection, 23 A with the optional coupling clamp. |
|
Wide Frequency Range: Operates from 10, 100 kHz 1, 10, 30, 100 MHz - expandable to 12 frequencies |
|
Automation Ready: Fully computer-controlled with RS232 and USB interfaces for calibration, operation, and report generation. |
|
Efficient Testing: Single output connection eliminates reconnections, significantly reducing test time. |
|
Optimize your naval and industrial testing with the CS116 Damped Sinusoid Generator—precision and efficiency combined. |

|
Tailored to Your Requirements – Custom-designed EMP and PCI solutions for specific voltage, waveform, and test conditions. |
|
Industry-Leading Fast Pulse Technology – Ensuring precision, repeatability, and compliance with global standards. |
|
Wide Voltage & Frequency Range – Custom solutions from 5 kV to over 500 kV, optimized for MIL-STD-188-125 and IEC 61000-4-25 testing. |
|
Seamless Integration & Automation – RS232, USB, and fiber optic control for efficient remote operation. |
|
Turnkey Testing & Data Acquisition – Compatible with Montena’s PULSELab software, ensuring real-time monitoring and analysis. |
|
Proven Global Expertise – Montena’s extensive EMP and PCI system portfolio guarantees reliable and compliant solutions for any application. |

|
MIL-STD-188-125-1/2 Compliant – Ensures precise pulse current injection (PCI) testing for EMP protection validation. |
|
High-Voltage Performance – Delivers up to 350kV pulses with a peak 5kA short-circuit current. |
|
Fast & Repeatable Pulses – Ultra-fast and 500-550 ns pulse duration for accurate testing. |
|
Fully Automated & Computer-Controlled – RS232 & USB interfaces enable seamless remote operation. |
|
Comprehensive Accessory Support – Compatible with current probes, CDNs, fiber optic links, and automation software for a complete test setup. |

|
MIL-STD-188-125-1/2 Compliant – Designed for precise EMP protection testing. |
|
High-Voltage Performance – 3.0 kV charging voltage with 260 A peak short-circuit current. |
|
Fast & Repeatable Pulses – and 3 – 5 ms pulse duration for accurate testing. |
|
Multi-Line Direct Coupling – 4 independent outputs for testing power, signal, and telecom lines. |
|
Fully Automated Control – RS232 & USB interfaces for seamless operation & remote testing. |
|
Complete Testing Solution – Compatible with current probes, CDNs, fiber optic links & optional automation software. |

|
MIL-STD-188-125-2 Compliant – Designed for pulse current injection (PCI) testing of antenna POE protective devices. |
|
Adjustable High-Voltage Pulses – 0.2 - 25 kV, 400A (CLP40K) for precise testing. |
|
Broad Frequency Coverage – Supports testing from 30 MHz up to 477.5 MHz with variable charge line plugs. |
|
Ultra-Fast Pulse Rise Time – and for high-speed transient testing. |
|
Direct Coaxial Coupling – No external coupling device required for efficient pulse injection. |
|
Automated Operation & Remote Control – RS232 & USB interfaces for seamless integration and monitoring. |
|
Complete Test Solution – Includes charge line plugs, current probes, fiber optic links, and optional Montena PULSELab software. |

|
MIL-STD-188-125-2 Compliant – Designed for pulse current injection (PCI) testing of antenna POE protective devices. |
|
Adjustable High-Voltage Pulses – 0.05 - 5 kV, 50Amps (CLP5K) for precise testing. |
|
Broad Frequency Coverage – Supports testing from 30 MHz up to 477.5 MHz with variable charge line plugs. |
|
Ultra-Fast Pulse Rise Time – and for high-speed transient testing. |
|
Direct Coaxial Coupling – No external coupling device required for efficient pulse injection. |
|
Automated Operation & Remote Control – RS232 & USB interfaces for seamless integration and monitoring. |
|
Complete Test Solution – Includes charge line plugs, current probes, fiber optic links, and optional Montena PULSELab software. |

|
High-Voltage Range: 20 V to 10 kV, positive polarity only. |
|
ECSS Compliant: Meets ECSS-E-ST-20-07C Rev.2 for space-grade ESD tests. |
|
Damped Oscillatory Waveform: Ensures accurate wire-coupled discharge simulations. |
|
Remote Control & Monitoring: Offers single shot, repetitive, or remote triggering with RS-232/USB. |
|
Safety & Reliability: Conforms to EN61010-1 and integrates a 24 Vdc safety loop |

|
High-Voltage Range: 20 V to 10 kV, positive polarity only. |
|
ECSS Compliant: Meets ECSS-E-ST-20-07C Rev.2 for space-grade ESD tests. |
|
Damped Oscillatory Waveform: Ensures accurate wire-coupled discharge simulations. |
|
Remote Control & Monitoring: Offers single shot, repetitive, or remote triggering with RS-232/USB. |
|
Safety & Reliability: Conforms to EN61010-1 and integrates a 24 Vdc safety loop |

|
MIL-STD-188-125 Compliant – Designed for HEMP Pulse Current Injection (PCI) testing. |
|
High-Current Pulse Generation – Delivers 50 A to 1.2 kA short-circuit current. |
|
Battery-Powered for Field Testing – Operates >24 hours without external power. |
|
Fast & Efficient Testing – Pulse rise time ≤ 20 ns, pulse duration 500-550 ns. |
|
USB Fiber Optic Control – Remote operation with full galvanic isolation for safety. |
|
Complete Test System Available – Includes couplers, current probes, decoupling networks. |
|
Rugged Transport Case – Portable & easy to deploy for on-site testing. |
|
Industry-Leading Accuracy – Precise data acquisition & error-free pulse measurement. |