Teledyne LeCroy WaveRunner 8000 - 500 MHz - 4 GHz Oscilloscope

Teledyne LeCroy WaveRunner 8000 - 500 MHz - 4 GHz Oscilloscope

Product Overview:

  • 500 MHz- 4 GHz bandwidths
  • Up to 40 GS/s sample rate
  • MAUI with OneTouch
    • Designed for touch
    • Built for simplicity
    • Made to solve
  • Advanced Tools
    • Jitter and Timing Analysis Capabilities
    • WaveScan – Search and Find
    • LabNotebook Documentation and Report Generation
    • History Mode – Waveform Playback
  • Optional Software Packages
    • Advanced Customization
    • Digital Filtering
    • Spectrum Analysis
    • Device and Switching Power Supply Analysis
    • Comprehensive set of serial data analysis, debug, validation and compliance tools
  • 16 digital channels with 1.25 GS/s
    • Analog and Digital Cross-Pattern Triggering
    • Digital Pattern Search and Find
    • Analog and Digital Timing Measurements
    • Logic Gate Emulation
    • Activity Indicators

 

More
MAUI – Superior User Experience

MAUI – Most Advanced User Interface was developed to put all the power and capabilities of the modern oscilloscope right at your fingertips. Designed for touch; all important oscilloscope controls are accessed through the intuitive touch screen. Built for simplicity; time saving shortcuts and intuitive dialogs simplify setup. Made to solve; a deep set of debug and analysis tools helps identify problems and find solutions quickly.

MAUI with OneTouch

The WaveRunner 8000 with MAUI OneTouch sets the standard for oscilloscope user experience by providing the most unique touch features on any oscilloscope. Common gestures are used to instinctively interact with the oscilloscope and dramatically reduce setup time. Convenience and efficiency are optimized - all common operations can be performed with one touch and do not require opening and closing of pop-up dialogs or menus.

Powerful, Deep Toolbox

The standard collection of math, measurement, debug, and documentation tools provides unsurpassed analysis capabilities. Application-specific packages enable streamlined debugging for common design/validation scenarios. The advanced customization option (XDEV) enables user-defined parameters and math functions providing unique and limitless analysis capability.

"M" Models for Maximum Sample Rate and Memory

An industry leading 40 GS/s sample rate allows for a detailed edge reconstruction even for signals with the fastest rise times. Long memory allows for maximum sample rate to be maintained in longer timebases. Deep memory of 128 Mpts is ideal for debugging long term behavior on high speed serial data buses.

Exceptional Serial Data Tools

A wide a variety of application packages are available to meet all serial data test challenges, ranging from automated compliance packages to flexible debug toolkits. A suite of protocol specific measurement and eye diagram packages are available to complement the industry’s most intuitive trigger and decode packages.

Powerful Mixed Signal Capabilities

Teledyne LeCroy’s WaveRunner 8000-MS mixed signal oscilloscope combines the high-performance analog channels of the WaveRunner 8000 with the flexibility of 16 digital inputs. In addition, the many triggering and decoding options turn the WaveRunner 8000-MS into an all-in-one analog, digital, serial debug machine.

Serial Trigger, Decode, Measure/Graph, and Eye Diagrams

Isolate events using the serial bus trigger and view color-coded protocol information on top of analog or digital waveforms. Timing and bus measurements allow quick and easy characterization of a serial data system. Serial (digital) data can be extracted and graphed to monitor system performance over time. Identify physical layer anomalies with eye diagram mask testing and mask failure locator.

LabNotebook

LabNotebook automatically saves all displayed waveforms, oscilloscope setup file, and a screen with a single button press, eliminating the need to navigate multiple menus to save all these files independently. Report files can be annotated and shared with colleagues to fully document all results.

Q-Scape Multi-tab Display Architecture

Unique Q-Scape multitab display architecture speeds your understanding of your design with 4x the display area. Acquired or calculated waveforms can be located on any of four different “tabbed” oscilloscope grid displays, with individually selectable grid styles available for each tab. Quickly move waveforms to different tabs through drag-and-drop.

Jitter and Timing Analysis Option

JITKIT makes it simple and easy to understand the basic system jitter performance of clock signals and clock-data activities, including period, half period, cycle-cycle, skew, amplitude, differential voltage crossing, slew rate, and a wide variety of other common jitter measurements.

XDEV Advanced Customization Option

With the XDEV option, third party programs can be completely integrated into the oscilloscope’s processing stream. Create customized math functions and parameters using C/C++, MATLAB, Excel, JScript or Visual Basic without ever leaving the oscilloscope application - and view the results directly on the oscilloscope, in real-time.

 

Main Specifications

Bandwidth 500 MHz - 4 GHz
Starting from $14,000
Standard Memory 32 Mpts - 128 Mpts (Interleaved)
Max Sampling Rate 20 GS/s - 40 GS/s
Input Channels 4
Resolution 8-bits